Jump down to
DaqLink with 4 channels
DAQPro Data
Logger - 8 channelAn eight-channel portable data acquisition
and logging rhs
system with graphic displays and built-in
analysis functions.
Low Cost, Low Power, Portable Data Logger
8 High Resolution Channels (16 bit)
Measures Voltage, Current, Temperature and more
Graphical Display with built in analysis functions
Display Real Time or Logged measurements
(Real Time display for sampling
rates 1Hz or slower)
Setup via Keypad or PC
Samples up to 4,000 samples per second when using 1 channel
Large data storage (512,000 samples)
Rechargeable battery
Built in help and user notes
Download brochure (includes specs) (.pdf file, opens new window) Larger picture of DaqPro & Software
FAQ on Fourier products (Fourier site)
Online Connectivity Enables
Virtual Data Logging
DAQPRO is battery operated and is capable
of sampling, processing and displaying measurements without connecting to a computer.
Designed to serve the needs of professional data loggers, DAQPRO is a professional,
cost-effective, compact and stand-alone data logging system that can be used with
a wide variety of applications.
This 16-bit, high-resolution, eight-channel
data logger offers graphic displays and analysis functions
for measuring
voltage, current and temperature in realtime.
Fast, High Resolution
Data Logging
With its high resolution and fast Analog to Digital converter
(ADC), DAQPro meets the majority of data logging requirements in most industrial
applications. Its unique ability to display measured values and analyze them in
realtime on a graphical interface minimized the need to download collected data
to a computer for further analysis. (Real Time display for sampling rates 1Hz
or slower)
|
Eight input channels for measuring
Selectable ranges for each input are Applications
|
Accessories Product Features Temperature sensorsEsis supplies custom made temperature sensors for any application, Some of the sensors we can provide include: - Custom size stainless steel probes, optionally drilled for fast response to air temperatures - MIMS (Mineral Insulated Metal Sheath) high temperature thermocouples - Waterproof probes - Autoclave rated thermocouples - PVC, Teflon or Fibreglass insulated cables - Thermowells with mating temperature probes - Pipe clamped sensors |
DAQ-PRO,
Including: DAQ-PRO data logger, software, cable set,
mains adaptor, user manual, carrying case.
$1750+GST 4/11
DAQ-PRO accessories
FO-DT332 Temperature sensor thermistor range-25 to150 °C $95+GST 4/11
FO-11599 Replacement rechargeable battery (GP1600MA 7.2V Batt pack) $110+GST
Spare Parts
DAQ-PROUSB communication cable P/N DT180 $POA+GST
TE-12VDC500/21 220/12VDC 500mV power adapter $26+GST
Download DaqLab software for DaqPro Logger DaqPro now supports the Vista Operating System (Vs. 1.40.01 onwards).
Astronauts'
space suits must protect them against hazardously extreme conditions including
lack of pressure and oxygen, radiation, micrometeoroids and temperature extremes.
In space the difference between sun and shade can be hundreds of degrees. The
DaqPRO has been selected to help space suit developers and researchers at a
leading Asian Space Agency counter the dangers of exposure to extremely high
temperatures.
Two DaqPRO units are being used by the Agency to test the heat flux of astronauts' space suits in the field of aerospace thermal protection testing. Military engineers are using the units in rigorous thermal testing procedures.
These tests include: Heat-resistant protective clothing tests, high temperature gas dynamics tests, propellant and powder performance tests and energy saving, thermal insulation performance tests. The fire science scientists used a selection of heat sensors offered by Fourier.
Available temperature sensors inputs from Fourier for the DaqPRO include the NTC, PT100, Temperature Thermocouple J with a range of -200 to 1200 ºC; Temperature Thermocouple K with a range of -250 to 1,200 ºC and Temperature Thermocouple T with a range of -200 to 400 ºC.
- Each input is differential with 2-wire connection
- Sensors are connected via pluggable screw terminals
- 3-wire PT100 sensors are supported by using 2 input channels per sensor (max. 4 PT100 3-wire sensors in this configuration)
- Battery life is 25 hours between charges, and the battery is rechargeable
with the mains adaptor provided with the logger.
For longer duration applications the logger can be run directly
from the mains adaptor, keeping the battery as a backup power source.
- The logger automatically powers off after 15 minutes of inactivity to save battery life
- Note that Channel 8 can be used as an alarm output, or a pulse/frequency input, or an analog input
- Memory: The logger can store a maximum of 512,000 samples total in its internal memory.
- The total number of samples that can be stored is divided by 1, 2, 4 or 8
according to the number of channels in use, as follows:
1 channel yields 512000 samples of storage; 2 channels yields
256000 samples per channel,
3 or 4 channels yield 128000 samples per channel, 5 to 8 channels
yield 64000 samples per channel.
- The logger can be used whilst connected to a PC to log data directly to the
PC (and show a real time graph) using DaqLab software.
This Continuous Mode operation allows a virtually unlimited
number of samples to be logged continuously to the PCs hard drive.
This mode is only available with sampling rates slower than 1 sample/sec
(temperature sensors) or 100 samples/sec (voltage/current sensors).
- For multi-channel setups, all channels record at the same sampling rate.
