This page:
ACR
SmartButton (1 channel, Temperature)
TRH-1000 Temperature & Humidity Logger
Owl Loggers (1
channel, 8-bit - Temp., DC Current, DC Voltage, AC current)
SmartReader Loggers (8-bit) (Multichannel,
various inputs)
SmartReader Plus Loggers
(12-bit) (Multichannel,
various inputs)
Selection
Chart:
Temperature
- various These links jump
to items on this page
Electrical:
AC Current & Voltage
Electrical:
Power Quality
Electrical:
Pulse & Switch Contact & Int Temp
DC
Voltage Current, Pressure,
Carbon
Dioxide & Other Gases, Light Intensity with Temp. & Humidity
Software for ACR Loggers TrendReader Software
Nautilus
rugged & hi temp. loggers - Autoclave Logger
PowerWatch Voltage disturbance recorder Download
Demos - Software Updates - Utilities
ACR Systems Data Loggers are available to support the a wide variety of measurements.
Data LoggerThe
blue or purple links below jump down to info &
prices on this page. |
No.
|
Measurement Range Temperature: Thermistor |
Sampling interval |
Resol-
|
Max. no. of Readings
|
1 |
-40 to 85 ºC Temperature sensor built in |
8s to 34m |
8 |
32,767 |
|
1 |
-40 to 85 ºC (-40 to 185 ºF) |
8s to 34m |
8 |
32,767 |
|
1 |
-40 to 70 ºC (-40 to 158 ºF) |
5s to 12h |
8 |
32,767 |
|
1 |
-40 to 70 ºC (-40 to 158 ºF) |
5s to 12h |
8 |
32,767 |
|
1 |
-10 to 85 ºC (14 to 185 ºF) |
1m to 255m |
8 |
2,048 |
|
2 |
-60 to 255 ºC (-76 to 491 ºF) |
8s to 5d |
8 |
32,767 |
|
8 |
-60 to 255 ºC (-76 to 491 ºF) |
8s to 5d |
8 |
32,767 |
|
2 |
-60 to 255 ºC (-76 to 491 ºF) |
.04s to 8h |
12 |
1,048,000 |
|
8 |
-60 to 255 ºC (-76 to 491 ºF) |
.04s to 8h |
12 |
1,048,000 |
|
3 |
J, K, S, T thermocouple ranges,
Narrow & Wide ranges |
Sampling Interval |
Resolution |
Max. Rdgs. |
|
7 |
J, K, S, T thermocouple ranges, Narrow & Wide ranges |
8s to 5d |
8 |
32,767 |
|
3 |
E, J, K, S, T thermocouple ranges |
.04s to 8h |
12 |
87,000 |
|
8 |
E, J, K, S, T thermocouple ranges |
.04s to 8h |
12 |
1,048,000 |
|
4 |
-230 to 300 ºC , res 0.14°C |
.04s to 8h |
12 |
87,000 |
|
Nautilus85 Al or S Steel |
1 |
For hostile or "wet" environments |
Sampling Interval |
Resolution |
Max. Rdgs. |
Nautilus135 Al or S Steel |
1 |
The high temperature capabilities of the Nautilus135
make it the ideal logger for monitoring temperature in extreme environments or
environments where conventional data loggers are not able to survive. Autoclave
verification; ETO sterilization; kiln drying studies; medical & pharmaceutical
studies; agricultural, ocean and pond studies; environmental studies; process
monitoring; HVAC; hostile environmental monitoring |
8s to 34m |
8 |
244,800 |
4 |
-40 to 70 ºC (-40 to 158 ºF), 0 to 95% RH |
8s to 5d |
8 |
32,767 |
|
4 |
-40 to 70 ºC (-40 to 158 ºF), 0 to 95% RH |
.04s to 8h |
12 |
87,000 |
|
2 |
-40 to 70 ºC (-40 to 158 ºF) & 0 to 100% RH |
8s to 34m |
8 |
65,000 |
|
Data LoggerThe
blue or purple links below jump down to info &
prices on this page. |
No.
|
Measurement Range Electrical: AC Current & Voltage |
Sampling interval |
Resol-
|
Max. no. of Readings
|
1 |
5, 25, 100, 250A (with OWL-A65FL
50Hz current probe) |
0.2s to 12h |
8 |
32,767 |
|
4 |
50 or 60 Hz, 5 to 500 A (3000 A CT also available) |
8s to 5d |
8 |
32,767 |
|
8 |
5 to 500 A (3000 A CT also available), 120 Vac or 480 Vac. Can be used with ACR AC voltage transducers to monitor 3 phase. |
.04s to 8h |
12 |
1,048,000 |
|
PowerWatch
220/240V |
1 |
Monitor and record essential voltage disturbance information from any 220/240
volt Australian, European or UK power receptacle. Single phase,
Hot to Neutral or Neutral to Ground. Surge, Sag & Outage, Impulse, Frequency,
Time. Set up your pre-determined disturbance threshold values or use the industry
standard default values, and plug it in. |
|
N/A |
Max. Rdgs. |
1 |
Monitor and record voltage disturbance info from any North American
power receptacle. |
|
N/A |
4,000 |
|
3 |
Counting and recording digital pulses or switch contact closures.
It has two input channels, each with three selectable frequency ranges. |
Sampling
Interval |
Resolution |
Max. Rdgs. |
|
2 |
4095 pulse/sample period max. Max Freq: 100 KHz, no Temp. |
.04s to 8h |
12 |
87,000 |
|
Data LoggerThe
blue or purple links below jump down to info &
prices on this page. |
No.
