Information about 4-20mA Current Loops
| HMI41
Relative Humidity and Temperature Indicator, hand held. 2-line LCD display. | |
| Data on HM70 HMI41 HM34 HM44 (Vaisala site) Probes for HMI41 (see back of HMI 41 data sheet): HMP41 Humidity and Temperature
Probe HMP42 Humidity and Temperature Probe for small
spaces (4 mm diameter probe head) for use with HMI41 indicator. HMP45 Humidity and
Temperature Probe with handle and 1.5m spiral cable for HMI41 indicator. HMP46
Humidity and Temperature Probe with handle and 1.5m spiral cable for HMI41
indicator. |
HMI41 OptionsHM36736 Carry Case for HMI 41& HMP41/45 probes $75 5/11 210614 Rigid Plastic Carry
Case Calibration cables for HMI 41 Hum & Temp indicator 19116ZZ For use with HMD/W 60/70 and HMP140 series transmitters $53 19164ZZ For use with HMP230/240 series transmitters $85 19165ZZ For use with HMD/W20/30 and HMP130 series transmitters $85 25917ZZ For use with HMT100 / HMT330 series transmitters $85 19446ZZ Serial interface cable for HMI41 $53 5/11 221186 USB interface cable for HMI41 $117 |
HM34C
Pocket-Size Relative Humidity and Temperature Meter Accurate and stable.
(C in the model number indicates °C).
Probe retracts into instrument.
Hold reading function, Automatic power-off.
Operating range:
-20 to +60°C.
Accuracy at 20°C: ±1% against factory reference,
±2% against field ref. (0-90%RH). 160x57mm including probe
Data
on HM70
HMI41
HM34 HM44 (Vaisala site)
HM34C
Pocket-Size Relative Humidity and Temperature Meter: $649+GST 5/11
See also Testo Instruments
Data on HM70 HMI41 HM34 HM44 (Vaisala site)
HM70 Hand Held Humidity and Temperature
Meter.
Consists of MI70AUS plus one probe from the list below.
Displays
Relative Humidity, Temperature, Dewpoint Temperature,
Mixing
Ratio, Absolute Humidity, Wet Bulb Temperature, Enthalpy & Water Vapour Pressure.
MI70AUS Indicator with backlit LCD display.
Displays up to 3 parameters
at a time either numerically or graphically.
Includes data logging and can
be used as a field calibrator for Vaisala transmitters.
Complete with rechargeable
battery and AC adapter $1426+GST
5/11
Probes for HM70
(B Version Chemical purge and sensor preheat option for HMP75, HMP76 or HMP77)
HMP75 Relative
Humidity and Temperature probe for MI70 $1075
HMP75B Relative Humidity and Temperature probe for MI70 inc chemical purge $1118
HMP76 Relative Humidity and
Temperature probe for MI70. Temperature
measurement range from -50 to +120°C.
Temporary measurements of -50 to +180°C $1447
HMP76B Relative Humidity and Temperature probe for MI70 inc chemical
purge.
Temperature measurement range from -50 to +120°C $1479
HMP77 Relative
Humidity and Temperature probe for MI70.
Temperature measurement range from
-70 to +180°C. $1979
HMP77B Relative Humidity and Temperature probe for MI70 inc chemical
purge.
Temperature measurement range from -70 to +180°C $2022
Options for HM70
MI70Case Carrying
case for MI70 + HMP75/77 (ordered separately) $298
MI70Case2 Carrying
case for MI70 + HMP75/76 (ordered separately) $500
MI70Link MI70
Windows software with RS232 cable $106
219687 USB
cable for MI70 with MI70Link Windows® software $106
HMA6070 MI70
Connection cable to 60/70/140 series transmitters $372
HMA2030 MI70
Connection cable to 20/30 series transmitters $372
27159ZZ MI70
Connection cable to HMP230 series / HMP228 $79
211339 MI70
Connection cable to HMT300 & HMT100 series $79
27168ZZ MI70
Analog output cable $53
MI70LA MI70 Link+Analog cable $170
Spares
for HM70 Options for HM70
26755 Rechargeable NiMH Battery Pack $53
MI70AUSADAPTER Mains AC-adapter, AUS model $106+GST 4/09
HMI38
Benchtop unit - NO LONGER AVAILABLE - Use HM70
above.
with inputs for 2 probes, with displays,
has 2 analog outputs & RS232/485 serial output.
Data logging function,
built-in rechargeable battery. Probes not included.
Probes for HMI 38: - NO LONGER AVAILABLE -
HMP35E with DB9M connector, Pt100 temperature sensor 4-wire, compatible with HMI 38 Humidity Data Processor. 18.5mm dia $595
HMP36E Humidity and Temperature Probe with DB9M cnctr, with composite sensor, for HMI 38. Spec. same as HMP 35.
Has metal probe 12mm dia, 325mm long, overall length 470mm. with sintered filter, 15sec response $920HMP37E Hum & Temp Probe for confined spaces with male DB9M cnnctr, for HMI 38 Humidity Data Processor.
1.5m cable between probe electronics and D connector, then 5m cable between sensor head and probe electronics, 13.5mm dia, 70mm long $1200
for monitoring the relative humidity & temp. of structural material
(e.g. in a hole in setting concrete).
The HM44 set includes the following
items:
HMI41 indicator with batteries
HMP44
Relative Humidity and Temperature probe.
Protective cover
with lid, 3 pcs (19268HM)
Rubber plugs, 12 pcs (19267HM)
Plastic sleeves, 12 pcs (19266HM)
Carrying
case (HM26849)
HM44
Structural Humidity measurement set $1330+GST 4/09
Accessories: please enquire Data
on HM70 HMI41 HM34 HM44 (Vaisala site)
Accessories
for HM44
HM26849 Carrying Case HM44 $255+GST
4/09
19266HM Plastic sleeves, 12 pcs (19266HM) $21
19267HM Rubber plugs, 12 pcs
(19267HM) $21
19268HM Protective cover with lid, 3 pcs (19268HM) $21
26529HM Plastic Flange Set $32
26530HM Long Rubber Plug Set $64
See also Testo Instruments: click here
Data
on Barometric Pressure instruments: (Vaisala site)
PTB110 PTB210 PTB330 PTB330TS PTU300
SPH10/20
(Equipped
with 1 Class B Pressure Transducer),
Relative Humidity (except PTU30T) and Temperature transmitter. No display.
Barometric pressure,
humidity and temperature measurement in one transmitter
Available with
two barometric pressure sensors - for added reliability
RS-232C serial
interface with NMEA protocol for GPS use
Optional display, RS-485,
analog output, and relay
Optional power supply module
NIST
traceable calibration
HMT330MIK Installation kit for outdoor use
Applications include environmental monitoring in calibration laboratories,
GPS meteorology: estimating precipitable water vapor in the atmosphere; weather
stations
Integrated data logging, with over four years of measured
history
LAN and WLAN communication options
Temperature measurement range: -40 ...
+60 °C
Humidity range:
0 to 100%
Barometric Pressure range: 500
... 1100 hPa, 50 ... 1100 hPa
Brochure on PTU300 (.pdf) Data on PTU300 (Vaisala site)
Order form showing options for PTU300 (.pdf)
PTU301 Barometric Pressure, Relative Humidity & Temperature transmitter for
wall mounting $3000+GST 4/09
PTU303 Barometric Pressure, Relative Humidity & Temperature transmitter for
general use $3213+GST
PTU307 Barometric Pressure, Relative
Humidity & Temperature transmitter with warmed probe for high humidities. $3926+GST
PTU30T Barometric Pressure, Temperature transmitter only $2,880
PTU300CLASSA1 Class
A / one sensor, 500...1100 hPa
PTU300CLASSA2 Class
A / two sensors, 500...1100 hPa
PTU300CLASSB2 Class
B / two sensors, 500...1100 hPa
PTU300CLASSB2LO Class B / two
sensors, 50...1100 hPa
HMP303PZ5-2 5 m cable for PTU303
HMP303PZ10-2 10 m cable for PTU303
HMP307PZ5-2 5
m cable for PTU307
HMP307PZ10-2 10 m cable for PTU307
TPROBE2
5 m cable
for PTU30T
TPROBE3 10
m cable for PTU30T
213886 Additional T probe with 2 m cable
for PTU307
213888 Additional T probe with 5 m cable for
PTU307
213889 Additional T probe with 10 m cable for PTU307
Options HMT330LD Graphic LCD with backlight |
Accessories for PTU300 series 214829 Wall Mounting Kit |
PTB330CLASSA PTB330 Digital Barometer
(500 to 1100hPa), (Class A, equipped with 1 pressure transducer) $2660+GST 4/09
PTB330CLASSB PTB330 Digital Barometer (500 to 1100hPa), (Class B, equipped
with 1 pressure transducer) $2309+GST
Options for PTB330 BARO-1-3 Additional 2nd pressure transducer(500...1100
hPa) | Spare parts & accessories 214829 Wall Mounting Kit |
Data
on Barometric Pressure instruments: (Vaisala site)
PTB110 PTB210 PTB330 PTB330TS PTU300
SPH10/20
PTB330TS Barometric Pressure Transfer Standard (500 to 1100hPa),
(Class A, equipped with 1 pressure transducer) $5277+GST 4/09
Includes portable tabletop enclosure, PTB330CLASSA barometer & MI70 indicator
1Additioncell Additional pressure transducer
2Additionallcells
Two additional pressure transducers
MI70LINK options
MI70LINK
Serial cable for MI70 with MI70Link Windows software
219687 USB cable for
Mi70 with Mi70Link Windows® software
Optional temperature and humidity
probe for PTB330TS
HMP155 RH&T probe for PTB330TS
Composite sensor
upgrade (Humicap180RC)
Additional T probe with 2m cable
MI70 connection
Cable
Case with foam
Tubing fitting for 1/8"
hose
Quick connector with shutoff valve for 1/8" hose
M12 spiral
cable(MI70 - PTB330)
Table top casing
Data
on Barometric Pressure instruments: (Vaisala site)
PTB110 PTB210 PTB330 PTB330TS PTU300
SPH10/20
PTB210
Digital Barometric Pressure Transmitter, Measuring range 500...1100hPa or 50 ..1100hPa,
Power supply 5
28VDC. Supplied with 1m cable.
