Adam-5000
Distributed Data Acquisition and Control System
Adam-6000 Smart Ethernet and Web I/O Modules
RS-232/422/485 to Ethernet/Wireless Serial Devices & Servers: ADAM-457x EKI-
Jump
down to ADAM-4000 Series Modules ...
I/O Modules
Communications
Modules
ADAM-4520 RS232 to RS422/485, ADAM-4510 Repeater, ADAM-4521 Addressable,
ADAM-4541 Fibre
Optic, ADAM-4561
USB,
Digital
I/O & Counters Ethernet
to serial
Software support Power Supplies Modbus
ADAM-4000
Series Data in Advantech Catalog
(Advantech Catalog)
For detailed
information on any ADAM-4000 Series item, use the above link.
User Manual for ADAM-4000 Series (.pdf, 9MB)
Advantech Support & Download page, Manuals, Resources Library (Advantech site, opens new Tab or Window)
RoHS
- Restriction of Hazardous Substances Info
on RoHS
AdamView Software for ADAM Modules PCLS-AdamView32
Plug-and-Play Connect with ADAM I/O series Download AdamView Software Brochure (.pdf file) Download
Evaluation version of ADAMView, Manual, FAQ (Advantech site) For demo purpose, the serial number is “0000000000”. Once you complete the data input of user name, company name and serial number.You are allowed to run ADAMView for 2 hours. Advantech
ADAMView provides a wide variety of graphical wizards, allowing users to quickly
create an intuitive user interface. |
|
Sensor
to computer or PLC interface for remote data acq & control
ADAM-4000
modules are compact, intelligent sensor-to- computer or PLC interface devices
with built-in microprocessors which provide signal conditioning, analog I/O, digital
I/O and comms all in an industrial hardened package. Can make stand alone, on/off
controllers.
Warranty period: 2 years.
ADAM
modules stand out because of their ability to accommodate multiple types and ranges
of analog input. You select the type and range remotely by issuing commands from
the host computer.
You may use just one type of unit for many different tasks,
greatly simplifying design and maintenance.
They translate analog data into one of the following formats: engineering units, % of FSR, two's complement or ohms. After the modules receive a request from the host, they send the data in the desired format over the RS-485 network.
The RS485 network can connect to a host computer using an ...
RS232 port with ADAM-4520
RS232 to RS485 Converter, or (these
links jump further down this page)
USB port using the ADAM-4561
USB to RS485 Converter, or
ditto
Ethernet port using ADAM-4571
Ethernet to RS485 Converter (this link jumps
to a different page, opens new tab or window)
|
|
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
User Manual for ADAM-4000 Series (.pdf, 9MB)
ADAM-4000 dimension diagrams: click here
Application
stories: click here (Sulfur Control Application for the Tire Industry)
(Advantech site)
and here
(Material Distribution System in Steel Plant)
and here
(Resonance Measurement in Large Construction Project)
and
here
(Wireless Water Level Monitoring and Control System)
Notes about the speed of an ADAM module system: click here
16-bit Integrating A/D converter with self calibration
3000VDC analog input isolation - Digital filter
Output data formats: engineering units, % of FSR, twos complement, or ohms. Data is sent in desired format when req. by host
Some analog modules contain two digital outputs and one digital input channel. They can drive solid state relays which in turn can control equipment.
Programmable
Alarm Output
Analog input modules include high and low alarm signalling. After every
A/D conversion, the digital value is compared with the high and low limit. The
module can change the state of a digital output depending on the result of this
comparison. This lets it perform On/Off control of a device independent of the
host PC.
Event Counter On-board event counter
can count to 65,535 transitions on the digital input.
The counter is read
and cleared by the host. Max sample rate: 50Hz.
Accessories
Included
Nylon DIN-rail mounting adaptor; SECC Panel mounting bracket. Plug-in
screw terminals.
PCLS-AdamView32
Data Acquisition and control software ... see near the top of this page.
Advantech
Catalog on ADAM-4000 Series Modules (Advantech Catalog Chapter)
For
detailed information on any ADAM-4000 Series item, use the above link.
