Go up one level to Datataker main page

Analog
ChannelsA basic concept of the dataTaker data logger is that analog inputs can be used with more than one type of sensor, without needing additional input modules.
The dataTaker "analog channel" is a group of 4 terminals that can be used in many combinations.
DT80 has five 4 wire
(4 terminal) channels,
DT81 has one "
DT85 has sixteen "
These
allow sensors and signals based on voltage, current, resistance and frequency
to be measured.
These are the fundamental signals output by most sensors.
It is not necessary to use all four terminals on each channel.
Each of these analog channels can be connected to between 1 and 3 sensors or signals, depending on the requirements of that sensor or signal type.
Refer to the user manual for detailed connection information.

FAQ on DT80, DT81 & DT85 (and G versions) (opens new tab or window)
The DT81 has been discontinued, in favour of the new DT82E Environmental logger.
Fast logger   DT800 DT80 DT82E DT85 DT80G
has Vibrating Wire Sensor Support DT85G has Vibrating
Wire Sensor Support Analog Channels: 2
analog input channels Each channel is independent and supports:
one isolated 3-wire or 4-wire input, or   DT800 DT80 DT82E DT85 2-wire
isolated (see note above), 24 10 4 32
Single Ended (ground ref) 42 15 6 48 Analog
Input Expandable No Yes, to 300 * No expansion Yes, to 800 * Multiplexer
Type: SS Relay Relay Relay Analog Input Range ±13 VAC / VDC ±30V ±30V ±30V
Overall range is ±30Vdc, however
Overvoltage protection ±40V +/-
35 VDC +/-
35 VDC +/-
35 VDC Common Mode Range ±13V or ±3.5V or ±3.5V or ±3.5V or Max
Samples per second (analog) 200 Sa/sec 25
Sa/sec 25
Sa/sec 25
Sa/sec Built-in
Data Points Storage 130,000 expandable 10
million 10 million 10 million   DT800 DT80 DT82E DT85 Digital
& Counter Inputs 16 8 bi-directional
channels, as follows: 4
bi-directional channels, as follows: 12 Counter
Channels Low
Speed Counters Dedicated
Counter Inputs Input
type: 2 logic level inputs (max ±30V), Low
Speed Counters Dedicated
Counter Inputs Input type:
2 logic level inputs (max ±30V), and DT800 DT80 DT82E DT85 SDI-12
SDI-12
Info Yes 4 SDI-12 inputs, shared with digital
channels. Each input can support multiple SDI-12 sensors. 1 SDI-12 input, shared with a digital
channel Serial
Sensor Channel RS232 1 2 1 2 Isolated Communications with host
computer An RS232 port, 300 to
115200 baud, a Host RS232 Port, Speed:
300 to 115200 baud (57,600 default) Generic
Serial Sensor USB
Port Interface: USB 1.1 (virtual COM port) No Yes No Yes Ethernet
Port 10BaseT
Protocols: TCP/IP (UDP, FTP) 10BaseT
(10Mbps) Protocol: TCP/IP Web
Interface Yes Web
Server Yes Display built in No Yes LCD, 2 line
by 16 characters, backlight. Yes Panel Mount Display option No No No No Resolution: 14 to 18 bits 18 bit 18 bit 18 bit Volts.
Current, 4-20ma, Resistance Yes Yes Yes Yes Frequency, Period Yes Yes Yes Yes Thermocouple support 11 types 11 types 11 types 11 types RTD
support (Pt, Cu, Ni) Yes Yes Yes Yes Bridges, Strain Gauge support Yes Yes Yes Yes Thermistor Arrays: * Resistance
range: <10kohms, <20kohms with parallel resistor Yes * Yes. Resistance
range: <10kohms ** Vibrating
Wire support No DT80G
has Vibrating Wire Sensor Support No DT85G
has Vibrating Wire Sensor Support DT800 DT80 DT82E DT85 Digital
channels Input/Output shared 8 shared I/O 8 shared I/O 4 shared I/O 8 shared I/O Digital
Inputs, not shared, logic levl 8 Digital
Output Ch types 8
shared with bi-directional channels, open-drain FET, +30V, 100mA 4 open drain FET, 3
open drain FET, 4 open drain FET, Relay
output, latching, No 1 relay contact 1 relay contact 1 relay contact Counters,
slow (<10Hz) 14 8 shared with DI 4 shared with DI 8 shared with DI Counters:
2 4
or 2 4
or 1 4
or 2 Counter Input Ch types
16, shared with digital I/O channels Speed: Channels 1- 6 100Hz
(3Hz in Sleep Mode) Channels 7- 8 10kHz (1kHz in Sleep Mode) Channels 9-16 100Hz
(3Hz in Sleep Mode) 2
logic level inputs 2
logic level inputs 2
logic level inputs Counter Channel Expansion No No No No Supports Datataker network (older
models DT50, DT500, etc, have this) No
No No No Internal Battery 12V (2.2AHr) lead acid gel cell 6VDC (1.2AH) 6VDC (1.2AH) 6VDC (4AH) Dimensions
260 x 110 x 90mm 180
x 137 x 65mm 180
x 137 x 65mm 300
x 137 x 65mm DT800 DT80 DT82E DT85
Datataker
Comparison
Differential
(4-wire, double-ended)
12
5
two isolated 2-wire inputs, or
three
common referenced 2-wire inputs.