PTB210CLASSA
Digital Barometer with RS232 Serial Output, Class A $2234+GST
4/09
PTB210CLASSB Digital Barometer with RS232 Serial
Output, Class B $1894+GST
PTB210CLASSC Digital Barometer
with Analog Output, Class C $1543+GST
PTB210RS
RS485 Serial Communication Module for Class A & B models
PTB210CAB2 2
m Cable
PTB210CAB3 3 m Cable
PTB210CAB5 5 m Cable
PTB210CAB10 10 m
Cable
PTB110 Barometric barometer with
NIST traceable calibration certificate
Choose from one of the following pressure
ranges:
500
1100, 600
1100, 800
1100, 600
1060, 800
1060
hPa
Choose from one of the following outputs:
0
5VDC, 0
2.5VDC
or frequency output(1hPa=1Hz) $1096+GST 4/09
PTBINSTALL1 DIN rail installation
kit
PTB110CONB Quick connector with shutoff valve for 1/8''
hose
SPH10 Static Pressure Head $532+GST
4/09
SPH20 Static Pressure Head ( Heated )
$1468+GST
Data
on Barometric Pressure instruments: (Vaisala site)
PTB110 PTB210 PTB330 PTB330TS PTU300
SPH10/20
PTB220TS
is an all in one portable unit that can be
used as a portable barometer,
as a transfer or travelling standard and as
a laboratory working standard.
Accessories for Vaisala Pressure instruments
PMI20
Digital Barometer Display - NO LONGER AVAILABLE
-
PMI20 can simultaneously show various values,
such as the barometric pressure, the pressure trend and the WMO pressure tendency
code.
Ideal for manned weather stations and laboratories. It has both an
RS232 and an RS485 connection to the barometer and PC.
Moreover, as the RS485
allows a distance of up to one kilometer between the barometer and the display,
the display may be used as an in-house remote display to a barometer installed
outdoors. Five open collector -type control outputs are offered
with the display.
The display is compatible
with all Vaisala's current barometers with a serial output as well as with the
PTU200 Transmitter.
PTU200MIK1 Outdoor
Installation Kit - NO LONGER AVAILABLE
-
PTU200MIK is a high-quality mounting kit for
outdoor use of PTU200. It allows meteorological measurements to be made on site,
e.g. next to a GPS antenna.
Humidity & Temperature - Vaisala
Response time (to 90% final rdg.) after a step change from 0%
to 75% RH: No
need for re-calibration Humidity
Instruments (Vaisala site, opens new tab or window) | ![]() |
The HUMITTER 50 series has been replaced with
the HMP50 series which has similar specifications.
Differences are as follows:
0-1V,
0-2.5V and 0-5V output options available, Aluminium body
Cable
attaches via a miniature connector at base of sensor
Miniature-size
humidity transmitter
Very low power consumption
Short power-up
time
Measurement range 0...98 %RH and -10...+60 °C
Cable
detachable with standard M8 quick connector
Rugged metal housing
Interchangeable Vaisala INTERCAP® Sensor
Optional outputs
and cable lengths
Dimensions: 71mm long, x 12mm dia
Data on HMP50 series (.pdf file, opens in new tab) Data from Vaisala site
HMP50 Ordering Options (.pdf file, opens in new tab)
HMP50U Integrated RH transmitter,
incorporates INTERCAP® interchangeable relative humidity sensor.
Power
supply 7...28 VDC.
Available outputs: 0...1V, 0 ... 2.5V, 0 ... 5V, (please
specify output when ordering ) Cable not included $255+GST 4/09
See ordering options link above
Option: Current interface 4-20mA requires 26182HM Current output converter kit (see below)
HMP50Y Integrated RH and T transmitter,
incorporates INTERCAP® interchangeable relative humidity sensor, PT1000
temperature sensor.
Power supply 7...28 VDC.
Available outputs: 0...1V,
0 ... 2.5V, 0 ... 5V, (please specify output when ordering) Cable not included
$340+GST 4/09
See ordering options link above
Also
required, cable:
HMP50Z032 cable, 0.3 m, with 4-pin
M8 connector for HMP50 (see below)
HMP50Z300 cable, 3.0
m, with 4-pin M8 connector for HMP50
HMP50Z032
Shielded Cable, 0.32m, 4-pin M8 Female Straight $16+GST when ordered with the
HMP50 4/09
HMP50Z300 Shielded Cable, 3.0m, 4-pin
M8 Female Straight $32
HM46670HMP50 Stainless Steel sintered filter for
HMP50 $75
Current output converter kit (for I interface)
26182HM U/I conversion component kit ( for HMP50UD only ) $11
18350 Pair of plastic nuts M12 x 1 F.O.C. no charge if specified with the sensor
HMP50 Spare Parts
HMP50Z032SP Shielded Cable, 0.32m,
4-pin M8 Female Straight $26+GST 4/09
HMP50Z300SP
Shielded Cable, 3.0m, 4-pin M8 Female Straight $42
Other Options & Accessories
for HMP50 Series (from data sheet)
Vaisala INTERCAP® sensor 15778HM
(spare)
Vaisala INTERCAP® sensor with membrane 15872HM (spare)
Sensor
protection:
DRW010522 Plastic grid (spare)
DRW010525 Membrane filter (spare)
See
also HMD40 / HMD50
Humidity & Temperature Transmitters for HVAC Applications, below: click
here
50U & 50Y HUMITTER Series
- superceded by HMP50
- see above
The
HMP60 is a simple, durable and cost-effective humidity probe. It is suitable for
volume applications, integration into other manufacturers equipment, incubators,
glove boxes, greenhouses, fermentation chambers, and data loggers.
Easy
installation
The probe cable has a screw-on quick connector for easy installation.
Different cable lengths are available. Also other compatible M8 series cables
can be used. Accessories are available for different installation needs. Low current
consumption. The HMP60 is suitable for battery powered applications because of
its very low current consumption.
Several outputs
There are two configurable
voltage outputs with relative humidity, temperature or dew point scaling.
Four voltage output ranges are available.
Rugged design
The HMP60
is designed for extreme conditions. The aluminum body of the HMP60 is classified
as IP65. The probe has a sealed structure and the sensor is protected by a membrane
filter and a plastic grid, or optionally by a stainless steel filter.
Recalibration
not needed
The Vaisala INTERCAP® Sensor is interchangeable. No recalibration
is required; the sensor can simply be replaced, also in the field.
Features/Benefits
*
Miniature-size humidity probe
* Low power consumption
* Measurement range:
0 ... 100 %RH; -40 ... +60°C
* Cable detachable with standard M8 connector
* Rugged metal housing
* Interchangeable Vaisala INTERCAP® Sensor
* Optional RS485 digital output, Optional dew point output
* Applications:
volume applications, integration into other manufacturers equipment, glove
boxes, greenhouses, fermentation chambers, data loggers
Inputs and outputs
Operating
voltage (Use lowest available operating voltage to minimize heating.)
5...28
VDC / 8...28 VDC with 5 V output
8...28VDC with loop power converter
Current
consumption 1 mA average, max. peak 5 mA
Start-up time at operating voltage
<14 V: 1s; >14 V: 4s
Outputs
2 channels 0...1 VDC
/ 0...2.5 VDC / 0...5 VDC / 1...5 VDC
1-channel loop-power converter (separate
module, compatible with humidity accuracy only) 4...20 mA
digital output (optional):
RS485 2-wire half duplex
External loads 0...1 V RL
min 10 kOhms
0...2.5
V / 0...5 V RL min 50 kOhms
Data
sheet on HMP60 (pdf file, opens in new tab or window)
The HMP110 is a trouble-free and cost-effective humidity
transmitter with high accuracy and good stability. 
It
is suitable for volume applications or integration into other manufacturers
equipment.
The HMP110 is also suitable for glove boxes, greenhouses, fermentation
and stability chambers, data loggers, and incubators.
Easy installation
The
probe cable has a screw-on quick connector for easy installation. Different cable
lengths and accessories are available.
Low current consumption
HMP110
is suitable for batterypowered applications because of its
very low current
consumption. It also has a fast start-up time.
Several outputs
The temperature
measurement is a standard feature, dew point measurement is optional.
Three
standard voltage outputs are available.
Robust design
The aluminum
body of the HMP110 is classified as IP65. Thus, it survives rough conditions.
The HMP110 has high chemical tolerance because of the HUMICAP® 180R sensor.
Easy
maintenance
Maintaining measurement traceability is easy using the HMP110R
replacement probe. We send you a replacement probe, you
detach the old probe
and send it back to us. In this way the measurement is available at all times
without interruptions.
Features/Benefits
* Miniature-size humidity transmitter
* Low power consumption and fast startup for battery powered applications
* Measurement range: 0 ... 100 %RH; -40 ... +80°C
* Cable detachable with
standard M8 quick connector
* Reliable: Latest generation HUMICAP® 180R
sensor for best stability and high chemical tolerance. IP65 metal housing.
* Optional RS485 digital output
* Traceable: Comes with calibration certificate.