Analog Input & Output ModulesSee
also ADAM-4015 RTD Module, 6 ch and | |||||||
|
ADAM | 4011 & 4011D | 4012 | 4013 |
4016 | 4017
8 ch |
4018 8 ch |
|
|
Input Types |
Thermocouple |
V & I Input |
RTD Input |
Strain Gauge Module Analog | 8
channels: ADAM-4017+ has 8 diffl
inputs, & |
8 channels thermo-couple & ADAM-4018+
has 8 diffl inputs, |
|
|
Dig Out | 2, open collector, can sink 30mA | None |
4, open collector, |
None | None | ||
| Dig Inp |
1 in; event counter | 1; event cntr | None |
None | None |
None | |
|
Features in common: Output: RS485; Baud Rates: 1200, 2400, 4800, 9600, 19,200 bps; Dim: 112 x 60 x 25 mm; Oper. temp 0°C to 70°C. Power Supply: +10 to 30VDC, | |||||||
| Isolation |
3000V DC | 3000V DC |
3000V DC | 3000V DC |
3000V DC | 3000V DC | |
| Watchdog |
Watchdog | Watchdog |
Watchdog |
|
Watchdog | Watchdog | |
| Conversion rate: 10 samples/sec;
| Analog Output: 1ch, 0-10V, with 30mA drive, 3KV isolation |
10 sa/sec, 13Hz, 0.1% or better, |
6 diffl inputs, Note:
| ||||
|
|
|
|
|
|
| ||
A Windows PC is generally required to configure the
modules initially, using the software supplied with the module.
Adam modules
can be controlled using simple ASCII commands over the serial link.
An ADAM-4520
RS-232 to RS-422/485 converter may be needed, unless your PC has an RS-422/485
port.
Once this initial configuration has been done, the module stores the
configuration in its internal non-volatile memory.
You can then connect any
serial device to it and use the simple ASCII commands to read data.
Independant configuration of channels, Pt, Ni, Balco, burn-out detect.
ADAM-4017 & ADAM-4017+ can be controlled using simple ASCII commands over the serial link, similar to the other Adam modules.
For example, to read analog data from input 3 on ADAM module number 01, simply send #013 to the module. The complete set of commands is described in the ADAM-4000 series operation manual.
Version –D2 is the current model which
has a higher input impedance (2M versus 200k for the -D version).
The –D2
is the only one available now. It supports ±10V inputs. Prices:
see below
for users needing various analog input signals
with various types of analog input: V, mV, mA, or thermocouple signals.
8
differential analog inputs. ±100mV, ±500mV, ±1V, ±2.5V,
±5V, ±10V, ±20 mA. Thermocouple types: J, K, T, E,
R, S, B
multi-ch/multi-range mechanism
Isolation voltage: 3000 VDC, overvoltage
to ±35VDC, Zin 20Mohms, Bandwidth 13.1Hz@50HZ,
Acc 0.1% of voltage
input, Zero drift 30µV/°C, Span drift
±25ppm/°C, CMR @50/60hz 92db min.,
Burn-out: upscale for T/C input
Built-in watchdog timer. Power:
unregulated 10 to 30VDC 1.2W Data
0 to 20mA, 4 to 20mA, 0-10 V.
Effective resolution: 12-bit. Current load resistor for current output:
0 to 500 ohms
Programmable output slope: 0.01 to 10,000 V/s (mA/sec).
No digital IO. 3000V DC. Watchdog.
Accuracy: ±0.1% of FSR for current
output, ±0.2% of FSR for voltage output
Resolution 0.025% FSR.
Zero Drift: Vout: ±30µV/°C
Iout: ±0.2µA/°C. Analog readback.
Output: 0-10 V, ±10V, 0 to 20mA, 4 to 20mA, 4 channels, alarm settings.
See also ADAM-4016 above, which has an analog output.
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
The ADAM-4100 series modules are compact, versatile sensor-to-computer
interface units designed for reliable operation in harsh environments.
Their
built-in microprocessors, encased in rugged industrial-grade ABS plastic, independently
provide intelligent signal conditioning, analog I/O, digital I/O, LED data display,
and an address mode with a user-friendly design for convenient address reading.
