High Temperature loggers - Autoclave

When you need to record temperature (or pressure) in a high temperature environment such as an autoclave or oven, you will need a data logger specifically designed for high temperature and high pressure environments. Most regular data loggers cannot withstand more than about 80°C and that too only for short time periods. 

Esis specialises in high temperature data logging, and we have several loggers that can survive 140°C or even up to 260°C for limited times with a suitable thermal shield. There are several options at different price points, detailed below. If you're feeling unsure, please contact us to discuss your needs.

On this page:

ACR Nautilus Loggers & Autoclave logger, to 135°C

Nautilus Loggers - Rugged loggers for high temperature unforgiving environments

Nautilus85 can stand up against harsh environments.
 
Nautilis135Nautilus135 with high temperature capabilities 135°C, make it the ideal logger for more extreme environments.

ACR Nautilus data loggers are single channel, waterproof temperature data loggers with the ability to record temperature in water, food or other liquids. Designed for rugged applications, Nautilus loggers are available in stainless steel or aluminum.
Nautilus loggers can hold over 500 days of data and feature data compression capability.
With extremely durable and robust construction, Nautilus loggers are your choice for temperature monitoring and logging in wet environments.    zwh    

Monitor high temperatures, where conventional data loggers aren't able to survive.
     Nautilus 85 & 135 Brief Specs (.pdf file, opens in new tab)

     Specs common to both Nautilus Loggers (.pdf file, opens in new tab)

Nautilus85 - for harsh environments to 85 ° C

Operating Range: -40°C to 85°C.  Resolution: 0.4°C, Sensor Accuracy: +/-0.2°C. @ 25°C,
Memory Size: 32 KB, Accessories: None
Number of channels: One (ambient temperature)
Sensor Type: Negative Temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25°C  

  • NTL-100  Nautilus85 with Aluminium case     $395+GST   9/15
  • NTL-101  Nautilus85 with Stainless Steel case $460+GST

    Nautilus85 Data (pdf file, opens in new tab) 

Also requires TrendReader Express software and USB Cable IC-102, or Serial interface cable (see below) 

Calibration

  • NautilusFactCalibCert-2P  Nautilus Factory Calibration Certificate 2 Temp points  $120+GST

Nautilus135 Autoclave Logger to 135 ° C

Autoclaves work by allowing steam to enter, then maintaining the pressure at 103 kPa (1.03 bar,15 psi).
This causes the steam to reach 121 °C, and this is maintained for at least 15 minutes.
Modern autoclaves operate at higher temperature and pressures.   Information about Autoclaves (Wikipedia)
Conversion: 1 bar = 100kPa = 14.5psi

Nautilus135 is designed for autoclaves and can also be used in other applications.
Pressure rating:13,800kPa, 13.8 bar, 2000psi   

Operating Range: 10°C to 135°C.  Resolution: +/-0.2°C @ 25°C,  
Sensor Accuracy: +/- 0.5°C @ 77°C,
Memory Size: 32 KB,  Accessories: None,   
No. of Channels: One (Ambient Temperature),    
Sensor Type: Negative temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25C
    Nautilus135 Data (pdf file, opens in new tab)   

  • NTL-102 Nautilus 135 with Aluminium Case:      $522+GST              9/15
  • NTL-103 Nautilus 135 with SS Stainless Steel Case: $595+GST

Also required: TrendReader® 2 Express or TrendReader® 2 (compatible with Windows® XP, Vista, Windows 7 and Windows 8 - 32 bit or 64 bit)  (see below)

TrendReader 2 Software and Cable

  • TR2-USB software package incl. IC-102 USB cable    $295+GST     9/15
  • TR2-Express-USB software package incl. IC-102 USB cable   $255+GST

Cable only

  • IC-102 USB interface cable    $195+GST     9/15

Calibration

  • NautilusFactCalibCert-2P  Nautilus Factory Calibration Certificate 2 Temp points  $120+GST     9/15

Time stamping of Readings in ACR Data Loggers
All ACR loggers have an accurate clock, but not a real time clock. Data is time referenced when the data is downloaded, from the time and date of the computer. The PC being used should have it's clock set accurately (automatic via internet with Windows XP).
Time references can be adjusted with the TrendReader software.

   Various articles about ACR Loggers (Mfr site, opens in new tab)

Nautilus FAQ

Is the Nautilus product waterproof? To what depth and pressure has it been tested?
While we have no official documentation or third party testing, the product easily withstood our own water testing. The Nautilus casing has been tested in 2000 PSI, which is equivalent to the pressure at a depth of 1400 meters of water.

Can I calibrate the Nautilus data logger?
Low, mid and high calibration values can be adjusted using TrendReader 2 (version 2.30 and higher).

What are the Nautilus operating limits?
The operating range for the Nautilus85 is -40 to 85 degrees Celsius.
The operating range for the Nautilus135 is 10 to 135 degrees Celsius.

What should be done to protect the waterproof seal?
The O-Ring should be moistened with silicon grease to maintain the waterproof seal.