±1.7%RH measurement accuracy(0 ... 90%RH)
* HMP110R replacement probe
service available for easy maintenance
* Optional dew point calculation
Inputs
and outputs
Operating voltage (Use lowest available operating voltage to
minimize heating)
5 ... 28 VDC / 8 ... 28 VDC with 5 V output
8 ... 28 VDC
with loop power converter
Current consumption 1 mA average, max. peak 5 mA
Start-up
time at operating voltage <14 V: 1s >14 V: 4s
Outputs
2
channels 0...1 VDC / 0...2.5 VDC /
0...5
VDC / 1...5 VDC
1-channel loop-power converter (separate module, compatible
with
humidity accuracy only) 4 ... 20 mA
digital output (optional) RS485 2-wire
half duplex
External loads 0...1 V RL
min 10 kOhms
0...2.5
V / 0...5 V RL min 50 kOhms
Data
sheet on HMP110 (pdf file, opens in new tab or window)
Vaisala HUMICAP®180R sensor - superior long-term stability
Optional
warmed humidity probe
Plug-and-play
Chemical purge
USB connection
for service use
Installation kits for DTR13 and DTR502 radiation shields
and also for a Stevenson screen
Weather-proof housing IP66
New, fast
temperature probe
Different output possibilities: voltage, RS-485, resistive
Pt100
Applications: meteorology, aviation and road weather, instrumentation
Relative humidity measurement:
Measurement range 0
... 100 % RH
Accuracy (incl. non-linearity, hysteresis and
repeatability) at +15
+25 °C
±1
% RH (0 ... 90 % RH), ± 1.7 % RH (90 ... 100 % RH)
For other temperatures,
please see the the brochure
Recommended humidity sensor: Vaisala HUMICAP®
180R
Temperature measurement:
Measurement range: -80
... +60 °C
Accuracy at +20 °C: voltage: ±0.17
°C RS485: ±0.12 °C
passive
resistive output: according to IEC751 1/3 Class B
Temperature sensor: Pt100
RTD
Optional additional T probe
Other variables: dewpoint/frost point
temperature; wet bulb temperature, mixing ratio
Operating
environment: Temperature: Operation: -80 ... +60°C. Storage:
-80 ... +60°C
Inputs and outputs:
Operating voltage: 7 ...
28 VDC
Outputs
voltage output: 0 ... 1V, 0
5
V, 0
10 V
resistive Pt100 (4-wire connection)
RS485
Mechanics:
Connection cables: 3.5,
10, and 30 m
Material (housing): PC
Housing classification: IP66
Brochure on HMP155 (.pdf) (pdf files, open in new tabs)
HMP155 Order form showing the options HMP155 User Guide
HMP155A Humidity and temperature probe, 2 voltage outputs
(RS485for service use) $809+GST 4/09
HMP155D Humidity and temperature probe,
voltage output for humidity
& 4- wire Pt100 RTD output for temperature (RS485 for service use) $734
HMP155E Humidity and temperature probe, RS485 interface only $809
Cables
to suit HMP155 series:
HMP155CABLE3.5M 3.5m cable with 8 pin M12 female
connector $53
HMP155CABLE10M 10m cable with 8 pin M12 female connector $85
HMP155CABLE30M 30m cable with 8 pin M12 female connector $202
Warming/heating
and additional temperature probe options
HMP155HEATEDPROBE Warmed probe
(only with composite sensor) $436
HMP155XHEATEDPROBE Warmed probe + Xheat
(only with composite sensor) $436
HMP155ADDITIONALT Additional T-probe with
2m cable upgrade $170
HMP155H180RC Composite sensor upgrade $43
HMP155H180C
Composite sensor upgrade $43
| Accessories | Spare
parts 220496 Connection Cable 3.5m 8-pin M12 $53 220497 Connection Cable 10m 8-pin M12 $85 220498 Connection Cable 30m 8-pin M12 $202 219452SP Sintered Teflon Filter + O-ring $75 221318 Protection Set for Calibration Buttons $32 |
A replacement for the HMP45A is: HMP155-A2GB11A0A1A1A0A
$861+GST 4/09
including: - two 0..1VDC
outputs
- 3.5m cable
- Improved Humicap 180R sensor
A replacement
for the HMP45D is: HMP155-D2AB11A0A1A1A0A$740+GST 4/09
including: - RH = 0..1VDC output, T = 4-wire Pt100 output
- 3.5m cable
- Improved Humicap 180R sensor
For connection to data
loggers, etc.
Operating range: -40 to
+60°C. Req 7..35VDC.
RH
output: 0-1V output. Has calibration adjusters.
Acc. at 20°C
incl. linearity & hysteresis:
±1%RH against factory
ref., ±2% against field ref. 0-90%RH, (±3% to 100%)
Temp. dependence 0.05%RH/°C. Response
time (90%) 15 sec with membrane filter.
Overall length 235mm,
plastic with grill at probe end.
Temperature: Pt1000 1/3
DIN 43760B sensor and amplifier provided in probe. -40 to +60°C,
Output: 0 to 1VDC. Acc 0.2° at 20°C. Req 7..35VDC. Supplied without connector
(7 wires show at end of cable).
Cable 3.5m with bared wires at end. Removable
probe electronics. CE approved. Calibration. Certificate traceable to NIFT (UK)
Supplied without connector (5 wires & shield show at end of cable)
Brochure
on HMP45A & HMP45D (.pdf, opens in new tab))
User Guide (.pdf, opens in new tab)
HMP45A Humidity and Temperature Probe without connector,
linear 0...1 VDC output signals for relative humidity and temperature: $809+GST
4/09
HMP45D
similar to HMP 45A except there is no amplifier for temperature, uses resistive
Pt100 sensor, more accurate than HMP 45A,
linear 0...1 VDC output signal
for relative humidity, four wire connection provided. Replaces the old HMP35A
Supplied without connector (8 wires & shield show at end of cable) $809+GST
4/09
Extra Cable at time of ordering probe:
removal of normal cable and installation
of new longer cable: $6/m, minimum $36 (for 6m or less)
DTR Solar
Radiation & Precipitation Shields
DTR503A Radiation Shield for HMP45A/D
$532+GST 4/09
DTR503B Radiation
Shield for HMD60Y $553
DTR502B Radiation
Shield for HMP233 $638
DTR13 Radiation
shield suitable for various probes $958
13303 Radiation
shield for above: Multi-plate (louvred),
21cm high, 12cm dia, with one probe mounting gland.
Bracket & U-bolt
for mounting on vertical pipe 25-50mm dia.
for HMP45A (HMP35A) or HMD60Y
For Fixed Installation
Rugged Humidity & Temperature Transmitters for industrial & control applications. Please enquire.
Intrinsically Safe Transmitters: Humidity / Humidity & Temperature
HMT 360 Series see below.
Raytek
Thermalert TX: IR sensors with 4-20mA output (for mounting)Two
wire loop powered, IP65 head
Optional protective windows
also Smart versions
with RS232 comms interface, Alarm 24V 150mA, adjustable set points
Optional
smart HART version with windows software
New sighting heads and laser sight
heads
More
Data on Fixed IR Thermometers (this site)
Prices (Australian dollars) may change without notice
| Distance : Dia of spot | Temp
range | w/o GST | |
| RY-TXC-LTP-SF |
15:1 | -18 to 500°C |
$1534 |
| RY-TXC-LT-SF Low Temp | 33:1 |
-18 to 500°C | $1830 |
| RY-TXC-MT-SF Medium Temp | 33:1 |
200 to 1000°C | $2336 |
| RY-TXC-HT-SF High Temp | 60:1 |
500 to 2000°C | $2407 |
Hand held IR Temperature Instruments: click here (thid site)
HI 8666 Compact Relative Humidity
& Temperature Transmitter with two 4-20 mA outputs HI8666
gzm
Ranges: 0%
(4 mA) to 100% RH (20 mA), -20°C (4 mA) to +60°C (20 mA) Data:
click here HI 8666: $600+GST
Abbreviations:
RH - Relative
Humidity | T - Temperature | Td - Dewpoint Temperature
| TW - Wet Bulb Temperature |
x - Mixing Ratio (g of
moisture / kg of dry air) | a- Absolute Humidity (g / m3) |
h - Enthalpy (kj/kg) |
NDIR - Non dispersive infrared
Data
on fixed Humidity Transmitters (Vaisala site)
HMD330 HMT360 HMT100
HMD60 HMW60 HMD70 HMW70
HMD40 HMW40 HMD50
HMW50 HMW80 replaces the HMW40/50 Series
HMT300TMK
HMW60U Two-wire Humidity Transmitter for wall mounting,
features
4...20mA output signal, power supply 10...35VDC, one-point electronic humidity
calibration $427+GST 4/09
HMW60Y
Two-wire Humidity and Temperature Transmitter for wall mounting,
features
4... 20mA output signals,
power supply 10...35VDC, one-point electronic humidity
calibration $575
HMW70U Three wire Humidity Transmitter for wall mounting,
features
selectable output signal (0...1V, 0...5V or 0...10V, factory setting 0...1V),
power supply 10...35VDC, 9...24VAC, one-point electronic humidity calibration
$427
HMW70Y Three-wire Humidity and Temperature Transmitter for wall
mounting,
features selectable output signal (0...1V, 0...5V, or 0...10V,
factory setting 0...1V for both humidity and temperature),
power supply 10...35VDC,
9...24VAC, one-point electronic humidity calibration $575
HMD60U Two wire Humidity
Transmitter for duct mounting,
features 4...20mA output signal,
power
supply 10...35VDC, membrane filter, one-point electronic humidity calibration
$575
HMD60Y Two-wire Humidity and Temperature Transmitter for duct mounting,
features 4... 20mA output signals,
power supply 10...35VDC, membrane
filter, one-point electronic humidity calibration $713
HMD70U Three-wire Humidity
Transmitter for duct mounting,
features selectable output signal (0...1V,
0...5V or 0...10V, factory setting 0...1V),
power supply 10...35VDC, 9...24VAC,
membrane filter for sensor protection, one-point electronic humidity calibration
$575
HMD70Y Three-wire Humidity and Temperature Transmitter
for duct mounting,
features selectable output signal (0...1V, 0...5V or 0...10V,
factory setting 0...1V for both humidity and temperature,
power supply 10...35VDC,
9...24VAC, membrane filter for sensor protection, one-point electronic humidity
calibration $713
18945HM 0...20mA Current module for HMD70 $75+GST 4/09
Data
on fixed Humidity Transmitters (Vaisala site)
HMD330 HMT360 HMT100
HMD60 HMW60 HMD70 HMW70
HMD40 HMW40 HMD50
HMW50 HMW80 replaces the HMW40/50 Series
HMT300TMK
HMW60T Two-wire Temperature Transmitter
for wall mounting, features 4...20mA output signal,
power supply 10...35VDC.