|
Measurement Range Pressure |
Sampling interval |
Resol-
|
Max. no. of Readings
|
5 |
0 to 5, 30, 100, 150 psi |
8s to 5d |
8 |
32,767 |
|
4 |
0 to 5, 30, 100, 150 psi, & 10" WC |
.04s to 8h |
12 |
87,000 |
|
2 |
±0.5, 1, 2, 5, 10" WC |
.04s to 8h |
12 |
21,500 |
|
In the left column, the blue or purple links jump down to info & prices on this page, and the red links below jump to data on the ACR site (opening in a new window). |
The
heading links in this column go to data on the ACR website |
||||
| Process Signal DC Voltage, Current |
|||||
1 |
0 – 38.4 Vdc max. (32 software selectable ranges available) |
Sampling Interval |
Resolution |
Max. Rdgs. |
|
1 |
0 – 24 mA DC, 4-20mA, Sensing resistor: 100 ohms |
0.2s to 12h |
8 |
32,767 |
|
8 |
2.5v, 5v, 10v, 25mA, 200mV |
8s to 5d |
8 |
32,767 |
|
8 |
2.5v, 5v, 10v, 25mA, 200mV |
.04s to 8h |
12 |
1,048,000 |
|
ACR-205 |
5 |
Indoor air quality by measuring and recording temperature, relative humidity,
carbon dioxide, and one or two other gases at the same time. These other gases
can include: CO, NO2, O2, NH3, Cl2, ClO2, F2, H, HCl, HCN, H2S, NO, O3, or SO2. |
Sampling
Interval |
Resolution |
Max. Rdgs. |
IAQ
Logger |
5 |
The IAQ Logger, when combined with the Telaire 7001 Handheld CO2 Monitor, records
the three leading indicators of indoor air quality: (1) temp., (2) relative humidity,
and (3) carbon dioxide. |
8s to 5d |
8 |
32,767 |
Conservation
Logger |
4 |
Temp. and relative humidity logger with two external channels for use
with a variety of sensors. It is equipped with an LED light that will alert the
user if measurements fall above or below user set limits. |
|
12 |
32,767 |
Time
stamping of Readings in ACR Data Loggers
All ACR loggers have an accurate clock, but not a real time clock. Data is time
referenced when the data is downloaded, from the time and date of the computer.
The PC being used should have it's clock set accurately (automatic via internet
with Windows XP).
Time references can be adjusted with the TrendReader software.
Data collected in ACR Data Loggers is downloaded using the USB or serial RS232 port of a computer.
ACR Systems data loggers are used in a wide variety of industries.
Here are just some of the product applications where ACR Systems data loggers
provide invaluable measurement solutions.
Software
for ACR Loggers (link to ACR site, opens in new tab) covers the following:
TrendReader
2 Graphing & Analysis
- for ACR's SmartReader
Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers
SmartReader
Data and Download trial
TrendReader Express - for JR-1000/1001,
Nautilus85/135, and TRH-1000 data loggers
PowerWatch Software
- for ACR's PowerWatch voltage disturbance recorder
SmartButton
Reader - for SmartButton data loggers
TalkBack Software -
for SmartReader Plus Data Loggers
RealTime Graphing Sw - for
SmartReader, SmartReader Plus and PowerWatch
Solution Developer's Kit - Software
Code for SmartReader Plus, JR, TRH-1000 and Nautilus data loggers
Data
on all ACR Systems Loggers:
JR Series: Low-cost temperature data logger
OWL Series: Singl e-channel configurable 8-bit
data loggers
SmartReader: Multi-channel configurable 8-bit data
loggers
SmartReader Plus: Multi-channel configurable 12-bit
data loggers
Nautilus: Single-channel waterproof temperature
data loggers
SmartButton: Button-sized temperature data logger
PowerWatch: Voltage disturbance recorder
TRH Series: Low-cost temperature and relative humidity data loggers
Other Loggers: Miscellaneous and specialty loggers
JR-1000 Data Logger Series - Easy to use, low cost data loggerTemperature
sensor built in. (Supercedes the ACR JR Data Logger) zwh
All JR-1000 loggers are now shipped with TrendReader Express software,
which allows many more features & functions
than those of the original ACR-JR logger.
It can plug directly into a DB9
COM port connector on a computer.
Size: 33 x 43 x 20 mm,
Weight: 35 grams, Case Material: Polyurethane
Mounting: Magnetic
backing
Operating Range: -40 C to 85°C, Clock
Accuracy: +/-2 seconds per day
Battery: 3.6 volt lithium, 0.47 amp-hour,
Battery Life: Five year warranty (under normal use).
Memory Size: 32 K (32,000
readings up to 244,800 readings when data compression is selected)
Resolution:
8 Bit (1 part in 256)
Sampling Methods: First in first out, stop when full,
delay start, data compression, spot & average sampling
Sampling Interval:
8 seconds to 34 minutes
PC Requirements: IBM PC, any Windows, with a least
2 MB RAM, 10 MB of hard drive disk space and
one free serial port. An RS232
to USB Converter (USB-100 $68+GST) may be used for USB connection to the computer.
Includes TrendReader Express software.
The JR-1000 can plug directly
into a DB9 COM port connector on a computer. RS232 cable is not included.
USB: Can be used in co-ordination with a USB-100 USB to Serial
converter cable ($68+GST)
Dim: 34mm x (21mm incl magnetic strip), length:
38mm not incl. the DB9F. JR-1000 Data Logger: $255+GST
Optional serial cable: $10+GST when ordered with the logger
ACR News about JR-1000 Datasheet for JR-1000 Manual for Trendreader Express (.pdf 948KB)
TrendReader Express (a
cut down version of TrendReader)
TrendReader
Express Data TrendReader
Data and Download trial
Use
this intrinsically safe logger in hazardous applications in which there are flammable
gases or explosives.
Range: -40 to 85 °C, Accuracy: ±0.2
@ 25 ° C Data:click
here Sampling Interval adjustable 8 seconds to 34 minutes.
UL Intrinsically Safe for use in:
Class 1, Division 1, Groups A, B, C, D
Class 2, Division 1, Groups E, F, G
Class 3, Division 1, Hazardous Locations
T3C
JR - 1001 Intrinsically Safe- Temperature
logger for hazardous applications $453+GST
Temperature Range-40 °C to 70 °C Data
sheet (.pdf file)
Temperature Accuracy: +/-0.6 °C @25 °C,
+/-2°C from -40 °C to 70 °C
RH Range: 0-100%,
RH Accuracy: +/-4% between 20% to 80% RH, otherwise +/-5%
Calibration:
Factory calibration verification and NIST certificates are available upon special
request
Battery: 3.6 volt lithium, 1 amp-hour, Battery Life: Five year warranty
(under normal use).