What is the battery life of the Nautilus?
The battery of a Nautilus85 is 10 years and for the Nautilus135 it is 3 years.

Is the battery in a Nautilus data logger replaceable?
Yes. However, it can only be replaced in the factory by ACR Systems Inc.

 

Madgetech Autoclave loggers

HiTemp-140 Data Logger
High Temperature,  to 140 °C - short rigid external probe to 260 °C

HiTemp140The HiTemp140 is a rugged, high precision, temperature data logger that is built for use in harsh environments. This stainless steel device is submersible and can withstand temperatures up to 140 °C (284 °F).
With the HiTemp140’s standard calibration, an accuracy of +/-0.1 °C (0.18 °F) can be achieved over a wide temperature range.   ozb

The HiTemp140 can store up to 32,700 readings, and features a rigid external probe capable of measuring extended temperatures, up to 260 °C (500 °F).

Custom probe lengths are available up to 7 inches. The device records date and time stamped readings, and has non-volatile solid state memory.

Using the MadgeTech Software, starting, stopping and downloading the HiTemp140 is simple and easy.

To use, simply place the HiTemp140 in the IFC400 or IFC406 docking station (sold separately). Using
the software, an immediate or delay start can be chosen, as well as the reading rate.
Start the data logger, remove it from the docking station and the device is ready to be deployed.
Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R.
The data can also be automatically exported to Excel® for further calculations
    Data sheet on HiTemp140 (pdf file, opens in new tab)

•     ±0.1 °C (0.18 °F) Accuracy
•     Operates Up To 140 °C (284 °F)
•     Submersible (IP68)
•     NIST traceable
•     User Replaceable Battery
•     Rugged
•     Programmable start time
•     Programmable stop time
•     Engraved Label
•     Probe Lengths Up To 7 inches
•     Battery Life Indicator

HITEMP140-1     High Temperature Data Logger with a 1” probe 

HITEMP140-2/
HITEMP140-2-TD   High Temperature Data Logger with a 2” probe / 2” transitional diameter probe 

HITEMP140-5.25/
HITEMP140-5.25-TD  High Temperature Data Logger with a 5.25” probe / 5.25” transitional diameter probe 

HITEMP140-7         High Temperature Data Logger with a 7” probe 

IFC400     Docking station with USB cable, software and manual 

IFC406     6 Port, Multiplexer docking station with USB cable, software and manual 

ER1425S-HT   Replacement battery for the HiTemp140 
    *NIST     NIST Calibration Certificate 
*To order the product with the NIST certificate add -CERT to the end of the part number (this increases the price).


HiTemp140-TSK  Data Logger
housed in a thermal shield,  -200°C to 250°C

The HiTemp140-TSK is a kit that includes a HiTemp140 data logger housed in a thermal shield. The combined features of the ±0.1°C accuracy of the HiTemp140 and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. This rugged system can be placed in and withstand temperatures from -200°C to 250°C for a limited time, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing.

Using the MadgeTech software, the data logger is fast and easy to setup. Remove the thermal shield and place the HiTemp140 into the IFC400 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. Place the thermal shield around the HiTemp140 and screw it back together. The device is ready to be deployed.

The HiTemp140-TSK can be completely submerged and is built for applications that require extreme temperature monitoring.

The HiTemp140-TSK is available with an extended warranty.
See above for data sheet on the HiTemp140 logger.

 

HiTemp140-FP  Data Logger 
with a long, flexible RTD probe with a narrow diameter, to 260°C

HiTemp140-FPThe HiTemp140-FP is a durable, user friendly high temperature data logger featuring a long, flexible RTD probe with a narrow diameter, making it ideal for use in steam sterilization and lyophilization processes.

Commonly used for mapping, validation and monitoring of high temperature surfaces and environments, this stainless steel data logger is available in two models, the HiTemp140-FP-36 and the HiTemp140-FP-72, which feature either 36 inch or 72 inch flexible probe lengths, respectively. The flexible probe is coated with PFA insulation and can withstand temperatures up to 260 °C with an accuracy of ±0.1 °C.

The HiTemp140-FP probe design is narrow and lightweight making it ideal for placement within small vials, tubing, test tube and other small diameter or delicate applications. Because of the flexible probe, the risks of breakage (both vial and probe) generally associated with stainless steel probe loggers are diminished and the location and placement of the probe is easy to manipulate. The device records and stores up to 32,700 time stamped readings and is equipped with non-volatile solid state memory that will continue recording even if battery becomes discharged.

The HiTemp140-FP can be configured for delayed start and is capable of reading rates as often as four readings per second, up to once every 24 hours.