$404+GST 4/09
HMD60T Two wire Temperature
Transmitter for duct mounting, features 4...20mA output signal,
power supply
10...35VDC, membrane filter. $543
HMW70T
Three wire Temperature Transmitter for wall mounting,
features selectable
output signal (0...1V, 0...5V or 0...10V, factory setting 0...1V),
power
supply 10...35VDC, 9...24VAC. $404
HMD70T Three-wire Temperature Transmitter for duct mounting, features
selectable output signal (0...1V, 0...5V or 0...10V, factory setting 0...1V),
power supply 10...35VDC, 9...24VAC. $564
Designed
for humidity and temperature monitoring in demanding HVAC applications.
Features
two-wire loop powered or three-wire voltage output configurations, an interchangeable
probe, and an optional display.
Full 0 ... 100 %RH measurement
Two-wire
loop-powered or three-wire voltage output con?gurations
Fixed and remote probe
models
Display available
Relative humidity, dewpoint, temperature outputs
Vaisala HUMICAP® sensor
Interchangeable probe module for minimal maintenance
downtime
Different output scalings
Compatible with hand-held HM70 and
HMI41 for one-point calibration
IP65 (NEMA 4) housing
NIST traceable (certificate
included)
HMT100
Brochure (.pdf, opens in new tab) HMT100
Order Form showing Options (.pdf, opens in new tab) HMT100
Data (Vaisala site)
| Relative humidity measurement HMT100 Sensor: Vaisala HUMICAP® 180 Temperature measurement | Operating environment Inputs and outputs Voltage output signals: 0 ... 1 V, 0 ... 5 V, 0 ... 10
V |
HMT100
Series Transmitters
HMT100A Wall mount/fixed probe $511+GST
4/09
HMT100B Remote probe with 3 m cable
$692
HMT100C Remote probe with 5 m cable $713
HMT100D Remote probe with
10 m cable $755
HMT100E Remote probe with 10 m + 10 m extension cable $872
HMT100LCD Single line LCD Display
(Displays 2 parameters only if HMT100OP2
selected). $138
HMT100OP2 Two output parameters (2nd analog channel) $138
Accessories
DRW010699 Wall mounting plate (Aluminum) $43
215109 Outdoor installation kit (Weather shield) $170
215619 Duct installation
kit $11
HMT100DTR502B DTR502 with probe installation kit $638
Spare
parts
HMP100 Spare probe for HMT100 $309
DRW220095 Shielded Extension
Cable, 10.0 m, 4-pin M8 $106
Note: Each HMT100 includes a plastic wall mounting
adapter
HMW61/71 Humidity
& Temperature Transmitters for Industrial/HVAC Applications
- superceded by HMT100 above
HMW82 HMW83 TMW82 TMW83
HMW80 replaces HMW40/50 Series
The HMW80 is available in four different versions:
▪ TMW82: 4–20mA (temperature only)
▪ TMW83: 0–10V (temperature only)
▪ HMW82: 2x 4–20mA (relative humidity and temperature)
▪ HMW83: 2x 0–10V (relative humidity and temperature)
▪ Cost-efficient, dependable
solution for humidity and
temperature measurement for
heating and ventilation
▪ Measurement range
0 ... 100 %RH and -5 ... +55 ˚C
▪ Stable and dependable
▪ Combines excellent stability
with easy installation and
reliable operation
▪ Fits EU/US/JPN junction boxes
▪ 2-year warranty
▪ No recalibration required
▪ UL-V0 approved materials
used
The two- and three-wire Vaisala
INTERCAP® Humidity and
Temperature Transmitter Series
HMW80 is designed for use in energy
management systems in buildings.
Temperature Measurement range -5 ... +55 °C
Relative humidity
Measurement range 0 ... 100 %RH
Outputs: 4 ... 20mA, loop powered
Data sheet on HMW80 Series (pdf file, opens new tab or window)
HMW80 replaces HMW40/50 Series
HMW82 Wall mount RH & Temp Transmitter (±3%RH) $155+GST 4/11
HMW83 Wall mount RH & Temp Transmitter (±3%RH) $155
TMW82 Wall mount Temperature only Transmitter $109+GST
TMW83 Wall mount Temperature only Transmitter $109
The
Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 are
designed for humidity and temperature monitoring in cleanrooms and are also suitable
for demanding HVAC applications.
The HMT120/130 transmitters use a fully
interchangeable relative humity probe.
The probe can be easily removed and
replaced with a new one without having to adjust the transmitter, which allows
for easy and quick recalibration of the transmitter.
The probe can be adjusted
using one of Vaisala’s portable meters as a reference.
Also available is a
constant output probe with fixed RH and T output for convenient inspection of
the monitoring system and signal transfer line.
Features & Benefits
Vaisala
HUMICAP® technology with humidity sensor HUMICAP ® 180R
2-wire loop-powered
or 3-wire voltage output configurations
Interchangeable probe (easy field calibration)
Accurate
and reliable
Resistant to dust and most chemicals
Optional LCD display
USB
cable available for a PC connection for maintenance
Wall-mounted or with a
remote probe
Constant output probe available
Can be mounted outdoors using
a Vaisala installation kit and the Vaisala Radiation Shield DTR502B
Enclosure
IP65
Suitable for cleanrooms and demanding HVAC applications
Measurement
range -40 °C ... +80 °C
Available Options The HMT120 and HMT130
transmitters are available as wall mounted or with remote probe.
For high
temperature applications or where space is limited, the remote probe is ideal.
The transmitters come with an optional, LCD display, which shows the measurement
results of selected parameters in selected units. The parameters are displayed
simultaeously at two separate rows on the display.
Data
sheet on HMT120 & HMT130 (pdf file, opens in new tab or window)
Accessories
Humidity
and temperature probe HMP110*
Humidity and temperature replacement
probe HMP110R*
Constant output probe HMP110REF*
Humidity sensor
HUMICAP® 180R
Probe
mounting flange 226061
Probe
mounting clamps, 10 pcs 226067
HMP110 sensor protection
plastic
grid filter DRW010522SP
plastic
grid with membrane filter DRW010525
stainless
steel sintered fi lter HM46670SP
Probe
cable 3 m HMT120Z300
Probe cable 5 m HMT120Z500
Probe
cable 10 m HMT120Z1000
Radiation shield DTR502B
Probe
installation kit for DTR502 210623
Rain shield with installation
kit 215109
Duct installation kit
215619
HMI41 connection
cable 25917ZZ
HM70 connection cable 211339
USB
serial interface cable 219685
HMW40/50 Series is replaced by the HMW80 Series above
Data
on fixed Humidity Transmitters (Vaisala site)
HMD330 HMT360 HMT100
HMD60 HMW60 HMD70 HMW70
HMD40 HMW40 HMD50
HMW50
HMT300TMK
(conforms to SA classification Ex ia IIC T5 IP65, AUS Ex 3738X).
These are currently not certified in Australia for intrinsic safety.
One 4...20
mA analog output signal, power supply 12 .. 24 VDC
Data
on HMT 360 Series: click here (Vaisala site)
Complete unit ( transmitter & probe
)
HMT361 Wall Mount transmitter for RH + T measurement. Temperature range
-40 to + 60°C $2,650 2006
HMT363 Small Probe head transmitter for RH + T measurement. Temperature range - 40 to + 120°C $2,950
HMT364 High Pressure transmitter for RH + T measurement. Temperature range - 40 to + 180°C $4,100
HMT365 High Temperature transmitter for RH + T measurement. Temperature range - 40 to + 180°C $3,580
HMT368 Pipeline installation transmitter for RH + T measurement. Temperature range - 40 to + 180°C $3,820
Spare Probes
HMP361 Probe for Wall Mounting $860 2006
HMP363 Small Probe $1,160
HMP364 Probe for High Pressures
$2,350
HMP365 Probe for High Temperatures $1,780
HMP368 Probe for Pipeline
Installations $2,030
Options for HMT360 series
HM360AOUT1 second
analog output $150
HMT360LD Display on cover $180
HMT360CP7 Additional
output variables Td + a + Tw + x $630
HMP233PHZ5 5 metre extended cable for
HMT363 $185
HMP233PHZ10 10 metre extended cable for HMT363 $390
HMP234PZ5
5 metre extended cable for HMT364 $195
HMP234PZ10 10 metre extended cable
for HMT364 $460
HMP235PZ5 5 metre extended cable for HMT365 $190
HMP235PZ10
10 metre extended cable for HMT365 $440
HMP235FS Mounting flange, Stainless
Steel $80
HMP235FA Mounting flange, aluminium $35
HMP233FAH Duct installation
kit for HMT363 $55
Top-of-the-line
model for demanding industrial applications.
A large numerical and graphical
display. A fully configurable transmitter.
Six models for demanding applications:
HMT331 for wall mounting
HMT333 for duct
mounting and tight spaces
HMT334 for high pressures up to
100 bar and vacuum conditions
HMT335 for high temperatures
HMT337 for high humidity and meteorological applications
HMT338 for pressurized pipelines up to 40 bar
Full 0...100
%RH measurement, temperature range up to +180 °C (+356 °F), depending
on model
Vaisala HUMICAP® Sensor for excellent accuracy and stability
Warmed probe for superior performance in condensing environments
Shows measurement
trends and 1-year history graphically
Multilingual user interface
Excellent
performance in harsh chemical concentrations
Corrosion resistant IP65 housing
NIST traceable (certificate included) Data
sheets: see links below right
| Relative humidity measurement HMT330 Operating environment
|
Inputs and outputs Analog outputs
Mechanics HMT330 Series Brochure (.pdf, 18 pages, 4MB, opens in new tab) Ordering
options for HMT331 to HMT338 Ordering options for HMT337 (.pdf file, opens new tab or window) Data on Vaisala site (opens new tab or window) |
HMT330
High accuracy industrial series transmitter
Complete unit
Industrial
Humidity and Temperature transmitter. Includes 2m cable as standard ( except for
HMT331 ).
