Converts
from RS-232 to RS-485 or RS-422.
zmx
lhl lhb
Modes:
RS422 mode: Point to point (2 devices), with two twisted pairs.
RS485 mode: Multidrop on one twisted pair cable,
Simplex: when any device transmits, the
others receive only
IC485S & IC485SN do not have isolation, so are suitable for short
distances..
In RS485 mode, data transmission direction must be controlled by the
RTS Signal (i.e. not automatic).
For Automatic direction
control see J995X or ADAM-4520
DCE/DTE Selectable
Point to Point, Multidrop, and Simplex/Duplex Link Selectable
Four Wire Full Duplex / Two Wire Half Duplex
Compact Size
Monitor Mode on IC-485S
Data transfer can take place at up to 1200 metres over four or two wire cable
for full or half duplex, respectively.
In RS485 (2-wire) mode up to 32 receivers can be set up in a multidrop installation,
making for a cost effective network configuration.
The RS485 side remains in receive mode until switched to transmit mode by Request
to Send (RTS) on the RS232 side.
IC-485S and IC-485SN can obtain power from the RS232 port.
For better line driving capability,
Mains Adaptor is included with IC-485S and IC-485SI, but
not with IC-485SN.
(9VDC, 200mA, with small DC cylindrical plug, 3.5mm dia.,
centre +ve)
IC-485SI (isolated version) requires the mains adaptor to be used.
Warranty: 12 months. ATEN Download
IC-485S Manual: click here (.pdf file)
|
Function |
IC-485S |
IC-485SI Isolated |
IC-485SN | |
| Monitor configuration support | Signal & power isolation | |||
| Connectors | RS-232 DB-25 female | same | same | |
| RS-485
/ RS-422 four terminal block | same | same | ||
| RJ-11 | Grounding
tab (no RJ-11) | RJ-11 | ||
| Switches | SW1 | DCE, DTE, Monitor Mode, see below | DCE, DTE | DCE, DTE |
|
RTS control of transmit | 1.
TxON, RxON Use in point to point mode with two devices only (RS422), or multidrop, with one device only with this setting, and others set to Tx-RTS, RxON (sw position 3) | same | same | |
| 2. Tx-RTS, Rx-notRTS (multidrop mode) | same | same | ||
| 3. Tx-RTS, RxON (multidrop mode) | same | TxDTR/RTS, RxDSR/ON | ||
| Data Rate | Up to 100 Kbps Under 1200m [4000'] | same | same | |
| Cable Length | 1200 m [4000'] (Max.) | same | same | |
| Power Consumption | Can
run without the mains adaptor; mains adaptor gives better line driving capability (DC 9V 200mA, centre +ve, 3.5mm cylindrical plug). Mains adaptor is supplied. | Mains adaptor is provided and must be used. |
Non-powered operation possible. Mains adaptor not included. Power skt is provided for optional power. | |
| Housing | Plastic | same | same | |
| Weight | 60 g | same | same | |
| Dimensions (L x W x H) | 74.5 x 54 x 18.5 mm | same | same | |
|
IC-485S Download IC-485S Manual (.pdf file) |
Not available. |
IC-485SN | ||
| The User Manual has connection
diagram for all modes | ||||
DCE/DTE Switch:
DCE: Data Communication Equipment, pin 3 Tx, pin 5 active
DTE: Data Terminal Equipment, pin
2 Tx, pin 4 active)
pins 2 & 3, and 4 & 5 are reversed by the switch, pin
7 is common
Monitor Mode in IC-485S:
The R+ and R- terminals reflect data to pin 3 of the RS232 port (DB25F)
The T+ and T- terminals reflect data to pin 2 of the RS232 port (DB25F)
The User Manual has connection diagram for all modes.