Compatible with the latest MadgeTech Data Logger Software, starting, stopping, and downloading data is simple and reporting capabilities are abundant. The device connects to a PC with the IFC400 interface or the IFC406 docking station (sold separately). Downloaded data can be viewed in graphical, tabular, and summary data form in the MadgeTech software, and all data can be exported to Excel® for further analysis and calculations.
    Dimensioned diagram of HiTemp140-FP (pdf file, opens in new tab)

    Data sheet for HiTemp140-FP and HiTemp140-FP-TSK with Thermal Shield (pdf file, opens in new tab)

HiTemp140-FP-36    High Temperature Data Logger with a 36 inch Flexible probe.
HiTemp140-FP-72    High Temperature Data Logger with a 72 inch Flexible probe.
HiTemp140-FP-TSK  HiTemp140-FP data logger and thermal shield with either a 36 inch or 72 inch flexible probe (Flush or Vented).
HiTemp140-TS         Thermal Shield for the HiTemp140-FP data logger (Flush or Vented).
IFC400           Docking station with USB cable, software and manual.
IFC406           6 Port, Multiplexer docking station with USB cable, software and manual.
ER1425S-HT   Replacement battery for the HiTemp140-FP.
    *NIST NIST Calibration Certificate.
*To order the product with the NIST certificate add -CERT to the end of the part number (this increases the price).
 

HiTemp140-FR  Data Logger, and Hitemp140-FR-TSK with Thermal Shield
fast response, body to 140°C,  probe -200 °C to +260 °C,  recording up to 4Hz

HiTemp140-FRThe HiTemp140-FR is a high temperature data logger with an ultra-fast response time, to record temperature during rapidly changing thermal processes. This high temperature data logger features a 2 in x 0.0625 in diameter probe and is capable of recording up to 4Hz, which is 5 times faster than other data loggers in this series. This allows the temperature sensor to quickly adapt and accurately record temperature variations in changing environments. Applications include oven profiling, steam sterilization, chamber mapping, seafood processing, flash freezing and more.

MadgeTech’s entire HiTemp140 data logger series is designed with food grade stainless steel. The device can be placed in environments up to 140 °C and the probe is capable of measuring from -200 °C to +260 °C (-328 °F to +500 °F).

The HiTemp140-FR is also available with an optional thermal shield enclosure to extend the operating range of the data logger to -200 °C to +250 °C (-328 °F to +482 °F). The HiTemp140-FR-TSK (Thermal Shield Kit) comes with either a vented or flush top enclosure to accommodate a multitude of applications.

The Trigger Settings feature of the HiTemp140-FR allows users to configure high and low temperature thresholds that when met or exceeded, will automatically start or stop recording data to memory. This data logger is capable of storing up to 32,700 date and time stamped readings and features a nonvolatile solid state memory which retains data even if the battery becomes discharged.

Compatible with the latest MadgeTech Data Logger Software, starting, stopping, and downloading data is simple and reporting capabilities are abundant. The device connects to a PC with the IFC400 interface or the IFC406 docking station (sold separately). Downloaded data can be viewed in graphical, tabular, and summary data form in the MadgeTech software, and all data can be exported to Excel® for further analysis and calculations.
    Data sheet on HiTemp140-FR and HiTemp140-FR-TSK  (pdf file, opens in new tab)

HiTemp140-FR High Temperature Data Logger with a 2 inch Fast Response Probe.
Hitemp140-FR-TSK HiTemp140-FR data logger and thermal shield (Flush or Vented).
HiTemp140-TS Thermal Shield for the HiTemp140-FR data logger (Flush or Vented).
IFC400 Docking station with USB cable, software and manual.
IFC406 6 Port, Multiplexer docking station with USB cable, software and manual.
ER1425S-HT Replacement battery for the HiTemp140-FR.
     *NIST NIST Calibration Certificate.
*To order the product with the NIST certificate add -CERT to the end of the part number (this increases the price).
 

HiTemp140-PT  Data Logger,
body to 140°C, with 600mm flexible probe to  260°C

HiTemp140-PTThe HiTemp140-PT is a submersible, temperature data logger that can operate up to 140°C (284°F) and has an accuracy of +/-0.1°C (0.18°F). The device features a 24” flexible stainless steel probe for measuring extended temperatures up to 260°C (500°F). The probe is durable and can be spiraled, bent or angled in any direction, making it easy to log temperatures within bottles, vials or other hard to reach places.

The HiTemp140-PT records date and time stamped readings, and has non-volatile solid state memory that will retain data even if the battery becomes discharged.

Using the MadgeTech Software, starting, stopping and downloading the HiTemp140-PT is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations.

Accessories
Docking station IFC400 (sold separately) - Interface cable package for the HiTemp140 Data Logger. Includes MadgeTech Software CD, Software Manual, Quick Start Guide, USB Cable and USB Docking Station.

    Data sheet on HiTemp140-PT (pdf file, opens in new tab)

HITEMP140-PT-1 Extended Range Temperature Data Logger with a 24” Bendable Probe with a 1” probe sheath  
HITEMP140-PT-5 Extended Range Temperature Data Logger with a 24” Bendable Probe with a 5” probe sheath  
IFC400 Docking station with USB cable, software and manual  
IFC406 6 Port, Multiplexer docking station with USB cable, software and manual  
ER1425S-HT Replacement battery for the HiTemp140-PT  
   *NIST NIST Calibration Certificate 
*To order the product with the NIST certificate add -CERT to the end of the part number (this increases the price).
 