- A few limitations apply to the sampling intervals available (note this applies to v3.0h or higher of the DaqPRO):
• Maximum sampling rate with one sensor is 4000/s, when using the Current or Voltage sensors only.
• Maximum sampling rate when using any of the temperature sensors is 1/s.
For instance, when using thermocouples, internal temp. sensors, and so on.• Maximum sampling rate with two or more sensors of any type is 1/s.
• DaqPRO displays readings in real-time at rates up to 1/s (Continuous mode)
• DaqLab displays online readings at rates up to 100/s, depending on the sensors connected.
If temperature sensors are being used, then the maximum rate is 1/sec.
- The DaqPro offers several advanced logging features including:
• Alarm levels can be set on each channel, with optional open collector alarm output via channel 8;
• Triggered start the logger will start recording when a measurement passes an upper or lower threshold;
• Event recording the logger will record the exact time whenever an input crosses a threshold
• Time delayed start the logger will start recording after a pre-determined time interval.
• Real-world unit conversion the logger converts voltage or current signals into real-world units, using a linear mapping, and will display the units on its screen and in the DaqLab software.
• Averaging the logger records the average of the last N measurements at each sampling time.
This is useful for smoothing out random noise or eliminating mains interference.• External temperature compensation for thermocouple measurements, an external temperature reference sensor can be attached to input 1 and used instead of the internal CJC (Cold Junction Compensation) sensor.
- The logger can be re-calibrated via a simple procedure using DaqLab software
- The easy to use DaqLab software offers advanced analysis functions on the recorded data, including:
• Curve fitting
• FFT (Fourier transforms)
• Upper and lower envelope calculation
• Averaging / smoothing
• Integral
• Add / subtract channels
• Many other mathematical functions can be
applied to the recorded data
- DaqLab allows data to be easily exported or imported to/from Excel
The user manual can be downloaded from http://www.fouriersystems.com/files/download_center/daqpro_daqlab_userguide.pdf
External Inputs: 0-1 V, 4-20 mA, Thermocouple (J, K, T), PT-100 (2-wire), Pulse counter, Frequency, Contact
12 V power excitation;
Includes AC power adapter $650+GST 7/10
Order SOFTWARE (DL-PCSUITE) separately & calibration certificate.
External Inputs: 0-1 V, 4-20 mA, Thermocouple (J, K, T), PT-100 (2-wire), Pulse counter, Frequency, Contact; 12 V power excitation;
Includes AC power adapter $770.00+GST
Order SOFTWARE (DL-PCSUITE) seperatly & calibration certificate.
WB-PT100-TFLN/03 PT100 temperature sensor (including low temp).
Cable: Dia: 3mm; Length: 3m; Material: Teflon 3 core. Sensor Material: SS 316;
Length: 120mm; Dia: 4.5mm $112+GST
WB-PT100-TFLN/XX For other PT100 cable length please add the additional length required in meters instead of XX in the part number (add this price per meter to the cost of the WB-PT100-TFL/03 listed above) $17.00 (per meter)
WB-PT100-MI3TFLN/06 PT100 for prolonged use at -185 Deg. C a ' Minerally Insulated' type would be recommended.
This type of probe would not be rendered so sensitive and susceptible to failure.
This probe is available in a 3mm diameter with 120mm long stainless steel stem and 6m teflon lead is: 3mm dia $440.00
WB-PT100-MI6TFLN/06 "PT100 for prolonged use at -185 Deg. C a 'Minerally Insulated' type would be recommended.
This type of probe would not be rendered so sensitive and susceptible to failure. $350+GST
This probe is available in a 6mm diameter with 120mm long Stainless Steel stem and 6 Mtr. Teflon lead is: 3mm diameter"
GL-DN-EZ10-KIT GL-DNEZ10 GSM modem kit
with power cable, antenna and USB to Serial adaptor (with power supply) $480+GST 7/10
GL-DN-EZ863-KIT GL-DNEZ863 GSM/GPRS modem kit
with power cable, rechargeable battery, antenna and USB to Serial adaptor (with power supply) $515+GST
GSM modems
GSM modem accessories and parts
GL-DN-EZPCBL Power Cable for EZ modems (supplied w/o power adaptor) $30
GL-DN-YT613938 GL-DNEZ863 Rechargeable Battery $45
GL-DN-US232R-100 USB to Serial adaptor cable $75
GL-DN-GSM-JC000 (RA) Dual Band GSM antenna (right angle) $25
GL-DN-GSM-JC001 Dual Band GSM antenna with 1.2m cable $25
Waterproof Enclosures for DaqLink (Minimum order 5 cases) NE-PCT-1515 150 x 150 x 90 mm Clear Cover $55+GST
DS-1520-PL Internal Plate ( Plastic) for NE-PCT-1515 $8.00
NE-AT-1722 170 x 220 x 110 mm Clear Cover $65.00
DS-1520-PL Internal Plate ( Plastic) for NE-A-1722 $8.00
DL-PCSUITE PC SUITE including softeare CD; USB cable and user manual $155.00
FO-DN-11304 DataNet Internal battery pack, 4.8 V 800 mAh NiMH, (2 batteries in series) $75.00
TE-12VDC500/21 220/12VDC 500mV adapter for DataNet $26.00