8 differential and independent
configuration channels
Broader Operating Temperature Range
Higher
Noise Immunity: 1 kV surge protection on power inputs, 3 kV EFT, and 8 kV ESD
protection
Broader Power Input Range: +10 ~ +48VDC
LED dsiplay allows
to monitor the status address settings
Supports 200 VDC Hi common mode voltage
Supports unipolar and bipolar input
Supports +/- 15 V input range
Supports
filter auto-turning or filter-out 50 Hz / 60 Hz
Online Firmware Update Data
(.pdf)
8 differential
& independent thermocouple configuration channels
Broader Operating
Temperature Range
Higher Noise Immunity: 1 kV surge protection on power inputs,
3 kV EFT, and 8 kV ESD protection
Broader Power Input Range: +10~+48 VDC
Supports
filter auto-tuning or filter out 50 Hz / 60 Hz
LED display allows to monitor
the status address settings
Online Firmware Update Data
(.pdf)
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
Analog
Modules: (see further down for Digital I/O Modules)
ADAM-4011-D2 Thermocouple Input Module $227
7/09
ADAM-4012-DE Analog Input Module (mV,V,mA)Rev.D1 CE $224
ADAM-4013-DE
RTD Input Module $206
ADAM-4015-BE 6-Ch RTD Module w/
Modbus $399
ADAM-4015T-AE 6-Ch Thermister Input Module w/
Modbus $398
ADAM-4016-A2E AI/Output Module $260
ADAM-4017+-CE 8-Ch
AI Module w/ Modbus $318
ADAM-4017-D2E 8-Ch AI
Module $236
ADAM-4018+-BE 8-Ch Thermocouple Input Module w/
Modbus $337
ADAM-4018-D2E 8-Ch Thermocouple Input Module $249
ADAM-4019+-AE
8-Channel Universal Analog Input Module $399
ADAM-4019-AE 8-Ch Universal AI
Module $431
ADAM-4021-DE AO Module $224
ADAM-4022T-AE Serial Based Dual
Loop PID Controller $424
ADAM-4024-B1E 4-Ch AO Module w/
Modbus $324
ADAM-4117-AE 8-Ch AI Module $318+GST 7/09
ADAM-4118-AE 8-Ch Thermocouple Input Module $337
ADAM-4050 Series Prices: Scroll down a little.
Some modules can be configured for Modbus RTU protocol. See below for more Modbus information
The E at the end of the part number signifies RoHS compliance.
The -A, -D or -D2 after the part number is a revision number and can be ignored when ordering
AdamView Software for Adam Modules... see near top of this page
Digital I/O & Counter Modules | |
ADAM-4050 Digital I/O | 7 inputs with pull-up resistors to
+5V, and |
ADAM-4051 Digital Input |
16 digital inputs, digital LED indicator |
ADAM-4052 Digital Input | Isolated to
5KVrms, Input range: 3.5 to 30VDC. |
ADAM-4053 Digital Input, 16 Ch | Input levels: Dry Contact:
0: close to gnd, 1: Open. |
ADAM-4055 Digital I/O |
8 inputs Input Voltage level: 10~50 VDC |
ADAM-4060 Relay Output Module |
4-channel relay: 2 form A, 2 form C (500VAC isolation) |
| |
|
ADAM-4080 Counter & Frequency Module | 2
ch, 5Hz-50KHz max, 32-bit (4 million counts). |
| ADAM-4080D Counter & Frequency,
|
2 ch, 5Hz-50KHz max, 32-bit (4 million counts), |
7 input channels and 8 output channels
Broader Operating
Temperature Range
Higher Noise Immunity: 1 kV surge protection on power inputs,
3 kV EFT, and 8 kV ESD protection
Broader Power Input Range: +10 ~ +48 VDC
LED display allows to monitor the status address settings
Digital Filter
Function
DI channels can be used as 1 kVGz counters
Over current/ short
circuit protection
DO channels support pulse output function Data
on ADAM-4150 (.pdf)
8
Form A output channels
Broader Operating Temperature Range
Higher Noise
Immunity: 1 kV surge protection on power inputs, 3 kV EFT, and 8 kV ESD Protection
Broader Power Input Range: +10 ~ +48 VDC
LED display allows to monitor
the status address settings
DO channels support pulse output function
B version ADAM-40xx...-B
series modules can be configured for Modbus
RTU protocol.