HiTemp140-PT-TSK  Data Logger
housed in a thermal shield,  600mm probe can be bent -200°C to 250°C

The HiTemp140-PT-TSK is a kit that includes a HiTemp140-PT data logger housed in a thermal shield. The combined features of the data loggers +/-0.1°C accuracy and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. The built in 24” RTD probe can be bent or spiraled in any direction, making it easy to log temperatures in hard to reach places. This rugged data logger system can be placed in and withstand temperatures from -200°C to 250°C, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing.

Using the MadgeTech software, the data logger is fast and easy to setup. Remove the thermal shield and place the HiTemp140-PT into the IFC400 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Select Start to program the settings and start the data logger. Place the thermal shield around the HiTemp140-PT data logger and screw it back together. The device is ready to be deployed.

The HiTemp140-PT-TSK data logger can be completely submerged and is built for applications that require extreme temperature monitoring.

The HiTemp140-PT-TSK is available with an extended warranty.     link 

    Data on HiTemp140-PT-TSK  (pdf file, opens in new tab)

HITEMP140-PT-1-TSK HiTemp140-PT-1 data logger and vented thermal shield
HITEMP140-PT-1-TSK-FL HiTemp140-PT-1 data logger and flush thermal shield
HITEMP140-PT-5-TSK HiTemp140-PT-5 data logger and vented thermal shield
HITEMP140-PT-5-TSK-FL HiTemp140-PT-5 data logger and flush thermal shield
IFC400 Docking station with USB cable, software and manual
IFC406 6 Port, Multiplexer docking station with USB cable, software and manual
ER1425S-HT Replacement battery for the HiTemp140-PT
     *NIST NIST Calibration Certificate
*To order the product with the NIST certificate add -CERT to the end of the part number (this increases the price).
 

Kits with one logger or six loggers

AVS140-1  Autoclave Validation Data Logging System - incl. 1 temperature logger

The AVS140-1 is a complete system used to perform autoclave validations. The AVS140-1 consists a NIST traceable high temperature data logger, an IFC400 Interface Cable and the MadgeTech 4 Secure Software providing tools to users to assist with FDA 21 CFR Part 11 compliance.

The AVS140-1 kit includes:
(1) HiTemp140 High Temperature Data Loggers with 1 in probe style, with NIST Calibration Certificates
(1) IFC400 Docking station with USB cable
(1) MadgeTech Secure Data Logger Software, complete with IQ/OQ/PQ validation protocols and workbook

(other data logger probe lengths and styles available, call for details)

The HiTemp140 is a rugged, high precision, temperature data logger that is built for use with autoclaves and harsh environments. This stainless steel device is submersible, can withstand temperatures up to 140 °C (284 °F) and has an accuracy of +/-0.1 °C (0.18 °F).

The MadgeTech 4 Secure Software aids customers in compliance with 21 CFR Part 11 requirements. The software ensures standards in which electronic files are considered equivalent to paper records, saving time and effort. MadgeTech 4 Secure Software contains criteria such as electronic signatures, access codes, secure data files, and an audit trail which meet the requirements of 21 CFR Part 11 and help provide data integrity.

Also available, the AVS140-6, a multi-logger autoclave validation system  - incl 6 temp. & pressure loggers.
 

AVS140-6
Autoclave Validation Data Logging System - incl 6 temp. & pressure loggers

The AVS140-6 is a complete system used to perform autoclave validations. The AVS140-6 consists of six NIST traceable high temperature and pressure data loggers, an IFC406 Multiplexer Interface and the MadgeTech 4 Secure Software providing tools to users to assist with FDA 21 CFR Part 11 compliance.

The AVS140-6 kit includes:

(5) HiTemp140   High Temperature Data Loggers with 1 in probe style, all with NIST Calibration Certificates
(1) PR140-NPT  High Temperature and Pressure Data Logger with an NPT port, with NIST Calibration Certificate
(1) IFC406       Multiplexer interface
(1) MadgeTech Secure Data Logger Software, complete with IQ/OQ/PQ validation protocols and workbook

(other data logger probe lengths and styles available, call for details)

The HiTemp140 is a rugged, high precision, temperature data logger that is built for use with autoclaves and harsh environments. This stainless steel device is submersible, can withstand temperatures up to 140 °C (284 °F) and has an accuracy of +/-0.1 °C (0.18 °F).

The PR140 is a pressure data logger designed for use in autoclave validation and mapping. This rugged data logger can withstand temperatures up to 140 °C and is completely submersible (IP68). The PR140 is built with a precision stainless steel pressure gauge. The data logger has an accuracy of ±0.03 Bar (±0.435 PSI), which can be achieved over a wide temperature range, from 20 °C to +140 °C (68 °F to 284 °F). The PR140 can be programmed to take readings as often as once per second (1 Hz), and has non-volatile memory that can store up to 32,700 measurements.