Memory: 64KB (32,000 data points per channel) 8 Bit (1
part in 256)
First in first out or stop when full, delay start
Sampling
interval: 8 seconds to 34 minutes
TrendReader Express software (included).
Windows 3.1, 95, 98, Me, 2000, XP or NT, one free serial port.
The TRH-1000
can plug directly into a DB9 COM port connector on a computer. RS232 cable
is not included.
USB: Can be used in co-ordination with a USB-100 USB
to Serial converter cable ($68+GST)
25.4 x 58.4 x 81.3 mm, 74 grams,
Cycoloy® (GE Plastics) C120 ABS + Polycarbonate, Magnetic backing
TRH-1000
Temperature & Humidity Logger $621+GST

1 channel, 8-bit loggers - Temperature, DC Current, DC Voltage, AC current
The OWL series of data loggers are Single-Channel, configurable
8-bit data loggers featuring
10-year battery life, memory capacity of 32,767
readings, optical data transfer, and
flashing visual alarm. zwh
Common Specs:
Size 60 mm x 48 mm x 19 mm, Non-watertight model; 54g, Watertight model (OWL 100);
80g,
-40°C to 70°C, 32,767 readings, User selectable sampling rates from
5 per second to once every 12 hours,
32K readings, 8-bit (1 part in 256),
Can be optimized to the equivalent of 10 bit resolution,
Red LED alarm, Removable
snap type connector,
Data
and common specs on OWL loggers: click here FAQ
on OWL Loggers
Also required: Software,
& Light Wand for communications:
TrendReader®
(for Windows® 3.1, '95, '98, Me, 2000, NT and XP): $332+GST
Uses
light wand for communications with logger (uses visible red light).
An
RS232 to USB Converter (USB-100 $68+GST) may be used for USB connection to the
computer.
Data
on Trendreader Software: see below
Note: The Trendreader Software
is the same for Owl, SmartReader and SmartReaderPlus loggers,
however the included
hardware manual & communications are specific to the logger.
OWL
100 One internal temperature channel,
32KB readings,
Accuracy +/-0.5°C @ 25° C, Can be increased by using narrow
range feature
Standard Resolution 0.5°C at 25° C, better than 1°C between - 25° and 70°C,
Better than 2.0° C between-40°C and -25°C. Can be increased by using narrow range feature
OWL-100WP Poly: Submergence Rating 100m in fresh water .
OWL-100SC Plastic is not submersible Data FAQ
OWL-100WP single channel waterproof temperature logger
$548+GST 4/06
OWL-100SC
single channel temperature logger $ 457+GST
OWL
200 Records temperature, resistance or switch status in tight environments where typical data loggers cannot fit.
The OWL's external
temperature sensor (thermistor) allows measurements in excessive heat or extremely
tight environments.
32 KB readings, One channel: external temperature, resistance
or switch status.
Logger Accuracy +/-1% of range Data FAQ
External Temperature sensor must be ordered separately.
OWL-200SC single channel exertnal temperature logger $457+GST
ET
Series Thermistor Probes 25 x 5mm probe with rounded tip (except -GP, -STP,
-SMP), teflon cable, all are waterproof
ET-016 35-0001
General Purpose: -67.5 to 228°C, best accuracy: -35 to 95°C
ET-004-GP 35-0028 Low Temperature:
best accuracy: -60 to 55°C
ET-004 35-0000
Low Temp Penetration:
best accuracy: -60 to 55°C
ET-081 35-0002
High Temperature: glass bead thermistor 10
to 170°C /6m: $118+GST
ET-086 35-0003
Oven Temperature:
best accuracy: 70 to 255°C /45cm cable: $95+GST /6m:
$125+GST
ET-016-STP 35-0020 Skin Surface Temperature: -67.5
to 228°C, best accuracy: 20 to 40°C
(68 to 104°F) /6m $118+GST
ET-016-SMP 35-0025 Pipe
Surface Temperature: -67.5 to 228°C, best accuracy: -35 to 95°C
(-30 to 200°F) /6m $118+GST
P1713 Plastic sensor
cover, 2m Plastic cable 0 to 105°C (uses same sensor as ET-016
above) $41+GST h
P1723 Stainless Steel tip, 2m Plastic cable
0 to 105°C (uses same sensor as ET-016 above) $64+GST h
ET-086 Oven temperature probe 70° to 255°C: with 45cm cable: $95+GST with 6m cable: $125+GST
Also required: Software & Light Wand for communications: see below
OWL
300 Records AC current in applications where
typical recorders cannot fit.
Due to its small size, the OWL model 300 can
go directly into an electrical panel or even inside small electrical equipment
allowing the user to record electric current in a safe, discrete and convenient
manner. OWL
300 Data FAQ
OWL-300SC single channel AC current logger $
457+GST
OWL 400 Records DC voltage with ease and convenience.
Ideal for monitoring (through commercially available
transducers) a wide variety of measurement parameters.
All voltage signals can
be converted into custom engineering units using TrendReader's® simple equation
editor.
OWL
400 Data FAQ
Input Range: 32 software selectable ranges available from 0-121 mV
to 0-39 V. 0 to 38.4 Volts DC maximum
OWL-400SC
single channel dc voltage logger $457+GST
OWL
500 Records DC current with ease and convenience.
Ideal for monitoring (through commercially available transducers) a wide variety
of measurement parameters.
All current process signals can be converted into custom
engineering units using TrendReader's® simple equation editor.
OWL
500 Data FAQ
You can connect the output of a 4-20 mA transducer to OWL-500.
You
can also define the unit (for example Gallons, PSI, etc) and write a custom equation
to convert the readings,
and have the graphs showing your preferred units
OWL-500SC single channel DC current logger $457+GST
Also required: Software & Light Wand
for communications:
Software & Light Wand:
TrendReader® (for Windows® 3.1, '95, '98, Me, 2000, NT and XP),
and LIC-101 Light Wand for communications with logger (uses visible red light).
$332+GST
An RS232 to USB Converter (USB-100 $68+GST)
may be used for USB connection to the computer.