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
Prices:
ADAM-4050-DE 15-Ch DI/O Module $137+GST 7/09
ADAM-4051-BE 16-Ch Isolated DI Module w/ LED w/
Modbus $175
ADAM-4052-BE Isolated Digital Input Module
$137
ADAM-4053-AE 16-Ch Isolated DI Module $156
ADAM-4055-BE
16-Ch Isolated DI/DO Module w/ LED w/
Modbus $175
ADAM-4056S-AE 12-Ch Sink Type Isolated DO Module
w/ Modbus $162
ADAM-4056SO-AE 12-Ch Source Type
Isolated DO Module w/ Modbus $187
ADAM-4060-DE
4-Ch Relay Output Module $169
ADAM-4068-BE 8-Ch
Relay Output Module w/ Modbus $200
ADAM-4069-AE
8-Ch Power Relay Output Module w/ Modbus
$255
ADAM-4080-DE Counter/Frequency Module $224
ADAM-4150-AE
15-Ch DI/O Module $197+GST
7/09
ADAM-4168-AE
8-Ch Relay Output Module $200
Some modules can be configured for Modbus RTU protocol. See below for more Modbus information
The
E at the end of the part number signifies RoHS compliance.
The -A, -D or -D2 after the part number is a revision number and can be ignored when ordering
AdamView Software for Adam Modules... see near top of this page
|
DR-75-24 DIN Rail Mounting | 24VDC 75 watt power supply
Vout: +24VDC ±1%, 3.2 Amps, -10 to 60°C, 55.5x125.2x100mm DR75-24 |
![]() |
| S-25-12 | 12VDC 25 watt power supply
Vout: +12VDC ±10%, 2.1 Amps. 0 to 50°C, 99deep x97x36mm
S25-12 zcl | |
|
S-60-24 Panel Mounting |
24VDC 60 watt power supply Vout: +24VDC ±10%, 3 A. S60-24
zcl | ![]() |
| DIN-60 DIN Rail Mount | DIN
rail mount fitting for S-60-24 above $25+GST
zcl | |
|
|
| |
| S-100-24 | 24VDC 100 watt
power supply. 199x98x38mm $125+GST
zcl | |
| DIN-100 DIN Rail Mount | DIN rail mount fitting for S-100-24 $28+GST |
ADAM-4500 has an 80188 CPU, 234KB SRAM for running programs,
256KB Flash ROM for program files (170KB free),
built-in ROM-DOS (sim
to MS-DOS). Standard PC programs can run in this module.
COM1: RS232/485,
COM2: RS485 with automatic data flow control for other ADAM modules,
a third
RS232 port for program download, Real time clock, Watchdog timer.
Download utility incl. 10-30VDC unreg. 2W. -10 to +70°C
10/100Base-T Ethernet interface
Email alarm function
Built-in
web server
Built-in FTP server and client
Supports versatile I/O modules
Full
functions of standard TCP and UDP sockets
Optional 4 digit 7-segment LED display
Supports
Modbus/RTU and Modbus/TCP function libraries
1.5 MB Flash ROM/640 KB SRAM
4
serial ports available
Integrates all operations in Windows utility
Data
on ADAM-4501, -4502: see page 15-12 in
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
then choose the second link Chapter 15
Prices:
ADAM-4500-AE PC-Based
Communication Controller $324+GST 7/09
ADAM-4501-AE Ethernet-enabled Comm. Controller with 8 DI/O $437
ADAM-4501D-AE Ethernet-enabled Comm. Controller with 8 DI/O $512
With
its modular design, ADAM-4502 has all the same functionality as ADAM-4501, but
provides different I/O options.
The ADAM-4502 provides one Ethernet interface
and 4 serial ports module,
but also features 1 analog input, 1 analog output,
2 digital inputs and 2 digital outputs.