The following maximums apply: Two wire with
common reference terminal: 6
Two wire isolated: 4
Three and four wire
isolated: 2
16
Expandable
to
* Expansion requires CEM20
NOTE:
The DT80, DT81, and the DT85 loggers have different characteristics related to
isolation.
They use "Dual channel" isolation technology
to allow two isolated two wire inputs on the same channel
as well as disconnecting
AGND (EXT#) when not in use.
expandable to
not expandable
expandable to 200 *
not expandable
expandable to 600 *
with one shared terminal
(with no differential)
(with no differential)
(with no differential)
* Expansion requires CEM20
SS (Solid State) or Relay Contacts
the default range for most measurement types is <±3Vdc.
The higher ±30Vdc
range is only available if the internal attenuation is on.
By default all
channel types except HV (high voltage) and AS (analog state) channel types have
attenuation off.
Lightning protection: secondary, via ±30V varistors
–2V to 22V selectable
±35V on 30V range
±35V on 30V range
±35V on 30V range
Burst
mode: 100kSa/sec
dual battery
backed SRAM
also has USB memory stick support
Input Type:
8
logic level (max 20/30V)
Output Type:
4
with open drain
FET(max:
30V, 100mA),
4 with logic output.
Relay
Output: 1 latching relay,
contacts
(max: 30Vdc, 1A)
Input Type:
4
logic level (max 20/30V)
Output Type:
3
with open drain
FET(max:
30V, 100mA),
1 with logic output.
Relay
Output: 1 latching relay,
contacts
(max: 30Vdc, 1A)
8 counters shared with digital inputs.
Low speed counters
do not function in sleep mode.
Size: 32 bit
Max Count rate: 10 Hz
4 high speed or 2 phase encoder (quadrature) inputs, size:
32 bit Max Count rate: 10 kHz
2 sensitive inputs (10mV) for magnetic
pick-ups (max ±10V)
4 counters shared with digital inputs.
Low speed counters
do not function in sleep mode.
Size: 32 bit
Max Count rate: 10 Hz
4 high speed inputs
Size: 32 bit
Max Count rate: 10
kHz
2 programmable inputs as either
logic level inputs or
sensitive inputs (10mV) for magnetic pick-ups (max ±10V)
(Serial Data Interface at 1200 bps)
up to 10 SDI-12 sensors
10baseT Ethernet port and a
PC card port are provided
for dataTaker programming and data retrieval.
Flow Control: Hardware
(RTS/CTS),
Software (XON/XOFF), None
Handshake
lines: DCD, DSR, DTR, RTS, CTS
Modem support: auto-answer
and dial out
Protocols: ASCII Command, TCP/IP (PPP), Modbus,
Serial Sensor
Flexible options to allow data to be logged from a wide
range of smart sensors and data streams. Available ports:
Serial Sensor Port
(RS232, RS422, RS485) or
Host RS232 Port*
Baud rate: 300 to 115,200 *If
used as a Serial Sensor channel then the Host Port is not available for other
communications.
Flexible options to allow data to be logged from a wide range
of smart sensors and data streams.
Available ports: Host RS232 Port*
Baud
rate: 300 to 115,200
*If used as a Serial Sensor channel then the Host Port
is
not available for other communications
Protocol:
ASCII command
FTP for automatic data transfer
Modbus for SCADA connection
Access current data and status from any web
browser.
Custom HTML pages can be defined.
Download data in CSV format.
Command interface window.
Define mimic displays.
FTP Client
Automatically
upload logged data direct to an FTP server.
Modbus Server (Slave)
Access
current data and status from any Modbus client
(e.g. SCADA system)
Display Functions: channel data, alarms, system
status.
Keypad: 6 keys for scrolling and function execution.
Status LEDs:
4 for sample, disk, attention and power.
(15-bit gives 1µV)
Types:
B, C, D, E, G, J, K, N, R, S, T
Calibration standard: ITS-90
YSI 400xx Series
Other thermistor types
are supported by thermistor scaling and calculated channels.
**Resistance range can a parallel resistor.
2
of which have 10mV sensitive inputs for magnetic pick-ups
1 latching relay
1 latching relay
4 with logic
output
1 with logic output
4 with logic
output
contacts (max: 30Vdc, 1A)
high speed or phase encoders
Size: 32 bit (>4,000,000,000 counts)
(max ±30V),
2 sensitive inputs (10mV) for magnetic
pick-ups
(max ±10V)
(max ±30V),
2 sensitive inputs (10mV) for magnetic
pick-ups
(max ±10V)
(max ±30V),
2 sensitive inputs (10mV) for magnetic
pick-ups