Data on Trendreader Software: see below
Note: The Trendreader Software is the same for Owl, SmartReader and SmartReaderPlus
loggers,
however the included hardware manual & communications are specific
to the logger.
Common Specs:
Size 60 mm x 48 mm x 19 mm, Watertight model (OWL 100); 80g, Non-watertight
model; 54g
-40°C to 70°C, 32,767 readings, User selectable sampling rates
from 5 per second to once every 12 hours,
32K readings, 8-bit (1 part in
256), Can be optimized to the equivalent of 10 bit resolution,
Red LED alarm,
Removable snap type connector,
Cable: LIC-101 RS232
serial optical interface cable is required.
Time
stamping of Readings in ACR Data Loggers
All ACR loggers have an accurate clock, but not a real time clock.
Data is time
referenced when the data is downloaded, from the time and date of the computer.
The PC being used should have it's clock set accurately (automatic via internet
with Windows XP).
Time references can be adjusted with the TrendReader software.
Note: some of these are being phased out. Use SmartReader
Plus loggers below.
8-bit loggers (1 part in 256), 32K readings, -40°C to 70°C, zwh
TR-WIN-SR Software for Smartreader $335+GST ($368.50incGST)
Common to all models of SmartReader SR
Internal Temperature Sensor Specs (.
Type: Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25ºC.
Tolerance (sensor only): +/-0.2ºC, over the range of 0 to 70ºC.
Range: -40 to 70ºC.
Resolution: 0.4ºC @ 25ºC. Better than 1ºC between -25ºC and 70ºC .
Better than 2.0ºC between -40ºC and -25ºC.
Memory: 32K (32,768 readings), Stop when full or overwrite.
Battery 3.6V Lithium, 1AH, 10 year life, factory replaceable.
User selectable sampling rates between 8 seconds to once every 5 days,
Dim: 107 mm x 74 mm x 22 mm, 110gm
Choose either IC-101 RS232 serial interface cable, or
IC-102 USB interface cable
SmartReader 1: Temperature, Two channels
(one for
the internal temperature sensor and one for remote sensing of temperature, resistance,
or switch status)
SmartReader
1 Data
SmartReader 2: Temperature & Relative Humidity,
Four
channels (one for the internal temperature sensor, one for the
internal RH sensor,
one for optional external RH and one for optional external
temperature or resistance)
SmartReader
2 Data
RH Sensor: Range: 0 to 95% (non-condensing)
Accuracy: +/-
4% RH from 10 to 90% (-20 to 40°C [-4 to 104°F])
Resolution: Better
than 0.4% between 25 & 60% RH at 25° C (77° F) SmartReader
2: $995+GST 4/06
EH-020A External Humidity & Temperature probe for tight or remote locations (up to 30m)
10 to 90% RH, -20 to+40°C for SmartReaders SR2, SR4, SRP2, SRP4 (not SRP4 LPD) $425+GST
SmartReader 3: AC Current Accessories: ACR AC Current Probes SmartReader
3 Data FAQs $888+GST
More
information on SR3 & SRP3
Current Clamps: (Only the current probes from ACR are compatible with SR3 or SRP3 loggers.)
A75CE (50Hz) 10A, 50A, 250A, 500A with 120% overrange capability Large Picture $236+GST
A65CE (50Hz) 5A, 25A, 100A, 250A with 120% overrange capability $223+GST
CT-50-2L: up to 3000 Amps, this is clamped over the A60FL or A70FL clampsSee also: 3 Phase Power Analyzer: Lutron DW-6092 logs to an SD flash card. With Current clamps 20/200/1200 amps.
(this site, opens new tab or window)
SmartReader 4: Absolute, Gauge Pressure Five channels
(one for ambient temperature, one for optional Pressure Module, one for optional on-board RH sensor, one for
optional remote thermistor and one for optional remote Relative Humidity probe).
Accessories: ACR Pressure Modules. ACR RH-002 RH Sensor. ACR EH- 020A RH/Temp.
Probe.
ACR ET Series Temp. Probes. Any NTC Temp. Probe SmartReader
4 Data
SmartReader 5: J, K, S or T type Thermocouple, Two channels
(one internal thermistor for cold-junction compensation and two external; one for narrow range thermocouple
applications, the other for a wider range), Acc +/- 1% span + resolution, 32K
readings
SmartReader
5 Data $915+GST SRP 5 (see
below) is recommended as probably more suitable than this item.
SmartReader 6: J, K, S or T type Thermocouple,
Six channels
(one internal thermistor for cold-junction compensation
and six external thermocouple channels. Specify narrow or wide temperature range
when ordering), Acc +/- 1% span + resolution, 32K readings
SmartReader
6 Data $1045+GST 3/06 SRP
6 (see below) is recommended as probably more suitable than this item.
SmartReader 7: DC Voltage, DC Current, seven input channels 0 to 2.5 volts DC. 0 to 5.0 volts DC (two channels). 0 to 10.0 volts DC.
0 to 200 millivolts DC.
0 to 25 milliamps DC (two channels)
Optional Input Ranges: All
external channels 0 to 2.5 volts, 0 to 5 volts, 0 to 10 volts, or 0 to 25mA. Accuracy:
+/-1% full scale
SmartReader
7 Data
SmartReader 8: up to eight different temperature locations simultaneously using optional probes (NTC thermistor).
SmartReader 8 Data
Temperature Sensors - High Precision NTC Thermistors
The link above is direct to the manufacturer Tewa in Poland.
Please request quote from Esis
Disk - Pearl glass - chip - custom - Microchip probes - sealed in glass
SmartReader 9: Pulse Data Logger two channels, 8-bit counting
and recording of switch contact closures and voltage pulses.
It has two input channels each with three selectable frequency ranges. SmartReader
9 Data
See
below the list of loggers with various input types. zwh
SmartReader Plus loggers have USB or serial port interface to computer, for
setting up and unloading data.
Size: 107 x 74 x 22 mm Weight:
110 grams
Operating Limits: -40°C to 70°C and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day. See note in green
below.