This versatility allows users to implement
rich interfaces for different applications.
10/100Base-T(X) Ethernet interface
Email
alarm function
Built-in web server
Built-in FTP server and client
Supports
functionally versatile I/O modules
Full functions of standard TCP and UDP sockets
Supports
Modbus/RTU and Modbus/TCP function libraries
1.5 MB Flash ROM/640 KB SRAM
4
serial ports
Integrated all operations in Windows utility
Data
on ADAM-4502 (pdf file, opens in new tab or window)
ADAM-4502-AE Ethernet-enabled Comm Controller 1AI/1AO/2DI/2DO $530+GST 5/10
Communications ModulesPower required: 10 to 30 VDC unregulated. DIN rail or panel mounting. Plug-in screw terminals.Isolation to 3000VDC where applicable. RS485 lines have automatic flow control, and transient protection | |
ADAM-4520 | Converter
Module, supports up to 32 Adam Modules on RS485 (2-wire) or RS422 (4-wire).
Up to 115Kbps. RTS handshake. Isolation: 3000VDC. Transient
suppression on RS485 lines. LED Indicator: data activity:Yellow: RS232 in, Red: RS232 out, Orange: both Supports up to 32 Adam Modules, or other RS485 devices. Connectors: RS232: DB9F at the top; LED on
the ADAM-4520: Green light blinking: Transmitting data ADAM-4520-D2E Isolated RS-232 toRS-422/485
converter E at the end of the part no. indicates RoHS compliance RS232 Cables for ADAM-4520:
DB9M to DB9F (ADAM-4520 to PC Com port) lhb
See also Cordless Serial Adaptor - replace serial cables with Bluetooth wireless (opens new window) RS232 to RS232 Isolator RS232/RS232 IsolatorRS232 to RS232 with isolation can be acheived by using two ADAM-4520
back to back using the RS422 connection between them. Each ADAM-4520 needs unregulated power supply
10 to 30 VDC, e.g. Mains Adaptor see above |
ADAM-4522 | Non-isolated version of above. Not stocked in Australia... 2-3 weeks delivery. |
ADAM-4510 | RS485/422 Repeater allows addition of 32 modules to the network and extends the network for another 1.2km. Transient suppression on RS-485 data lines. Up to 115Kbps. |
ADAM-4510S |
As above, isolated to 3KV, Transient suppression on RS-485 data lines |
ADAM-4521 | Used to interface an RS232 device to an RS485 network. Addressable, 1000VDC isol., watchdog timer, transient suppression. Auto senses direction of flow of data, no handshaking signals. Handles different baud rates between the two sides. DB9F on RS232 side. |
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
AdamView Software for Adam Modules... see near top of this page
A solution for surge protection of
voltage signals in industrial control systems, the ADAM-4914V is now available.
With four channels & protection up to 4,000 volts, it saves space and shields
sensitive control system equipment.
To offer a more affordable solution for surge protection of voltage signals in industrial control systems, the ADAM-4914V was released today by Advantech. With four channels and protection up to 4,000 volts, this compact surge protector saves space and shields sensitive control system equipment.
Most factories today are facing increasingly complex wiring systems where high voltages are common. Interference from these high voltage wires can cause serious damage to control systems.
Instead of a low voltage signal,
a control system could receive surges of up to 4,000 volts. The result of such
a surge is usually expensive, as all the components in the control system may
need to be replaced. The ADAM-4914V is sensible and cost-effective insurance against
these surge voltages.
Discharge Voltage:
18V Between Lines 350V
Line to Ground
Max. Surge Voltage: 23V Between Lines
4,000V Line to Ground
he compact design of the ADAM's family saves space, and has flexible mounting options like: wall, panel, piggyback, cabinets and of course, DIN rails. While most surge protectors in the market only offer one channel, Advantech offers four. This means less space is required, and the cost of protecting multiple channels is reduced.
The ADAM-4914V can be used for thermocouple or other voltage-based signals and is recommended for factories with high voltage wiring systems that may interfere with the voltage signals of a control system.