The MadgeTech 4 Secure Software aids customers in compliance with 21 CFR Part 11 requirements. The software ensures standards in which electronic files are considered equivalent to paper records, saving time and effort. MadgeTech 4 Secure Software contains criteria such as electronic signatures, access codes, secure data files, and an audit trail which meet the requirements of 21 CFR Part 11 and help provide data integrity.

Also available, the AVS140-1, a single logger autoclave validation system.
 

IFC200 
Interface Cable

MadgeTech’s IFC200 interface cable communicates between stand alone data loggers and the MadgeTech software. Through this interface, loggers can be started, stopped or downloaded.

The IFC200 has been redesigned, and is now “plug and play”. It can be directly connected to a computer without installing any drivers and is compatible with Windows XP SP3, Windows Vista (32 and 64 bit), and Windows 7 (32 and 64 bit) operating systems. The improved IFC200 can now operate at up to 500 Volts RMS relative to the computer’s earth ground when attached.

The IFC200 is equipped with communication LEDs, that provide a quick indication of the device status. The blue light illuminates when the device is plugged in and successfully recognized by Windows. The red light flashes when data is sent, and the green light flashes when data is received.

MadgeTech Data Logger Software

•     Multiple graph overlay
•     Statistics
•     Digital calibration
•     Zoom in/ zoom out
•     Lethality equations (F0, PU)
•     Mean Kinetic Temperature
•     Full time zone support
•     Data annotation
•     Min./Max./Average lines
•     Data table view
•     Automatic report
               generation
•     Summary view
•     Multilingual

 

 

 

 

 

 

 

 


Obsolete models:

  • HiTemp150  Data Logger with  2” rigid external probe & fast response time - replaced by HiTemp140
  • HiTemp150FP  Data Logger, external probe with 600mm cable - replaced by HiTemp140FP
  • HiTemp150-TSK  Data Logger with thermal shield, to 250°C - replaced by HiTemp150-TSK

 

 

Tecnosoft data loggers for up to 140°C incl. S-Radio Loggers

High temperature data loggers

There are different types of Tecnosoft data loggers for high temperatures, different sizes and shapes, suitable for several applications in the pharmaceutiocal and food field, etc.
There are loggers for up to 100°C and loggers for up to 140°C, for the different needs of pasteurisation and sterilisation processes.    zkez

There are also pressure loggers - PressureDisk.

These data loggers can be used also with the TS Manager system, compatible with the FDA 21 CFR Part 11 regulation.

There are some production processes that can be highly improved with a real time monitoring of temperature.
Cables and complicated installations of equipment usually make these systems not so easy to use and too expensive.

Temperature Loggers for up to 140°C

Autoclave loggers

SterilDisk  Temperature Datalogger for sterilization processes

SterildiskThe SterilDisk, data logger for temperatures up to 140°C,
in a circular housing, 36 mm in diameter and just 18 mm high, making it compact and therefore easy to position, even in the tightest spaces or in more than one device when mapping temperature inside chambers.

The main body is in AISI316L stainless steel, whilst the isolating parts are o-rings: these materials, apart from being able to support very high temperatures without exhibiting deformation, are also food grade.
The data logger, therefore, has numerous applications, from medical or industrial, in sterilisation processes, to the food industry, where it is possible to monitor the actual product and not simply the environment in which it is manufactured.
There are also the versions with external probe: 10, 30 or 50 mm length; the 50 mm has a threaded part to be screwed on different surfaces.
The SterilDisk can be provided with a calibration certificate Accredia (Italian calibration center, NIST equivalent) traceable.

Applications:
    sterilisation and general production processes control;
    food transport monitoring, directly in contact with the product;
    laboratories ovens monitoring.

There are also the PasteurDisk Probe and the SterilCyl Radio wireless data logger, all food grade and available with calibration certificate.

    high accuracy and precision;
    compact and available in two versions: standard and Probe;
    completely food grade and waterproof;
    printed reports can be used for health regulations and ISO compliance;
    F0 and PU (Pasteurisation Units) calculation and possibility to customize parameters;
    can have a calibration certificate.

The basic system is made up by:
    SterilDisk temperature data logger;
    DiskInterface HS Mini or DiskInterface HS;
    SPD software.

The advanced TS Manager system for autoclave validation is made up by:
    SterilDisk temperature data logger;
    DiskInterface HS;
    TS Manager software.

Both software will give information on battery status when logger is connected.