Battery: 3.6 volt Lithium, 1 Amp-Hour Power Consumption: 5 to
10 microamps (continuous)
Battery Life: 10-years warrantied (under normal
use). Factory replaceable
Memory Sizes: 32 K (21,500 readings). 128
K (87,000 readings). 1.5 MB (1,000,000 readings).
See specific models for availability. It is not economical to upgrade
from the memory size.
Sampling:
Fast Mode: 25
per second, to every 2 minutes in .1 sec incr.;
Normal
Mode: every 8 seconds, to every 8 hours
Delayed start
mode.
The SmartReader Plus always samples internally every
8 seconds (or less for faster sampling rates).
When using slower sampling
rates, the 8 second internal samples are averaged over the sample period, and
logged to memory at the set sampling rate.
This is an advantage in many applications.
Faster
logging, up to 25 samples per second
To log at rates faster than once every
8 seconds, SmartReader Plus Data Loggers require a separate 5V power supply.
This
can be achieved by using a USB cable to a computer (powered up), or the BP-101
Battery pack, or a 5V power supply.
For fast scanning, see BP-101 Battery Pack option at the end of this
section.
BP-101 Battery pack: A male stereo jack and cable plugs
directly into the communication port on the logger.
Uses 4 AAA batteries (included)
and are user replaceable. Length: 23cm.
Specifications common to all SmartReader Plus loggers FAQs (links to ACR website)
Time
stamping of Readings in ACR Data Loggers
All ACR loggers have an accurate clock, but not a real time clock.
Data is time
referenced when the data is downloaded, from the time and date of the computer.
The PC being used should have it's clock set accurately (automatic via internet
with Windows XP).
Time references can be adjusted with the TrendReader software.
Internal
Temperature Sensor Specs
(common
to all models of SmartReader Plus SRP, except SRP9)
Type:
Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25ºC.
Tolerance
(sensor only): +/-0.2ºC, over the range of 0 to 70ºC .
Range: -40
to 70ºC.
Resolution: 0.03ºC at 25ºC . Better than 0.07ºC
between -25ºC and 70ºC.
Better than 0.13ºC between -40ºC
and -25ºC.
Also required with SmartReader
Plus loggers:
Software: TrendReader for Windows, data see below
Choose either IC-101 RS232 serial interface cable,
or
IC-102 USB interface cable
An RS232 to USB Converter (USB-100 $68+GST) may
be used with the Serial cable.
EH-020A External Humidity & Temperature probe for tight or remote locations
(up to 30m)
10 to 90% RH, -20 to+40°C, for SmartReaders
SR2, SR4, SRP2, SRP4 (not SRP4 LPD) $425+GST
Two channels:
one for internal temperature sensor
and
one for remote sensing of temperature,
switch status or resistance
Accessories:
ACR ET Series Temperature Probes or any NTC thermistor probes
See
also SRP8 Eight Channel Temperature Logger below
SmartReader Plus 1, SRP1 Data SRP1 32K: $653+GST SRP1 128K: $849+GST
See list of Thermistor probes under SRP8 below
See below, after SRP8.
SmartReader Plus 2 is a 4channel self-contained data logger that
is able to record both temperature and relative humidity.
The on-board RH
sensor is temperature compensated, permitting reliable, worry-free RH readings.
For remote sensing, simply attach an external temperature or temperature/RH
probe. Type: Capacitive thin polymer film.
Four Channels: one
for ambient temperature, one for relative humidity [internal sensor],
one for remote relative humidity [external sensor], and one for remote temperature,
resistance, or switch status.
RH Sensor: Range: 0 to 95% RH (non-condensing)
Accuracy: +/- 3% RH from 10 to 90% RH (-20 to 40ºC )
Resolution: Better
than 0.04% RH between 25 and 60% RH at 25ºC
If using the external channel
for contact closure, Equation 44 in the TrendReader software is used, to produce
an off/on trend plot.
SmartReader
Plus 2, SRP2 Data
SmartReader Plus 2 (SRP2): $1173+GST 4/06
Also required with SmartReader Plus loggers: Software: TrendReader for Windows, data see below
Choose either IC-101 RS232 serial interface cable,
or
IC-102 USB interface cable
An RS232 to USB Converter (USB-100 $68+GST) may
be used with the Serial cable.
SmartReader Plus 3 easily and accurately records AC current and voltage.
The easy-to-use ACR CT's (current transformers) provide safe current readings
by simply clamping them around the power leads.
AC voltage is monitored by
connecting ACR's AC voltage transducer to the 5V channels.
Current Ranges: With A60CE (60 Hz) and A65CE (50 Hz): 5, 25, 100 and 250 Amps.
With A70CE (60 Hz) and A75CE (50 Hz) current probes: 10,
50, 250 and 500 Amps.
with the ACR CT-50-2L: up to 3000 Amps
Nominal Voltage Ranges: 120 V (1 phase, 60 Hz). 480 V (3
phase, 60 Hz)
No.
of Channels: Eight. (One internal for ambient temperature, four for AC current
for use with ACR probes
and three with 0-5 VDC inputs,
which can be used with ACR AC voltage transducers to monitor 3 phase voltage
SmartReader
Plus 3, SRP3 Data (opens new window)
Current Clamps: (Only these Amprobe current clamps are compatible with SR3 or SRP3
loggers.)
A75CE (50Hz) 10A, 50A, 250A, 500A with 120% overrange capability
Large Picture $236+GST
A65CE (50Hz) 5A, 25A, 100A, 250A with 120% overrange capability $223+GST
These clamps have a DC output of approx. 260uA into a 400 Ohm load at full scale.
CT-50-2L: up to 3000 Amps, clamped over the A60FL
or A70FL clamps - DISCONTINUED - no replacement model available as yet
SRP3
32K, SmartReader Plus 3 AC Current and Voltage: $1,072+GST 11/06
SRP3 128K, SmartReader Plus 3 AC Current
and Voltage: $1,268+GST
SRP3 1.5M, SmartReader
Plus 3 AC Current and Voltage: $2,756+GST
Faster logging, up to 25
samples per second
To log at rates faster than once every 8 seconds, SmartReader
Plus Data Loggers require a separate 5V power supply.