Operating voltage 10 .. 35 VDC/24VAC,
Two analog outputs selectable
from 0 .. 20 mA, 4 .. 20 mA, 0 .. 1v, 0 .. 5v, 0 .. 10v.
Excludes Graphical
Display. Refer to order form for all available options. $1234+GST
4/09
HMT331 Transmitter for Wall Mounting. $1234+GST
4/09
Temperature range
-40°C to +60°C
HMT333 Transmitter with Compact Probe. $1447
Temperature
range -40°C to +80°C
HMT333H Transmitter with Compact Probe. $1702
Temperature range -40°C to +120°C
HMT334 Transmitter
with Pressure Tight Probe. $2500
Temperature range -70°C
to +180°C
HMT335 Transmitter with High Temperature Probe. $1968
Temperature
range -70°C to +180°C
HMT337 Transmitter with Small Vapour-tight Probe.
$1840
Temperature range -70°C to +180°C
HMT337W
Transmitter with Small Vapour-tight, Warmed Probe. $2766
Temperature
range -70°C to +180°C
HMT338 Transmitter with Probe for Pipeline Installations.
Temperature range -70°C to +180°C
$2202
Options
HMT300CP2 Extra variables (Td/Tf,
a, x, Tw, ppm, pw, pws, h, dT) $596+GST 4/09
HMT330LD
Graphic LCD with backlight $394
DCDC-1SUB Galvanic
isolation for outputs $85
POWER-1SUB Power supply module $255
215996
Power
supply module with AUS power cord $277
RELAY-1SUB Relay output $234
RS485-1SUB RS-485 serial interface $192
AOUT-1SUB 3rd
analog output $192
212142 8-pole
connector with 5 m cable $64
212416 8-pole
connector equipped with screw terminals $64
25041HM Chemical
purge (with HUMICAP180C) $43
LOGGER-1SUB Data logger module $489
ETHERNET2
Ethernet(LAN) interface + 2 m cable (RJ45) $290
WLANATENNA1 WLAN wireless
interface + antenna $540
| Optional Sensor Heads and Cable Lengths HMP303PZ5-2 5 m Cable for HMT333 $170 HMP303PZ10-2 10 m Cable for HMT333 $372 HMP303PHZ5-2 5 m Cable for HMT333H $532 HMP303PHZ10-2 10 m Cable for HMT333H $777 HMP304PZ5-2 5 m Cable for HMT334 $192 HMP304PZ10-2 10 m Cable for HMT334 $447 HMP305PZ5-2 5 m Cable for HMT335 $192 HMP305PZ10-2 10 m Cable for HMT335 $447 HMP307PZ5-2 5 m Cable for HMT337 $192 HMP307PZ10-2 10 m Cable for HMT337 $447 HMP308PZ5L178-2 5 m Cable for HMT338 $192 HMP308PZ10L178-2 10 m Cable for HMT338 $447 HMP308PZ2L400-2 400 mm probe with 2 m cable for HMT338 $138 HMP308PZ5L400-2 400 mm probe with 5 m cable for HMT338 $340 HMP308PZ10L400-2 400 mm probe with 10 m cable for HMT338 $585 213886 Additional T probe with 2 m cable for HMT337W with warmed probe *) $170 213888 Additional T probe with 5 m cable for HMT337W with warmed probe *) $213 213889 Additional T probe with10 m cable for HMT337W with warmed probe *) $330 *) Note! When Ordering additional T probe (213886, 213888 or 213889) calculated variables are automatically included free of charge for the HMT337W | HMT330
accessories 215003 Duct installation kit
for temperature probe $117 |
The
Vaisala Meteorological Installation Kit HMT330MIK enables the Vaisala HUMICAP®
Humidity and
Temperature Transmitter HMT337 to be installed outdoors to obtain
reliable measurements for meteorological purposes.
For outdoor humidity
and temperature measurements
Can be ordered in a variety of configurations
Used together with HMT337 transmitter or PTU307
Vaisala SPH
10/20 Static Pressure Head eliminates effectively pressure variations in the barometer
caused by wind
HMT337 / PTU307 Features
Warmed probe provides true humidity readings in condensing conditions
Humidity measurement expressed as relative humidity and/or dewpoint temperature
Easy feld calibration with the HM70 hand-held meter
Data sheets on HMT330MIK Meteorological Installation Kit (.pdf, opens in new tab)
Order Form showing options, for HMT330MIK (.pdf, opens in new tab)
HMT330MIK Meteorological
Installation Kit
215218 Support bar & transmitter mounting plate &
shield for heated Td probe $936+GST 4/09
215219 Support
bar with DTR502 shield for T probe $872
215220 Support bar with DTR13 shield
for T probe $1468
215221 Support bar with DTR502 shield for non-warmed RH
or Td probe $872
215220 Support bar with DTR13 shield for non-warmed RH or
Td probe $1468
10387 Pole mounting plate for support bar/bars $160
215279
Transmitter mounting plate for support bar assembly $138
215280 Transmitter
mounting plate for pole assembly $138
SPH10 Static Pressure Head $532
SPH10
& SPH20 (heated) Static Pressure Heads
Vaisala's static pressure heads
are designed to minimize the errors in barometric pressure measurement caused
by variations in wind speed and direction.
CALCULATION
OPTIONS FOR HMP 230 SERIES
HMP230CP2 Basic dew point transmitter for RH +
T + Td
HMP230CP3 Extended Basic transmitter for RH + T + a +
Tw + x
HMP230CP4 Extended dew point trans. for RH + T + Td + a + Tw
+ x + h
HMP230CP6 Extended Basic transmitter for RH + T + h
HMP231
Humidity & Temperature transmitter for Wall Mounting, -40 to 60°C.
Probe is attached to box. (Humidity is temperature compensated.)
Microprocessor based, two user scalable analogue output signals (scalable ranges),
0...20 mA, 4...20 mA, 0...1 V, 0...5 V, 0...10
V
RS232C serial output, req 20...28VDC/AC. Various versions:
HMP231 Basic transmitter for RH+T - superceded by HMT330 above
The following have probe on end of cable
HMP233L
Humidity & Temperature Transmitter for Confined Spaces (smaller head,
12mm dia), operation -40 to 80°C,
RH output is temp. compensated,
two outputs scalable within 0..20mA or 0..10V,
serial RS232C interface, 2m
cable. Req 20..28VDC/VAC
HMP233LA Basic Transmitter RH+T
Optional 5m or 10m cables
HMP233H for Confined Spaces & operation to 120°C
HMP233H Basic Transmitter RH+T
Optional 5m or 10m cables
HMP230 Series is superceded by HMT330 above
HMP234 for Pressurized Spaces, 0 to 100bar (10MPa)
HMP234 Basic Transmitter RH+T
Optional 5m or 10m cables
HMP 235
Humidity and Temperature Transmitter for High Temperatures up to 180°C,
RH output signal temp. compensated, two output signals scaleable within 0..20mA
or 0..10V,
serial interface RS232C, power supply 20..28VDC/AC, 2m cable for
sensor head
HMP235 Basic Transmitter RH+T
Optional 5m or 10m cables
HMP230 Series is superceded by HMT330 above
HMP237 Humidity and Temperature Transmitter with Small Probe and High Temperatures up to 180°C
HMP237 Basic Transmitter RH+T
Optional 5m or 10m cables
HMP238
Humidity and Temperature Transmitter for Pressurised
Pipelines (0 to 4MPa)
HMP230 Series is superceded by HMT330 above
Regaining
Regaining option for the HMP230 series transmitter.
Enables programmable,
periodic heating of the Humicap sensor to remove build-up of contaminants
HMP230 LD Display / Keyboard unit (not available separately)
| HMP233PZ5 5m
Extended cables for HMP233, 80°C unit HMP233PZH5
5m Extended cables for HMP233, 120°C unit
HMP234PZ5 5m Extended cables for HMP234 5
HMP235PZ5 5m Extended cables for HMP234 HMP238PZ5
5m Extended cables for HMP234 | HMP230PW
Internal 115/230VAC power supply (Not for HMP231)
HMP230CL Current Loop module
HMP233FA Duct Install'n kit for HMP233 80°C unit HMP230PP 240VAC to 24VAC plug pack DMP 240ALSP Alarm Relay for HMP230 / DMP 240 |
HMT360 Series Intrinsically Safe Humidity Transmitters
Transmitters for use in potentially explosive atmospheres. The whole transmitter
can be installed directly into an explosive area, even into areas classified as
having a constant risk of explosion. See above.
HMP140A Series
Humidity Transmitters -
superceded by HMT100 above
Versatile transmitters for humid spaces, outdoor installations
as well as process control and equipment performance monitoring.
IP65 protected.
(without salts) for Vaisala probes.
Humidity
Calibrator, operation is based on the use of salt solutions.
Consists of
two salt chambers, thermometer and instructions.
Salts and Ion exchanged
water need to be ordered separately.
Refer to order form for all available
options.
Two salt chambers with 4 holes, one for the thermometer,
and
three different sized holes for various Vaisala sensors: 12mm, 13.5mm, 18.5mm,
Ion exchange water, 60ml
covers, base plate & mercury thermometer
acc ±0.3°C $670+GST 4/09
Order salts
separately:
# Recommended for normal calibration (0% to 75% RH)
* Rec. salts for high humidity calibration (75% to 100% RH)
#* LiCl for 11.3% RH;
# NaCl for
75.5% RH;
MgCl2
for 33% RH;
*K2SO4 for 97.6% RH;
Mg(NO3)2
for 54% RH
Data sheet on HMK15 (.pdf, opesn in new tab) Order form showing options (.pdf, opens in new tab) Data on HMK15 (Vaisala site)
19766HM
additional salt chamber for HMK15 $202+GST 4/09
19729HM LiCl salt ( 11% RH ) with certificate $53
19730HM MgCl salt ( 33
%RH ) with certificate $53
19731HM NaCl salt ( 75% RH ) with certificate
$53
19732HM K2SO4 salt ( 97% RH ) with certificate $53
19767HM ion exchanged
water, 60 ml $21
HM27032 Transfer bag for HMK15 $192
211302SP Calibration
Adapter for 12mm probes. Eg. HMP76 $21
Spares for HMK15
19728HM
Thermometer for HMK15, mercury, ±0.3°C (supplied with HMK 15)
$266
25130HM Thermometer for HMK15, red capillary liquid, ±1°C
$266
19746HM Set of plugs for HMK15 salt chamber (4 plugs to block unused holes
in calibrator) $11 4/09
Calibration Service
CAL-RH/T Two
point Humidity calibration against saturated salt solutions;
One point calibration of temperature (for products with
temp sensor). No calibration certificate provided. $175
CAL-CERT Additional
charge for a calibration certificate. For recalibration, shows before and after
readings
Order this item when a calibration certificate is required with a
new product. $70
Order both CAL-RH/T and CAL-CERT if a certificate is required for existing product calibration.