Size:     18x 36mm diameter
Material:     Stainless steel AISI316L(completely Food Grade)
Temperature range:     0 °C to +140 °C (up to 10 bar)
Resolution:     0,01 °C  
Accuracy:     ± 0,1 °C (within calibration range: +25°C ÷ +125°C)  
No acquisitions:     20,200
Acquisition interval:     From 1 every second up
Battery life:     User replaceable
        1,400,000 acquisitions, with acquisition step of 1” @ 25°C;
        battery life might be less if exposed to high and low temperatures
Protection degree:     IP68 
Compliancy:   CE   ROHS - EN12830 - EN285
   Data sheet on SterilDisk (pdf file, opens in new tab)
 

PressureDisk  Temperature and Pressure logger
for autoclaves with validation software

PressureDiskThe PressureDisk is a data logger for temperature and pressure monitoring, in particular in autoclave, since it resists up to 140°C.
It can be provided alone or in a kit made by the TS Manager software, compatible with FDA 21 CFR Part 11 regulations, and one or more temperature loggers (the software can manage all of your devices).
All can log up to 140°C and resist up to 5 bar of pressure and can be used to map the autoclave and check it is working well.
All devices are in food grade material and are submersible, so that they can be used easily also in the food industry.
With the TS Manager system it is possible to validate autoclaves by professional validators.
PressureDisk is rugged, with a user replaceable battery that can work for several sterilisation cycles; the temperature sensor is on a radial probe while the pressure one is inserted in a threaded insert with a ½ Gas that can be screwed on standard receptacles on autoclaves even if its main use is inside autoclaves.
It is provided with an Accredia (Italian NIST equivalent) traceable calibration certificate

Applications
    Validation of autoclaves or other instruments that need verification of pressure control.
    Internal pressure monitoring of food and non-food packaging during sterilisation process.
    Monitoring of sterilisation and pasteurisation processes.
    Ambient temperature and pressure monitoring.

Validation
The TS Manager system is particularly indicated for autoclaves validators, since it allows to manage a Customer database, with the list of each instrument for each Customer. Being FDA 21 CFR Part 11 compatible it can be easily implemented in every monitoring and validation process, being compliant to law and international regulations. For example, it can be used to validate autoclaves in hospitals, in analysis laboratories, in dentists office or among tattooers and piercers.

The System
The validation system is made up by:
    PressureDisk;
    TS Manager software;
    DiskInterface HS.

PressureDisk can be provided also with a free basic software; in this case the items needed are:
    PressureDisk;
    DiskInterface HS;
    HumiPressureDisk basic software (included with the DiskInterface HS).

Size:     Diameter max: 35 mm; height: 55 mm (included threaded insert ½ Gas)
Temperature probe: length 23 mm, diameter 3 mm
Material:     Stainless steel AISI316L, PEEK (completely food grade)
Temperature range:       -40°C to 140°C (calibration range 25°C to 140°C)
Temperature resolution:    0,01°C
Temperature accuracy:   ± 0,1°C (within calibration range 25°C to 140°C) - ask for extra calibration points for extended accuracy
Pressure range:     10 mbar ÷ 5 bar absolute (calibration ange 100 mbar to 4 bar absolute)
Pressure resolution:     2 mbar
Pressure accuracy:     ± 15 mbar (in the calibration range 100 mbar to 4 bar absolute)
Number of acquisitions:   30000 (date, time, temperature, pressure)
Acquisition rate:     From 1 acquisition every second, up
Battery life:     User replaceable
        6.000.000 acquisitions, with acquisition step of 1” @ 25°C;
        battery life might be less if exposed to high and low temperatures
Accessories:     DiskInterface HS
   Data sheet on PressureDisk (pdf file, opens in new tab)
 

SterilCyl  Temperature Datalogger - discontinued

S-Micro L  Autoclave miniature logger, 140°C

The S-Micro L, 25 mm longer than S-Micro Standard, hosts a battery with superior capacity for extended battery life and calibration range.
The data logger, therefore, has numerous applications in the food and pharmaceutical / medical / laboratory industry, where it is possible to monitor the product and not simply the environment in which it is manufactured.
It is used, for example, to control meat and ham cooking and directly inside food packages, jars, tins, cans.

Applications:
    temperature monitoring in autoclaves;
    temperature monitoring directly in contact with the food and liquid;
    temperature monitoring during meat and ham cooking.

Apart from its tiny size there are many other important features of the Micro logger series:
    high accuracy and precision: with an accuracy of ± 0,1°C
    these devices can be employed in any application involving food,
          pharmaceuticals, validation, laboratory and medical field;
    fast response time thanks to the 3 mm diameter probe;
    low battery consumption for an extended battery life;
    very easy to deploy in any type of package.

S-Micro L on fresh filled pastaAdvantages:
    entirely food grade and waterproof;
    printed reports can be used for health regulations and ISO compliance;
    no need to open them for PC communication;
    F0 and PU (Pasteurisation Units) calculation with customizable parameters;
    provided with calibration certificate ACCREDIA traceable;
    can be calibrated on request for low temperatures (-40°C).
    Battery is user replaceable;
    no need to drill any lids, no need to modify your product packaging:
    program the data logger, place it in your product and start your process!