This can be achieved
by using a USB cable to a computer (powered up), or the BP-101 Battery pack, or
a 5V power supply.
For fast scanning, see BP-101 Battery Pack option at the end of this
section.
BP-101 Battery pack: A male stereo jack and cable plugs directly into the communication port on the logger.
Uses 4 AAA batteries
(included) and are user replaceable. Length: 23cm.
The SmartReader
Plus always samples internally every 8 seconds (or less for faster sampling rates).
When using slower sampling rates, the 8 second internal samples are averaged
over the sample period, and logged to memory at the set sampling rate.
This is
an advantage in many applications.
Also required
with SmartReader Plus loggers:
Software: TrendReader for Windows,data see below
Choose either IC-101 RS232 serial interface cable,
or IC-102 USB interface cable
An RS232 to USB Converter (USB-100 $68+GST) may
be used with the Serial cable.
See also:
3
Phase Power Analyzer: Lutron DW-6092 logs to an SD flash card. With
Current clamps 20/200/1200 amps.
(this
site, opens new tab or window)
See also Dent Instruments (this site, opens new tab or window)
See also Thermal Imaging Camera (this site, opens new tab or window)
SmartReader Plus 4 (SRP4) 4 channel
data logger for pressure
One internal temperature sensor for ambient temperature,
one channel for pressure, and
two channels for the optional remote relative
humidity and temperature probe [model EH-020A])
0 to 5psi 30kPa Gauge,
30 psi 200 kPa Absolute,
30 psi 200 kPa Gauge,
100
psi 700 kPa Absolute, 100 psi 700 kPa Gauge, 150
psi 1000 kPa Gauge,
& 10" WC 2.5kPa Gauge.
Sampling: 0.04s (25 per sec.) to 8h. 12-bit resolution, 87,000
readings
The SmartReader Plus 4 data logger provides easy monitoring and
troubleshooting of pneumatic control systems.
The unit is completely self-contained
with a 1/4" quick-release pressure fitting to allow a fast and trouble-free
connection.
As an added bonus, the SmartReader Plus 4 also monitors temperature
and relative humidity.
Data on SmartReader Plus 4 (ACR website)
Faster logging, up to 25 samples per second
To
log at rates faster than once every 8 seconds, SmartReader Plus Data Loggers require
a separate 5V power supply.
This can be achieved by using a USB cable to a
computer (powered up), or the BP-101 Battery pack, or a 5V power supply.
For
fast scanning, see BP-101 Battery Pack option at the end of this section..
BP-101 Battery pack: A male stereo jack and cable plugs directly into the communication port on the logger.
Uses
4 AAA batteries (included) and are user replaceable. Length: 23cm.
SmartReader
Plus 5 (SRP5) 3 channel data logger
SmartReader
Plus 5, SRP5 Data 32K version: $1189+GST, 128K
version: $1386+GST
SmartReader Plus 6 (SRP6) 8 channel data logger provides
easy and accurate temperature recording
from J, K, S, T, and E type
thermocouples.
7 external inputs and an on-board cold-junction thermistor,
one of the most compact, multi-channel data recorder available.
12 bit resolution
means the entire range of compatible thermocouples can be measured accurately.
Memory options: 32KB, 128KB or 1.5MB. Accuracy: ±0.5% of span
+resolution
J type: -50 to 600°C, Resolution: 0.3°C K
type: -100 to 1150°C, Res: 0.5°C T type: -200
to 400°C, Res: 0.4°C
SmartReader
Plus 6, SRP6 Data
SRP6 32KB: $1294+GST
SRP6 128KB:
$1490+GST
7 external inputs and 1 internal temperature channel
Data on SRP7 (.pdf)
SmartReader
Plus 7, SRP7 Data (page on ACR Canada site)
Standard
Input Ranges for SRP7:
0 to 2.5 VDC, 0 to 5.0
VDC (two channels), 0 to 10.0 VDC, 0 to 25 mA DC (two
channels), 0 to 200 mV DC
SRP-007- 32K, 01-0014: $1359+GST
SRP-007-32K
with all 0-25mA inputs @ $ 1,490+GST
SRP-007-128K std inputs
$ 1,556+GST (delivery 7-10 days)
SRP-007-128K with all 0-25mA inputs @ $ 1,687+GST
SRP-007-1.5M: 01-0152
Optional Input arrangements (factory option): 32K versions: $1490+GST, 128K versions: $1687+GST
a) All external
channels 0-25mA: (32K:
01-0017, 128K: 01-0126, 1.5M: 01-0156)
b) All external
channels 0-2.5 VDC: (32K: 01-0018,
128K: 01-0127)
c) All external channels 0-5 VDC: (32K:
01-0107, 128K: 01-0124, 1.5M: 01-0154)
d) All external
channels 0-10 VDC: (32K:
01-0020, 128K: 01-0125, 1.5M: 01-0155)
Accuracy: +/- 0.5% of full scale
Faster logging, up to 25 samples per second
To
log at rates faster than once every 8 seconds, SmartReader Plus Data Loggers require
a separate 5V power supply.
This can be achieved by using a USB cable to a
computer (powered up), or the BP-101 Battery pack, or a 5V power supply.
For
fast scanning, see BP-101 Battery Pack option at the end of this section..
BP-101 Battery pack: A male stereo
jack and cable plugs directly into the communication port on the logger.
Uses
4 AAA batteries (included) and are user replaceable. Length: 23cm.
8-Channel
Temperature Data Logger
Eight channels: one for the internal temperature
sensor and
seven
for remote sensing of temperature, resistance, or switch status
The SmartReader
8 data logger can measure temperature in eight different locations simultaneously
using ACR's ET series thermistor probes.
Monitor and record high temperature,
low temperature, pipe surface, skin surface, or a variety of other temperatures.