DMP246
Dewpoint Transmitter for high temperatures, up to 350°C.
Dewpoint temperature measurement range from +10°C to 100°C.
Two output
signals scaleable within 0..20mA, 4 to 20mA, 0 to 1V, 0 to 5V, or 0 to 10V.
RS232C Serial Interface, (includes DMP246CS cooling set) Superceded
DMP248 Dewpoint Transmitter
for high humidity applics.
Superceded by DMT340 below
Operating range: -40° to +80°C, Dewpoint range:
-40° to +60°C.
Two scalable output signals 0..20mA, 4..20mA, 0..1V,
0..5V, 0..10V. RS232C interface, 2m cable. Req 20..28VDC/VAC
Designed for industrial low dewpoint measurements below 10% (RH). Ideal for dry air monitoring and plastic dryers.
Successor of the DMP248 dewpoint transmitter
Four different probe
types designed to meet various installation requirements
Measures dewpoints
from -60 °C to +80 °C (-76...+176 °F) with the accuracy of ±2
°C (±3.6 °F)
Vaisala DRYCAP® Sensor provides accurate,
reliable measurement with excellent long-term stability and fast response
Withstands condensation
Unique auto-calibration feature
Optional alarm
relays, local display and mains power supply module
Compatible with Vaisala
DRYCAP® Hand-Held Dewpoint Meter DM70
NIST traceable (certificate included)
Individually configured for user's needs
DMT340
Series Brochure (.pdf, opens in new tab)
Order Form for DM342_344_347_348 showing options (.pdf, opens in new tab) DMT340 Data (Vaisala site)
Dewpoint measurement
Measurement range:
-70 ... +80 °C (-94 ... +176 °F) Td
Accuracy at -60...+80 °C (-76
+176
°F): ±2 °C (±3.6 °F) Td
Sensor: Vaisala DRYCAP®
180M
Temperature measurement
Measurement range: 0 ... 80 °C
(+32 ... +176 °F)
Accuracy at +20 °C (+68 °F): ±0.2 °C
Sensor: Pt 100 IEC 751 1/3 class B
Inputs and outputs
Operating
voltage: 10 ... 35 VDC, 24 VAC, 100 ... 240 VAC 50/60 Hz
Outputs: (2 standard,
3rd optional)
current output: 0 ... 20 mA, 4 ... 20
mA
voltage output: 0 ... 1 V, 0 ... 5 V, 0 ... 10
V
Digital outputs: RS-232, RS-485 (optional)
Relay outputs: 0.5 A, 250
VAC, SPDT (optional)
Display: LCD with backlight, graphic trend display of
any parameter
DMT340 Industrial Dewpoint transmitter: Includes 2m
cable as standard.
Operating voltage 10 .. 35VDC/24VAC, Two analog outputs
selectable from 0 .. 20mA, 4 .. 20mA, 0 .. 1V, 0 .. 5V, 0 .. 10V.
Includes
Td, PPM and x variables as standard. Excludes Graphical Display.
Refer to
order form for all available options.
DMT342 With Small Size Flanged Probe
for use with sampling cell $3330+GST 4/09
DMT344 For Pressurized Processes $3607
DMT347 With Small Pressure-tight Probe $3128
DMT348
For Pressurized Pipelines $3468
HMP302PZ5-2 5 m cable
for DMT342 $192+GST 4/09
HMP302PZ10-2 10 m cable for DMT342 $447
HMP304PZ5-2 5 m cable
for DMT344 $192
HMP304PZ10-2 10 m cable
for DMT344 $447
HMP307PZ5-2 5 m cable for DMT347 $192
HMP307PZ10-2 10 m cable for DMT347 $447
HMP308PZ5L178-2
5 m cable for DMT348 $192
HMP308PZ10L178-2 10 m cable for DMT348 $447
HMP308PZ2L400-2 400 mm probe with 2 m cable for DMT348 $138
HMP308PZ5L400-2 400 mm probe with 5 m cable for DMT348 $340
HMP308PZ10L400-2 400 mm probe with 10 m cable for DMT348 $585
DMT340
Options and Accessories
HMT330LD Graphic
Display with keypad $394+GST
4/09
DCDC-1SUB Galvanic isolation for outputs
$85
POWER-1SUB Power Supply Module $255
215996 Power
Supply Module with AUS-power cord $277
LOGGER-1SUB Data logger
module $489
ETHERNET2
Ethernet(LAN) interface + 2 m
cable (RJ45) $309
WLANATENNA1 WLAN wireless interface + antenna $575
219916 MI70LINK software for Windows®
+ USB-RJ45 Serial Connection $160
RELAY-1 Relay module $234
RS485-1 Isolated RS485 Module $192
AOUT-1 Analog
output module $192
212142 Connection
Cable 5m 8 pin M12 Female, Black $64
212416 Connector
8 pin M12 with Screw Terminals $64
215005 RS232
cable for PC with MI70LINK software for Windows $106
19446ZZ Serial
Interface Cable $53
211339 MI70 Connection
Cable with RJ45 Connector $75
Transmitter and Probe mounting options
for DMT340 series
214829 Wall mounting kit $106+GST
4/09
215108 Installation Kit for Pole
or Pipeline $128
215109 Rain Shield with Installation Kit
$170
215094 DIN
Rail Clips with Installation Plate $117
HMP302SC Sampling
Cell for Probe with Flange $149
BALLVALVE-1 Ball Valve ISO1/2 with
Welding Joint $128
DM240FA Installation
Flange ISO1/1 $117
DMT242SC Sampling
Cell with Female Connectors for DMT347 $149
DMT242SC2 Sampling
Cell with Swagelok Connectors for DMT347 $170
THREADSETA Two Fitting
bodies: R 1/2" ISO with leak screw + NPT1/2" $64
SWG12ISO38 Swagelok
for 12mm Probe 3/8" ISO Thread for DMT347 $75
SWG12NPT12 Swagelok
for 12mm Probe 1/2" NPT Thread for DMT347 $75
ISOFITBODASP Fitting
Body Set ISO 1/2 for DMT348 $53
DRW212076SP Fitting
Body ISO 1/2 solid structure, for DMT348 $53
NPTFITBODASP Fitting Body
Set NPT 1/2 for DMT348 $53
Data
on DMT345 and DMT346 (.pdf files, these open in new tabs)
Order
Form for DMT345 showing options (.pdf)
Order
Form for DMT346 showing options (.pdf) Data
on DMT345 & DMT346 (Vaisala site)
DMT345 For accurate
high temperature humidity measurement $3862+GST 4/09
DMT346 With Passive cooling for very hot processes $6629
DMT345 & DMT346 Sensor head optional cable lengths
HMP305PZ5-2
5 m cable for DMT345 $192+GST 4/09
HMP305PZ10-2 10 m cable for DMT345 $447
DMP346PZ5-2 5
m cable for DMT346 $192
DMP346PZ10-2 10 m cable for DMT346 $447
DMT345
& DMT346 Options and Accessories
HMT330LD Graphic Display with
keypad $394+GST 4/09
DCDC-1 Galvanic
isolation for outputs $85
POWER-1 Power Supply Module $255
215996
Power Supply Module with AUS-power cord
$277
RELAY-1 Relay module $234
RS485-1 Isolated
RS485 Module $192
AOUT-1 Analog output module (3rd analog
output) $192
212142 Connection Cable 5m 8 pin M12 Female, Black $64
212416 Connector 8 pin M12 Female with Screw Terminals $64
219916 MI70LINK
software for Windows® + USB-RJ45 Serial Connection $160
214829 Wall Mounting
Kit $106
215108 Installation Kit for Pole or Pipeline $128
215109 Rain
Shield with Installation Kit $170
215094 DIN Rail Clips with Installation
Plate $117
215005 Mi70Link Software with serial line cable $106
214806SP
Male Connector 8 pin M12 with Cable and Adapter $32
211339 Mi70 Connection
Cable with RJ45 Connector $75
217490 Mounting Flange for Cooling set ( spare
part ) $202
Data on DMW19 (Vaisala site)
DMW19 Wall mount HVAC Dewpoint transmitter,
IP33 $809+GST 4/09
Optional
outputs: 0..1V, 0..5V or 4..20mA
Consists of MI70AUS plus one probe from the list below.
Displays Dewpoint
/ Frostpoint temperature, Relative Humidity, ppmv or Process Temperature.
Data sheets on DM70 (.pdf, opens in new tab) Order Form showing options (.pdf, opens in new tab) Data on DM70 (Vaisala site)
MI70AUS Indicator with backlit LCD display.
Displays up to 3 parameters at a time either numerically or
graphically.
Includes data logging and can be used as a field
calibrator for Vaisala transmitters.