Size:     39mm x 17mm Ø  (probe excluded)
Probe: 20mm, 60mm, 100mm, 125mm x 3mm Ø
Material:     Stainless steel AISI316L + Peek (completely Food Grade)
Temperature range:     0 °C to +100 °C
Resolution:     0.01 °C  
Accuracy:     ± 0.1 °C (within calibration range: +25°C to +100°C)  
No acquisitions:     20,200
Acquisition interval:     Programmable from 1 every second upwards
Battery life:     User replaceable
     10.000.000 acquisitions, with acquisition step of 1”;
     battery life might be less if exposed to high and low temperatures
Protection degree:     IP68  
Compliancy:   CE   RoHS     - EN12830 - EN285
    Data sheet on S Micro and P Micro (Standard, L, and XL)  (pdf file, opens in new tab)
 

S-Radio  Temperature Datalogger - up to 140°C
for sterilization processes, food cooking, cans and food packages control

S-RadioThe S-Radio is the wireless data logger for high temperatures (up to 140°C).
It is made up by a cylindrical body made of PEEK, a plastic material highly resistant and food compatible; metallic parts are in AISI316L stainless steel.
The main body diameter is 30 mm, the length 76 mm..
It is available with a 3 mm diameter probe with choice of lengths,  the probe is ideal for cans, food packages and jars.
The datalogger, therefore, has numerous applications in the food industry,
where it is possible to monitor the actual product and not simply the environment in which it is manufactured. It is used, for example, to control meat and ham cooking, food packages, cans.
The radio transmission allows to watch on the PC monitor the temperature and the F0/PU curves in real time, and set also threshold alarms.

Applications:
    real time temperature monitoring in autoclaves for sterilisation processes;
    real time temperature monitoring in pasteurization tunnels;
    real time temperature monitoring directly in contact with the food and liquid;
    real time temperature monitoring during meat and ham cooking.

Probes available:
        20, 60, 100, 125 mm length X 3 mm diameter;
        on demand length (21-1000 mm) X 3 mm diameter;
        100 mm length X 5 mm diameter;
        flexible probe with teflon cable, anti-break system in the connectors;
        metal bendable probe.
S-Radio probesThere is also the P-Radio, for pasteurisation processes, food grade and available with calibration certificate.
The non radio loggers, for the same applications, are the S-Micro XL and the SterilDisk.
    High accuracy and precision, food grade, probes of different size;
    printed reports can be used for health regulations and ISO compliance;
    data received with radio transmission, no installation required;
    F0 and PU (Pasteurisation units) real time calculation and possibility to customize parameters;
    no need to open them for PC communication;
    no need to open them for PC communication;
    an Accredia (NIST equivalent) calibration certificate is provided.

The system is made up by:
    S-Radio temperature datalogger;
    DiskInterface HS;
    SPD software;
    USB Radio Receiver for wireless communication.

This datalogger can be used with the Fastening System for probes to be applied on cans, jars, lids for process monitoring.
For this logger the flexible probe, in teflon, the bendable probe and the spoon simulator are available.

Size:     76 x 30 diameter (mm)
Probes: 20mm, 60mm, 100mm, 125mm x 3mm diameter, on demand x 3mm diameter, 100mm x 5mm diameter,
   flexible probe, bendable probe
Material:     PEEK and stainless steel AISI316L (completely Food Grade)
Temperature range:     0 °C ÷ +140 °C
Resolution:     0.01 °C  
Accuracy:     ± 0.2 °C (within calibration range: +25°C to +125°C)  
No. acquisitions:     120,000  
Acquisition interval:     From 1 every second, up
Battery life     User replaceable
     3,800,000 acquisitions, with acquisition step of 1”;
     battery life might be less if exposed to high and low temperatures
Protection degree:     IP68  
Compliancy:  CE  RoHS   - EN12830 - EN285

USB Radio Receiver Radio:     433,92 MHz
    Data sheet on S Radio, etc (pdf file, opens in new tab)

Process Monitor is software for P-Radio and S-Radio loggers only, for food producers, to monitor simultaneously more than one autoclave.

USB Radio Receiver

Software: TSR   Size: 6,5 x 5 x 4,5 cm
Antenna: External (provided with the USB Radio Receiver)
Communication: USB (no driver installation required), cable provided
Transmission Range: 250m open space, 80m closed environment
(transmission range may be affected by obstacles of different nature)

 

DiskInterface HS
High temperature and pressure devices high speed reading bay

DiskInterface HS pictureThe DiskInterface HS (High Speed) is the connection bay used for downloading data and programming all the high temperature loggers, both up to 100°C and 140°C, and the PressureDisk series loggers.
Differently from the previous version, it needs no adapter to connect to loggers other than the Disk series.
It allows the communication between the data loggers and its management programs, the SPD, the TS Manager, the PressureDisk software.
It is connected to the PC via a USB cable included with the interface.

DiskInterface HS shows, with every software is used, the battery level of the connected device.
It is very easy and intuitive to be used: the logger's base must be placed on the metal plate while the probe is inserted in the crack of the small plate connected to the rod (for loggers without probe, just let this small plate rest on their top). So, the base always down, the probe always up.
Check the instructions downloadable below for better understanding.
Screwing and unscrewing the screw on the back of the cursor you can adjust the eight of the small plate, according to logger's size. Screw the screw tight to keep the plate in place.
During connection the multi coloured LED on top of the metal rod will show connection status and operations.