Data on SRP8 (.pdf) SmartReader
Plus 8, SRP8 Data (page on ACR Canada site)
SRP-008 thermistor
8 ch logger, 32K $1,242.00 ea. + GST
SRP-008 thermistor 8 ch
logger, 128K $1,438.00 ea. + GST
ET Series Thermistor Probes 25 x
5mm probe with rounded tip (except -GP, -STP, -SMP), teflon cable, all are waterproof
ET-004-GP 35-0028 Low Temperature:
best accuracy: -60 to 55°C
ET-004 35-0000
Low Temp Penetration:
best accuracy: -60 to 55°C
ET-081 35-0002
High Temperature: glass bead thermistor best accuracy: 10
to 170°C /6m: $118+GST
ET-086 35-0003
Oven Temperature:
best accuracy: 70 to 255°C /45cm cable: $95+GST /6m:
$125+GST
ET-016 35-0001
General Purpose: -67.5
to 228°C, best accuracy: -35 to 95°C
ET-016-STP
35-0020 Skin Surface Temperature: -67.5 to 228°C, best accuracy: 20
to 40°C (68 to 104°F) /6m $118+GST
ET-016-SMP 35-0025
Pipe Surface Temperature: -67.5 to 228°C, best accuracy:
-35 to 95°C (-30 to 200°F) /6m $118+GST
P1713 Plastic
sensor cover, 2m Plastic cable 0 to 105°C (uses same sensor
as ET-016 above) $41+GST h
P1723 Stainless Steel tip, 2m Plastic cable
0 to 105°C (uses same sensor as ET-016 above) $64+GST h
ET-086 Oven temperature probe 70° to 255°C: with 45cm cable: $95+GST with 6m cable: $125+GST
Temperature Sensors - High Precision NTC Thermistors anv
The link above is direct to the manufacturer Tewa in Poland.
Please request quote from Esis
Disk - Pearl glass - chip - custom - Microchip probes - sealed in glass
SmartReader
Plus 10 is a temperature logger with four channels:
an internal thermistor
channel and three external channels specifically designed for use with RTD (Resistance
Temperature Detector)
temperature probes, designed to precisely measure temperature
over a wider temperature range than a thermistor, without sacrificing accuracy
or resolution. Data sheet (.pdf) SmartReader
Plus 10, SRP10 Data (page on ACR Canada site)
Two-, three-, and four-wire RTDs may be used with the SmartReader Plus 10, however, four-wire RTDs produce the highest accuracy. RTDs with a Temperature Coefficient Resistance (TCR) of 0.00385 can be used with this data logger.
SRP-010 128K RTD temp logger $1,373+GST 10/07
Faster logging, up to 25 samples per second
To log at
rates faster than once every 8 seconds, SmartReader Plus Data Loggers require
a separate 5V power supply.
This can be achieved by using a USB cable to a
computer (powered up), or the BP-101 Battery pack, or a 5V power supply.
BP-101
Battery Pack (Catalog No. 01-0078) SmartReader Plus Data
Loggers can log at rates faster than once every 8 seconds when the BP-101 Battery
pack. A male stereo jack and cable plugs directly into the communication port
on the logger.
Uses 4 AAA batteries (included) and are user replaceable. Length:
23cm.
BP-101 Battery pack: $95+GST
TrendReader® 2 is a powerful, versatile and easy-to-use software application designed exclusively for ACR's
SmartReader
Plus,
SmartReader,
IAQ, OWL, TRH, JR and Nautilus data loggers.
Powerful features and easy setup enables collected data
to be thoroughly analyzed in seconds.
Data Sheet on TrendReader 2 (pdf file, opens in new tab)
TrendReader Express software is designed exclusively for the JR-1000/1001, Nautilus 85/135 and TRH-1000 data loggers (see further down).
Software details (ACR site)
Data collected in ACR Data Loggers is downloaded using the USB or serial RS232 port of a computer.
TrendReader Software features:
• Simple logger setup window • Compound multiple
graphs to a resultant graph • Export data to most spreadsheet formats
• Interface with remote loggers via modem
• Multi-graph display
• Zoom • Scale units • Add comments •
Data table view
TrendReader Data and Download trial (ACR site)
Data on earlier version TrendReader Standard Software (.pdf file from Esis site)
Update:
TrendReader update is available free of charge to existing users at the ACR
website
Simply click on the "Download" tab on the opening screen,
and download..
This update software will only install into a PC or laptop
with an existing authorised version of TrendReader for Windows software.
The cable has a 3.5mm jack with ring, tip & sleeve
for the logger, and a USB or DB9F for the computer port.
An adaptor to DB25F
is also provided with the serial RS232 option.
TR-2 TrendReader2 software package incl. IC-101 serial interface cable: $332+GST
TR-2 TrendReader2 software package incl. IC-102 USB interface cable: $332+GST
Be sure to specify either USB or Serial RS232 Cable
TrendReader Express is designed exclusively for the JR-1000/1001, Nautilus 85/135 and TRH-1000 data loggers.
This easy-to-use software incorporates the advantages of simple functionality with advanced features that are normally associated with more expensive data acquisition software.
Support can be obtained from ACR Systems help desk via email, (there is a big time difference between Canada & Australia)
Version 2 software is not compatible with data files from
V1.31c and earlier, and does not support older ACR loggers.
A cable is included with the TrendReader TR-WIN-SRP
item above.
Cables can be purchased separately if required.
The interface
electronics (RS232 or USB) is built into the cable connector.
The cable also
includes a decoder & hardware lock (dongle) for the ACR Systems products they
are used with.
The 3.5 mm stereo plug connection to the SmartReaders &
Nautilus loggers, uses three (3) connections.
The ring, tip & sleeve connections
are signal, power, & com/gnd.
The signal connection handles both transmit & receive signals, and to do that, the interface cable electronics ensures only TX or REC signals are on line at any one time.
In addition to that, the IC-102 interface cable is serialised. Each IC-102 has a unique serial number.
This means it can only be used on the PC or laptop to which it was installed.
If used on a another PC or laptop, it must be reinstalled, even if that PC
has used another IC-102 previously.
Why all this security? Data is valuable,
and ACR Systems assist as much as possible to ensure data collected with their
logger range is as secure as possible.
IC-101 RS232 serial interface
cable is used on . . .
SmartReaders, SmartReader Plus, Nautilus loggers, XT Stickon loggers
$232+GST
DB9F serial
connector for computer (25 pin adaptor also supplied),
and
has jackplug (ring tip & sleeve 3.5mm) for ACR logger, with electronic interface,
cable is 1m long.