ADAM-4914V-AE 4-Ch Surge Protection Module: $175+GST 7/09
Fibre OpticFiber optics are the perfect solution for applications where the transmission medium must be protected from electrical exposure, lighting, atmospheric conditions or chemical corrosion. Single
Mode: A fiber with a small core, only a few times the wavelength of light
transmitted, that only allows one mode of light to propagate. Commonly used with
laser sources for high speed, long distance links. ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog) | |
|
See also next item: Opt-ST-05 Prices: scroll down a little |
| OPT-ST-05 |
62.5/25um, 5-meter fibre optic cable, |
|
ADAM-4542+ converts single-mode fibre optic signals to RS-232/422/485 serial
signals. The ADAM-4542+ is specially designed to
link various machinery equipped with RS-232/422/485 communication ports (such
as computer systems or manufacturing machines). Download user manual for ADAM-4542+ Prices: scroll down a little Alloy Serial to Fibre ConvertersAlloy RS-C200ST or SC ST
or SC Fibre Connector Alloy RS-C230SC-4 SPC Self
Powering Cable (32cm) for Converters. PS/2 connector The RS-C230xx
range provides media conversion from RS-232, RS-422 or RS-485 serial signalling
to multimode or single mode fibre. Other models also cover multi-mode fibre (similar to ADAM-4541), ST fibre connectors instead of SC, DB9 serial instead of screw terminals. Alloy Data (.pdf file) Note that the power supply requirement is 5V DC on Alloy modules, as against 10-30V DC for the ADAMs. However the Alloy modules do come with a 5V plug pack. Other products in the Alloy catalogue e.g. serial cards. |
M15073 RS232 to Fibre OpticM15074 RS422 to Fibre Optic |
M15073 Converter RS232 to Fibre Optic with RTS/CTS M15074 Converter RS422 to Fibre Optic Data
on both: click here (jumps to different page) |
| ADAM-4561
1-port Isolated USB to RS-232/422/485 converter |
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
AdamView Software for Adam Modules... see near top of this page
ADAM-4510-DE
RS-422/485 repeater Rev.DE $143+GST
7/09
ADAM-4510I-AE Wide-Temp
RS-422/RS-485 Repeater $224
ADAM-4510S-DE RS-422/RS-485
repeater with isolation Rev. DE $187
ADAM-4520-D2E RS-232
to RS-422/485 converter w/ iso. Rev. D2E $118 Qty 5-9:
$108, Qty 10+: $103.74
ADAM-4520I-AE Wide-Temp
RS-232 to RS-422/485 Converter $162
ADAM-4521-AE Addressable
RS-232 to RS-485/422 Converter $236
ADAM-4522-AE RS-232
to RS-422/485 converter Rev. AE $107
ADAM-4541-AE Fiber
Optic To RS-232/422/485 Converter AE $293
ADAM-4542+-AE Fiber
Optic to RS-232/422/485 Converter Rev.AE $567
ADAM-4561-AE 1-port
Isolated USB to RS-232/422/485 Converter $175
ADAM-4562-AE 1
port isolated USB to RS232 converter module $131
The E at the end of
the part number signifies RoHS compliance.
The -A, -D or -D2 after the part number is a revision number and can be ignored when ordering.
Ethernet to RS232/RS422/RS485Jump to new page on Ethernet to RS232/RS422/RS485 ADAM-4570 -4571, ADAM-4577 -4579 |
AdamView Software for Adam Modules... see near top of this page
Transmission speed: 300 bps to 115.2 kbps Data on ADAM-4572 (Advantech Catalog Chapter 7)
ADAM-4572-AE Ethernet
to Modbus Data Gateway $377+GST 7/09
ADAM-4914V-AE 4-Ch Surge Protection Module: see above
The E at the end of the part number signifies RoHS compliance.
The -A, -D or -D2 after the part number is a revision number and can be ignored when ordering.
EDG-4504 is an industrial-strength
network-based serial device server
for connecting 4 RS-232/422/485 devices
(EDG-4504),
such as CNCs, PLCs, scales, and scanners, directly to a TCP/IP
network (Ethernet or Internet).