Complete with rechargeable battery and AC adapter $1596+GST
4/09
DMP74A Dewpoint probe for MI70. Dewpoint temperature
measurement range from -40 to +60°C. $2713+GST 4/09
DMP74B Dewpoint probe for MI70. Dewpoint temperature measurement range from -60
to +20°C. $3032
Sample Systems and Cells
DSC74 Sample cell
for DMP74 with quick connector & leak screw $160+GST 4/09
DSS70A Portable sampling system $3022
DMT242SC Sampling cell (DRW010773) $149
DMT242SC2 Sampling cell w. Swagelok
connectors (DRW212666) $170
Options for DM70
MI70case Carrying
case for DM70, black ABS $300+GST
4/09
MI70link Windows software
& RS232 cable for MI70 $106
219687 USB
cable for MI70 with MI70Link Windows® software $160
27159ZZ MI70
Connection Cable for DMP248 $75
27160ZZ MI70
Connection Cable for DMT242 $75
211917ZZ MI70
Connection Cable for DMT142 $117
211339 MI70
Connection Cable for DMT340 $75
27168ZZ
MI70 analog output cable $53
Spares for DM70
26755 Rechargeable NiMH
Battery Pack $53+GST 4/09
MI70AUSADAPTER Mains
AC adapter $106
DM70 Hand Held
Dewpoint Meter.
Consists of MI70AUS plus one probe from the list below.
Displays Dewpoint / Frostpoint temperature, Relative Humidity, ppmv or Process
Temperature.
MI70AUS Indicator with backlit LCD display.
Displays
up to 3 parameters at a time either numerically or graphically.
Includes
data logging and can be used as a field calibrator for Vaisala transmitters.
Complete with rechargeable battery and AC adapter
$1596+GST 4/09
DMP74C Dewpoint probe for MI70 to measure SF6 gas. Dewpoint $3767
Sample Systems and Cells
DSC74B Two pressure sampling cell $309+GST 4/09
DSC74C Two pressure sampling cell with coil $575
DMCOIL Cooling/venting
coil $340
Options for DM70
MI70case Carrying
case for DM70, black ABS $298+GST 4/09
MI70link
Windows software & cable for MI70 $106
219687
USB cable for MI70 with MI70Link Windows®
software $160
211917ZZ MI70 Connection Cable for DMT142 $117
27168ZZ
MI70 analog output cable $53
26755 Rechargeable
NiMH Battery Pack $53
MI70AUSADAPTER Mains AC adapter $106
** The DMT142/152 Miniature Dewpoint Transmitter is available for fixed SF6
installations
Data on DMT142 (Vaisala site)
DMT142OUTA Dewpoint transmitter 0..1V
$798+GST 4/09
DMT142OUTB Dewpoint transmitter
0..5V $798
DMT142OUTC Dewpoint transmitter 4..20mA $798
DMT242SC
Sampling cell (DRW010773) $149
DMT242SC2 Sampling cell w. Swagelok connectors (DRW212666)
$170
DSC74 Sampling
cell w. quick connector&leak screw (DSC74A) $160
211598 DMT142
2m M8 output cable $21
HMP50Z032 0.3 m (1.0 ft) shielded
output cable, M8 threaded connector $16
HMP50Z300 3 m (9.8
ft) shielded output cable, M8 threaded connector $32
HMP50Z500 5
m (16.4 ft) shielded output cable, M8 threaded connector $43
HMP50Z1000 10
m (32.8 ft) shielded output cable, M8 threaded connector $85
Spare Parts
DMT142RS Serial Interface Cable RS232 $106+GST 4/09
211917ZZ MI70 Connection Cable $117
DRW010335 Sintered filter $53
Data on DMT152 (Vaisala site)
DMT152 Low Dewpoint Transmitter (-80..-30°C).
Non calibrated range
extends to -100 to +20°C. SF6 model available. $1724+GST
4/09
211589 Connection cable, snap on. 2m,
M8 connector $21+GST 4/09
HMP50Z032 0.3 m shielded output cable, M8 threaded connector $16
HMP50Z300
3 m shielded output cable, M8 threaded connector $21
HMP50Z500 5 m shielded
output cable, M8 threaded connector $42
HMP50Z1000 10 m shielded output cable,
M8 threaded connector $85
DMT242SC Sampling cell $160
DMT242SC2 Sampling
cell w. Swagelok connectors $170
DSC74 Sampling cell w. quick connector&leak
screw $160
DSC74B Two pressure sampling cell $309
DSC74C Two pressure
sampling cell with coil $575
218964 Plastic case $64
Spare Parts
219690 USB Serial Interface Cable $223+GST 4/09
219980 MI70 Connection Cable $170
220957SP Stainless steel mesh filter (8
µm) $64
221524SP Sealing ring set (Cu) ISO G1/2" , 3 pcs $21
221563SP Sealing ring set (Cu), 3 pcs for DMT152 UNF 3/4"-16 version $21
POWER-1 Power supply module, 100..240VAC/24VDC, IP30 $255
Data on DMT242 (Vaisala site)
DMT242A Dewpoint Transmitter.
Measurement range -80 ... + 20 Deg. C. $1649
DMT242B Dewpoint
Transmitter. Measurement range -60 ... + 60 Deg. C. $1649
HM47280SP Sintered
filter $64+GST 4/09
DMT242RS Serial line cable $117
DMT242SC Sample cell $149
DMT242SC2 Sampling cell w. Swagelok connectors $170
DSC74 Sampling
cell w. quick connector & leak screw $160
HMP260
EX Intrinsically Safe Humidity Transmitter
- No longer available -
HMP228 replaced by MMT330 series
HMP228 Moisture
and Temperature Transmitter for Oil
Fast, reliable and accurate on-line detection
system for water in oil. Measures water activity, ppm calculation available for
transformer oil.
MMT318 Moisture and Temperature
Transmitter for Oil
Module-type transmitter for lubrication, hydraulic and
transformer oils. Ideal for OEM system integrations.
Industrial Moisture in Oil transmitters. Include
2m cable as standard.
Operating voltage 10..35VDC/24VAC,
Two analog
outputs selectable from 0 .. 20mA, 4 .. 20mA, 0 .. 1V, 0 .. 5V, 0 ..
10V.
Excludes Graphical Display. Refer to order form for all available options.
Data on MMT330 (.pdf, opens in new tab)
MMT332 with Small Flanged Probe for High Pressure Processes $3096+GST 4/09
MMT337 with Small Pressure Tight Probe $2447
MMT338 with Adjustable Probe for Pressurized Pipelines $2820
Optional
sensor heads and cable lengths
HMP302PZ5-2 5 m cable for MMT332
HMP302PZ10-2 10 m cable for MMT332
HMP307PZ5-2 5 m cable for MMT337
HMP307PZ10-2 10 m cable for MMT337
HMP308PZ5L178-2 5 m cable for MMT338
HMP308PZ10L178-2 10 m cable for MMT338
HMP308PZ2L400-2 400 mm probe with
2 m cable for MMT338
HMP308PZ5L400-2 400 mm probe with 5 m cable for MMT338
HMP308PZ10L400-2 400 mm probe with 10 m cable for MMT338
| Options | Accessories |
Industrial Moisture in Oil transmitters. Includes
2m cable as standard.
Operating voltage 10 .. 35VDC,
Two analog outputs
selectable from 0 .. 20mA or 4 .. 20mA. Refer to order form for all available
options.
MMT317 with Small pressure-tight probe $2224+GST
4/09
MMT318 with Adjustable Probe for Pressurized
Pipelines $2586
| Optional sensor heads and cable lengths HMP307PZ5-2 5 m cable for MMT317 HMP307PZ10-2 10 m cable for MMT317 HMP308PZ5L178-2 5 m cable for MMT318 HMP308PZ10L178-2 10 m cable for MMT318 HMP308PZ2L400-2 400 mm probe with 2 m cable for MMT318 HMP308PZ5L400-2 400 mm probe with 5 m cable for MMT318 HMP308PZ10L400-2 400 mm probe with 10 m cable for MMT318 | Other options for MMT310 series:
|
MM70 Hand-held Moisture Meter
for Oil
Designed for fast and easy on-site checking and transmitter calibrations.
Graphical display, data logging and data transfer to PC.
Consists of MI70AUS plus one probe from the list below.
MI70AUS Indicator with backlit LCD display.
Displays up
to 3 parameters at a time either numerically or graphically.
Includes data
logging and can be used as a field calibrator for Vaisala transmitters.
Complete
with rechargeable battery and AC adapter $1596+GST
4/09
MMP78 Moisture in Oil probe for MI70. $3384
Options for MM70
HMT300CP6 Average ppm calculation (for transformer
oil)
HMP228BVS Ball valve set (incl. fitting body and blanking plug)
210662
Connecting adapter to NPT 1/2"
27159ZZ MI70 Connection cable to HMP230
series / HMP228
DRW216050 MI70 Connection cable to MMT318
213107 10 m
extension cable for the probe
MI70CASE2 Carrying case for MI70 + HMP75/76
(ordered separately)
219687 USB cable for MI70 with MI70Link Windows®
software
Industrial
Moisture in Oil transmitter. Operating voltage 14 .. 28VDC,
Two analog outputs
selectable from 0 .. 20mA, 4 .. 20mA, 0..1V, 0..5V or 0..10VDC.
Refer to
order form for all available options.
MMT162-Plastic OEM
moisture and temperature transmitter for oil (plastic housing) $1351+GST 4/09
MMT162-Metal-ISO OEM moisture and temperature transmitter for oil (metal
housing) $1468
MMT162-Metal-NPT OEM moisture and temperature transmitter
for oil (metal housing) $1468
Options for MMT162:
HMT300CP6
Average ppm conversion (for Mineral Transformer Oil only)
MMT162CP5 Specific
ppm calculation (for transformer oil)
OILMODELLING Laboratory work for specific
ppm calculation (one time cost)
211589 Connection cable, snap on. 2m, M8 connector
HMP50Z032 0.3 m shielded output cable, M8 threaded connector
HMP50Z300 3 m
shielded output cable, M8 threaded connector
HMP50Z500 5 m shielded output
cable, M8 threaded connector
HMP50Z1000 10 m shielded output cable, M8 threaded
connector
221739 Connection cable, 3 m, Shielded, connector 90° angle
221740 Connection cable, 5 m, Shielded, connector 90° angle
MP300LEDCBL
Connection cable, 3m, M8 threaded, Ch1 signal + Ch2 LED
219690 USB Serial
Interface Cable
219980 Connection cable for MM70
DMT242SC Sampling cell
DMT242SC2 Sampling cell w. Swagelok connectors
POWER-1 Power supply module,
100..240VAC/24VDC, IP30
218773 ISO 1/2" plug
222507 NPT1/2"
plug
221524SP Sealing ring set (Cu) ISO G1/2" , 3 pcs
221563SP Sealing
ring set (Cu), 3 pcs for DMT152 UNF 3/4"-16 version
221494SP Stainless
steel filter
221493SP Stainless steel filter for high flow
Prices (Australian dollars) do not include GST and may change without notice.