An RS232 to USB Converter (USB-100
$68+GST) may be used for USB connection to the computer.
IC-102 USB
interface cable is used on . . .
SmartReaders,
SmartReader Plus, Nautilus loggers $232+GST
LIC-101
RS232 serial optical interface cable is used on . . .
Owl
logger, & PowerWatch loggers.
The following loggers do not use an interface
cable, but plug directly into a laptop or PC RS-232 serial port.
JR-1000
loggers & TRH-1000 loggers.
ACRSB-INT RS232 serial interface cable is used on SmartButton loggers only.
USB-100 USB to
Serial converter cable: $68+GST
All ACR loggers that use a serial interface
cable can be used in co-ordination with this cable.
All ACR loggers
that plug directly into an RS-232 serial port without the need for a special interface
cable,
can be used in co-ordination with a USB-100 USB to Serial converter
cable.
Time stamping of Readings
in ACR Data Loggers
All ACR loggers have
an accurate clock, but not a real time clock. Data is time referenced when the
data is downloaded, from the time and date of the computer. The PC being used
should have it's clock set accurately (automatic via internet with Windows XP).
Time references can be adjusted with the TrendReader software.
Nautilus85 can stand up against harsh environments. Nautilus85
Data
Nautilus135 with high temperature capabilities
135°C, make it the ideal logger for extreme environments.
Monitor high temperatures,
where conventional data loggers aren't able to survive. zwh
Nautilus loggers only use the IC-101 RS232 serial interface cable.
For
USB interface, use the USB-100 USB to Serial converter cable: $68+GST
All
ACR loggers that use a serial interface cable can be used in co-ordination with
this cable.
Nautilus Specs common to both Nautilus loggers Specs common to both Loggers (.pdf, Esis site)
Operating Range: -40°C to 85°C. Resolution: 0.4°C, Sensor Accuracy: +/-0.2°C.
@ 25°C,
Memory Size: 32 KB, Accessories: None, No. of Channels: One. (Ambient
temperature)
Nautilus85
& 135 Specs (.pdf file, opens in new tab)
Sensor
Type: Negative Temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25°C
With Aluminium Case: $522+GST, with
SS Stainless Steel Case: $601+GST
Also requires: TrendReader Express software (see above)
Autoclaves
work by allowing steam to enter, then maintaining the pressure at 103 kPa (1.03 bar,15 psi).
This causes the steam to reach 121 °C, and this is maintained for at least 15 minutes.
Modern autoclaves operate at higher temperature and
pressures. Information about Autoclaves (Wikipedia)
Conversion: 1 bar = 100kPa = 14.5psi
Nautilus135 - for AutoclavesDesigned
for autoclaves and can also be used in other applications.
Pressure rating:13,800kPa,
13.8 bar, 2000psi
Operating Range: 10°C to 135°C. Resolution: +/-0.2°C @ 25°C,
Sensor Accuracy: +/- 0.5°C @ 77°C,
Memory Size: 32 KB, Accessories: None,
No. of Channels:
One (Ambient Temperature),
Sensor Type: Negative temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25C
Nautilus Specs common to both Nautilus loggers
Nautilus85
& Nautilus135 Specs (.pdf from Esis site) Nautilus
Data (ACR site) (these links open in new tabs)
With Aluminium Case: $522+GST, with SS Stainless Steel Case: $601+GST
Also requires: TrendReader Express software (see above)
TrendReader Express Software package (for Nautilus & JR1000), with serial cable: $182+GST
Time
stamping of Readings in ACR Data Loggers
All ACR loggers have an accurate clock, but not a real time clock. Data is time
referenced when the data is downloaded, from the time and date of the computer.
The PC being used should have it's clock set accurately (automatic via internet
with Windows XP).
Time references can be adjusted with the TrendReader software.
See also Escort High Temperature Loggers
Monitor
and record essential voltage disturbance information from any 220/240 volt Australian,
European or UK power receptacle.
Single phase, Hot to Neutral or Neutral to Ground. Surge,
Sag & Outage, Impulse, Frequency, Time.
Set up your pre-determined disturbance threshold values or use the industry standard default values, and plug it in.
Applications: Auditing medical instrumentation, point-of-sale terminals, computer servers, and other sensitive electronic equipment.
PowerWatch 120V Data (there is no data sheet specifically for the 220/240V model)
PWV002 PowerWatch 220/240V: $970+GST
PWV100 Software for Powerwatch: $332+GST
The ACR SMARTBUTTON comes with a one-year warranty, has a 10-year battery life,
has the ability to record over 2000 data points.
It operates in a temperature
range of -10°C to 85°C (+14°F to 185°F). Accuracy: 0 to 70°C: ±0.5°C
The ACR SMARTBUTTON READER software
is packed full of features including user selectable sampling rates, programmable
alarm thresholds, graph zooming and start delay. SmartButton
Data: click here
Each logger has its own unique serial number.
Files from data loggers will actually reference this number.
When saving
a data file, the name of the file will default to the serial number of the logger
that it originates from.
As soon as you clear the logger (or save a set-up
to the logger) it starts recording.
You can use the "Start Delay"
feature of the logger and set the logger to start at a particular date and time.
The logger will continue recording and if the option "Stop when full"
is enabled, it will stop recording (when the memory is full).
Otherwise the
logger will continue recording and will overwrite the oldest data (when the memory
is filled up).
Starter Kit: consists of 2 SmartButtons, CD of software, interface cable & minimanual: $315+GST
Interface Cable: $120+GST
Software CD: $15+GST
SmartButtons: 1-10: $115+GST, 11 to 25: $99+GST, 26 to 50: $85+GST
See also Disklog Temperature Loggers
Hazard Analysis and Critical Control Points (HACCP) is a systematic preventive approach to food safety and pharmaceutical safety that addresses physical, chemical, and biological hazards as a means of prevention rather than finished product inspection.
For details see http://en.wikipedia.org/wiki/HACCP
There is no such thing as HACCAP accreditation or approval for specific equipment.
If applicable, please check the HACCAP manual to see what specifications are appropriate
for your application.