Compared to similar devices on the market,
it has the lowest cost, best performance, and most advanced features.
Both
10 Mbps and 100 Mbps Ethernet connections are supported, providing higher bandwidth,
lower traffic impact, and more layout
flexibility.
EDG-4504 has a professional
cabin design, with Tx/Rx LEDs for all ports on the front panel,
and
all of the DB9 and RJ45 phone jack connectors.
This makes EDG Series suitable
for multi-task environment, and simplifies its operation, maintenance, and
administration.
Similar in function to ADAM-4570 (needs Advantech drivers).
EDG-4504-AE 4-port Serial to Ethernet Data Gateway
$452+GST 7/09
EDG-6528-AE 8-port 10/100 Mbps
Industrial Switch $453
EDG-6528I-AE 8-port Wide Operating Temp. Industrial
Switch $629
EDG-6528L-AE 8-port 10/100 Mbps Unmanaged Switch $274
EDGE-300E
Quad-band EDGE USB dongle $190
ADAM-4000
Series Data in Advantech Catalog (Advantech Catalog)
For
detailed information on any ADAM-4000 Series item, use the above link.
These modules are ideally suited for existing or new Modbus networks, providing a simple, effective, low cost solution for monitoring or control applications. Diagrams: click here
Integration with Operator Interface Panel
Benefits:
Compatible with any Operator Interface Panel
Easy
I/O mapping to pre-built graphic display
Flexible network capacity
based on remote architecture
Integration with SCADA Server
Benefits:
Compatible to most HMI software
Easy to build &
maintain in I/O database
Flexible network capacity for both Serial
and Ethernet networking.
Integration with RTU/DCS/PLC Control System
Benefits:
Easy integration with RTU/DCS/PLC Control System
A cost-effective remote I/O solution for system expansion requirements
Suitable for application in widely-distributed monitoring & control
systems
The ADAM-5511 is a PC-based programmable controller with a Modbus interface,
integrating field signal (AI/O, DI/O, Counter, and Serial Communication) for data
acquisition and control. See ADAM-5000
page.
On the other hand, the ADAM-4572 is a serial-to-Ethernet
data gateway with a Modbus protocol,
enabling field status from the ADAM-5511
up to Enterprise data.
Data
on Modbus Data Gateway (Advantech site) Data
on ADAM-4572 (Advantech Catalog Chapter 7)
| ADAM-4572
|
While ModBus is becoming the de facto open standard for industrial networking
protocol, With these merits for a true
communication server between Ethernet and ModBus, the ADAM-4572 can be your best
choice to integrate Ethernet and ModBus network within your factory for better
network integration and resource sharing. Data
on ADAM-4572 (Advantech Catalog Chapter 7) |
ADAM-4000-UTIL is included
with the modules. Easy-to-use menu-driven utility software, including a terminal
emulation program, makes configuration and calibration a snap.
Writing application
programs with this software is simple, and you can learn the basics in just a
few minutes.
PCLS-DLL-A ADAM Windows DLL drivers are also included, see below.
ADAM modules are
supported by:
ADAMView Software, see top
of this page
Included with ADAM modules.
This driver lets you control ADAM modules
from any programming language that works with DLLs, including Visual Basic, Microsoft
C++, Turbo C++ and Turbo Pascal. The driver package includes a VBX custom control
for Visual basic and an easy to use Windows setup program with terminal emulation.
The driver works with COM ports 1 to 4. It supports all ADAM functions except for the ADAM-4080D's counter (Counter/Frequency module).
Programming Example (BASIC)
If the command"#05" is sent to a network of ADAM modules, the module whose address is 05H will respond with a reading, for example: "+4.834".
OPEN "COM1: 9600, N, 8, 1,RS ,CS ,CD ,DS" AS #1
CMD$ = "%2333324100600"
PRINT #1, CMD$
'ADAM-4011
is now configured to address 24H, T-type thermocouple input, 9600bps, eng. unit
data format'
CMD$="#24"
PRINT #1, CMD$ 'Read analog input data'
RESULT$ = INPUT$(5,#1)
PRINT "Temperature = ",RESULT$
CLOSE: END