Lower
Cost Humidity Sensors: HMW 40 & 50
HUMITTER 50 Integrated Humidity Transmitter, used
in items below.
Acc at 20°C: 5% for 2 years.
Uses
INTERCAP TM rel. humidity sensor, linear
0-1VDC output for RH, req 7..28VDC
Wiring:
"3-wire" means 3 wires for one sensor: Ground, Power and Vout.
For humidity and temperature sensors, an extra wire is required for the extra
voltage output.
"2-wire" means 2 wires for current loop output.
Humidity and temperature sensors require
two "two-wires", i.e.
4 wires total.
In the diagram to the right, the circles with V and mA are meters or measuring devices for the voltage or current.
HMW60
HMW60U Humidity only transmitter,
2-wire, wall mount,
with output: 4..20mA.
Humidity ±2%. One point electronic
humidity calibration. DC supply must be at least 10V above highest Vout,
<35VDC.
Isolated AC supply may be used 9..24VAC to 17..24VAC dep on Vout.
$370
HMW60Y Humidity & Temperature,
2-wire, wall mount, 4..20mA
loop powered output, ±2%, -20 to +60°C
One point electronic
humidity calibration. DC supply must be at least 10V above highest Vout,
<35VDC. $520
HMW60T Temperature,
2-wire, wall mount, 4..20mA
loop powered output,
One point electronic humidity calibration. DC
supply must be at least 10V above highest Vout, <35VDC. $320
Data on HMD & HMW 60 & 70 Humidity & Temp. Transmitters (Vaisala site)
HMW70U Humidity
only transmitter 3-wire, wall
mount, with jumper selectable outputs: 0..1V, 0..5V, 0..10V;
with current module also 0..20mA. Humidity ±2%. One point electronic
humidity calibration.
DC supply must be at least 10V above highest Vout,
<35VDC.
Isolated AC supply may be used 9..24VAC to 17..24VAC dep on Vout.
$390
HMW70Y
Humidity & Temperature transmitter, 3-wire,
wall mount, -20 to
+60°C, with jumper selectable outputs: 0..1V, 0..5V, 0..10V;
with opt.
current module also 0..20mA. Humidity ±2%, Temp ±0.5%. One
point electronic humidity calibration.
DC supply must be at least 1V above
highest Vout, <35VDC.
Isolated AC supply may be used 9..24VAC to 17..24VAC
dep on Vout. $550
HMW70T
Temperature only transmitter,
3-wire,
wall mount, with jumper selectable outputs: 0..1V,
0..5V, 0..10V;
with current module also 0..20mA. Temp ±0.5%. DC
supply must be at least 10V above highest Vout, <35VDC.
Isolated AC supply
may be used 9..24VAC to 17..24VAC dep on Vout. $330
With Wall Mount IP65 Enclosure - for harsh and humid environments
These have interchangeable probes which makes calibration and maintenance simple.
For greenhouses, mushroom sheds, livestock sheds, storage, wash down areas, indoor swimming pools, breweries, wineries, etc
HMW61/71 have been replaced by the HMT100 series
HMW61U
Humidity only transmitter, 2-wire, with
wall mount IP65 rated enclosure, 4..20mA output,
one point electronic
humidity calibration. DC supply must be at least 1V above highest Vout, <35VDC.
$430
HMW61Y Humidity
& Temperature transmitter, 2-wire, with wall mount IP65 rated enclosure,
-20 to +60°C, 4..20mA output,
one point electronic humidity calibration.
DC supply must be at least 1V above highest Vout, <35VDC. $595
HMW71U Humidity only transmitter
3-wire, wall mount IP65 rated enclosure,
with jumper selectable
outputs: 0..1V, 0..5V, 0..10V;
Humidity ±2%. One point electronic
humidity calibration. DC supply must be at least 10V above highest Vout,
<35VDC. $450
HMW71Y Humidity &
Temperature transmitter 3-wire, wall mount IP65 rated enclosure,
-20 to +60°C,
with jumper selectable outputs: 0..1V, 0..5V, 0..10V;
Humidity ±2%. One point electronic humidity calibration. DC
supply must be at least 10V above highest Vout, <35VDC. $630
Data on HMD & HMW 40 & 50 Humidity & Temp. Transmitters (Vaisala site)
HMD40U
Humidity transmitter 2-wire, duct mounting, 4..20mA output, ±3%,
power 10..28VDC.
Uses INTERCAP interchangable rel humidity sensor, no recalibration,
replaceable sensor . $240
HMD40Y Humidity
& Temperature 2-wire, duct mounting, 4..20mA output, -10 to +60°C,
power 10..28VDC.
Uses INTERCAP interchangable rel humidity sensor, and Pt1000
temperature sensor. $410
HMD50U
Humidity transmitter, 3-wire, duct mount, Vout
0-1V or 0-10V.
Uses INTERCAP TM sensor. No recalibration required.
Req 15-35VDC or 12-24VAC, 6mA $250
HMD50Y Humidity &
Temperature, 3-wire, duct mount, -10 to +60°C,
Vout 0-1V or 0-10V.
Uses INTERCAP TM sensor. No recalibration
required.
Req 15-35VDC or 12-24VAC, 6mA $420
Additional
filter is available for use where there may be dust. For the HMD 40:
15724
Metallised plastic grid, 12mm dia $20
Data on HMD & HMW 60 & 70 Humidity & Temp. Transmitters (Vaisala site) Picture: Inside the HMD 60Y
HMD60U
Humidity only transmitter, 2-wire, duct
mount, 4..20mA output signal,
humidity ±2%, one point electronic
humidity calibration.
DC supply must be at least 10V above highest Vout,
<35VDC. $450
HMD60Y
Humidity & Temperature, 2-wire,
duct mount, 4..20mA loop powered output,
humidity ±2%, -40 to +80°C, one point electronic humidity
calibration.
DC supply must be at least 10V above highest Vout, <35VDC.
$660
Additional filter is available for use where
there may be dust. For the HMD 60:
HM46670SP Stainless Steel sintered filter
38µm, 12mm dia $69
13303 Radiation shield for
above: Multi-plate (louvred), 21cm high, 12cm dia, with one probe mounting
gland.
Bracket & U-bolt for mounting on vertical pipe 25-50mm dia., for
HMP45A (HMP35A) or HMD60Y $495
HMD
60T Temperature, 2-wire, duct
mount, 4..20mA loop powered output, humidity ±2%,
One point electronic humidity calibration. Membrane filter. DC supply
must be at least 10V above highest Vout, <35VDC. $390
3-wire Voltage and Current Ouput
HMD70U
Humidity only transmitter, 3-wire,
duct mount, with jumper selectable
outputs: 0..1V, 0..5V, 0..10V;
with current module also 0..20mA. Hum.±2%,
Temp ±0.5%. DC supply must be at least 9V above highest Vout, <35VDC.
Isolated AC supply may be used 9..24VAC to 17..24VAC dep on Vout. $480
HMD70Y Humidity
& Temperature transmitter, 3-wire,
duct mount, -40 to
+80°C, with jumper selectable outputs: 0..1V, 0..5V, 0..10V;
with current
module also 0..20mA. Hum.±2%, Temp ±0.5%. DC supply must
be at least 9V above highest Vout, <35VDC.
Isolated AC supply may be used
9..24VAC to 17..24VAC dep on Vout. $690
HMD70T
Temperature only transmitter,
3-wire, duct mount,
with jumper selectable outputs: 0..1V, 0..5V, 0..10V;
with current module
also 0..20mA. Temp ±0.5%. DC supply must be at least 9V above highest
Vout, <35VDC.
Isolated AC supply may be used 9..24VAC to 17..24VAC dep
on Vout. $420
18945 0..20mA Current Module for HMD70Y $60
Data on HMD & HMW 60 & 70 Humidity & Temp. Transmitters (Vaisala site)
See 2009 Vaisala Catalogue page 149-150 for full descriptions 4/09
0195 Brass Sintered
Filter, 133 microns
6221 Plastic grid, 2mm Protection
10159HM Membrane
filter, 0.2 microns
DRW010276SP PPS plastic grid filter, 6.5mm protection
DRW010281SP
PPS plastic grid with steel netting, 15 microns
DRW212987SP Sintered bronze
filter, 40 microns
HM47280SP Sintered stainless steel filter, 38 microns
HM47453SP Stainless Steel filter grid for vacuum, 3.15mm protection
17039HM Membrane filter, 0.2 microns
HM46670SP Sintered stainless steel filter, 38 microns
DRW010522 Plastic grid,
2mm Protection
DRW010525 Membrane filter, 0.2 microns
16452SP Sintered stainless steel filter, 37
microns
16562SP Plastic grid, 2mm Protection
16720HMSP PPS plastic grid
with steel netting, 14 microns
17230HMSP PTFE membrane filter, 3.5 microns
HM46999SP Stainless steel grid filter
6597 Plastic grid, 2.5mm protection
HM46717 Plastic
grid, 2.5mm protection
2787HM Membrane filter, 0.2 microns
16126HM Metallized
membrane filter, 0.5 microns
HM46780 Sintered stainless steel filter, 38 microns, 20mm diameter
HM47329
Probe Cap, 18 mm Diameter, Protective cap for HMW61/71
19858HM Membrane filter
tube set (5 pieces) for HMP42 probe
19867HM Steel grid for the HMP42