DiskInterface HS with loggers

Communication:     USB
Cable:     Included
Data loggers:     Disk series, Radio series, Micro series, PressureDisk series, RHTemp series
Software:     SPD, TS Manager, PressureDisk, Process Monitor, Tecno Calib
Batteries:     N/A
Compliancy:   CE  RoHS
 


Software for Tecnosoft data loggers

HumiPressureDisk  Basic software for PressureDisk and RHTemp

PressureDisk is a basic software, free licenced, to program PressureDisk and RHTemp data logger and download data from them.
It has basic functions such as:
    loggers starting, setting mission's parameters (acquisition step etc.);
    loggers data downloading;
    graph display of the recorded acquisitions;
    export data to excel file.

To communicate with the loggers you will need the DiskInterface HS (see above).

Operating systems:     Windows XP, Vista, 7, 8 (32 and 64 bit)
Data management:     Missions saved in excel files
Data display:     Graph (with zoom), data exportable to excel
F0:     Automatically calculates F0
Communication:     DiskInterface HS
Languages:     English

Process Monitor Lite / Pro

Process Monitor is software for P-Radio and S-Radio loggers only, for food producers, to monitor simultaneously more than one autoclave.

TS Manager

Validation system for autoclave, compatible with FDA 21 CFR Part 11 regulations

The TS Manager has been developed with two main ideas: being 21 CFR Part 11 compatible and being a "must-have" resource for all validators of autoclaves, incubators, pasteurisers and general equipment in the healthcare and food industry.
So it has all the features requested by the FDA regulations and other features that let the user manage all his/her validation for the different customers.
The software meets all requirements of FDA 21 CFR Part 11 regulations and presents some peculiar features meeting some requirements of particular applications.
Following, a general and not exhaustive list of the software main features; to know all functions of TS Manager, refer to the different sections of the manual:
    data in the devices not editable;
    data in software not editable;
    access for each user through login and password;
    client/server setup and shared database;
    multi-user access;
    multi-level users, with different functions for each one;
    recording, not editable, of all carried out operations;
    data analysis through pre-set or customizable parameters;
    possibility of pre and post mission comments;
    visualization in graph, with zoom, and table;
    multi graph analysis;
    theoretical temperature calculation based on pressure in saturated steam environment;
    print of customizable reports;
    data and reports export in HTML and XLS (MS Excel) format.

Loggers supported Loggers supported 
Pasteurdisk and Pasteurdisk Probe
Sterildisk and Sterildisk Probe
PasteurCyl
SterilCyl
PressureDisk
 
PasteurDisk Jumbo
SterilDisk Jumbo
SterilCyl Jumbo
PasteurCyl Jumbo
SterilDisk Can
PasteurDisk Can

All loggers are provided with a calibration certificate SIT (NIST equivalent) traceable.
Calibration is made on different points of temperature and temperature / pressure for the PressureDisk.
If you need special calibration points, ask for availability.
   Data sheet on TS Manager (pdf file, opens in new tab)
 

SPD  Management software for sterilisation data loggers

The SPD software is the management program for the SterilDisk, PasteurDisk, SterilCyl, PasteurCyl, SterilDisk Jumbo, PasteurDisk Jumbo, SterilCyl Jumbo, PasteurCyl Jumbo, SterilDisk Can, PasteurDisk Can, SterilCyl Radio and PasteurCyl Radio dataloggers.

It's easy to use, intuitive and full of options. The communication with the devices is made by the Disk Interface (serial or USB), that allows to start the loggers and download the data from them, setting also the start delay and some notes.
Data are then displayed on graph, with zoom function, and table, exportable in Excel.
It is possible to put two vertical markers (lines) to highlight a particular area of the process, giving a name to the markers too: for example, it is possible to select the beginning and the end of the process, or a particular phase of it, calculating the F0 value for that portion only.

The software calculates the F0 and the PU (pasteurisation units) of the process to evaluate the level of sterilisation or pasteurisation. In the configuration window it is possible to set the parameters for the F0 and PU calculation according to the process you want to monitor.
The software, allows to print complete reports with graph, data table, device serial number, and other notes added by the user.
It is also possible to see the battery status of the connected device.
A special feature gives the possibility to set a stop time for the mission: you can program the logger to automatically stop acquisitions after a certain period expressed in seconds, minutes, hours or days.

The SPD software supports the wireless datalogger for pasteurisation and sterilisation too, PasteurCyl Radio and SterilCyl Radio. Through the USB Radio Receiver you will be able to receive data real time from your process. You will see the data one after another, you will be able to assign an alarm profile (on F0/PU values and temperature values to be reached) and you can choose up to 4 sensors (that can be selected any time) to display a graph both for the temperature and the dynamic F0/PU curve.
It is possible to ask to calculate F0/PU only for certain curves and exclude the other sensors from the statistics.
It is possible to download the user's manual in PDF format and the last software update (the full software is necessary to run properly). Download the file .zip and follow the instructions in the README.TXT inside it. It is necessary to install Microsoft .NET 4.0 to make this update run: you can download it from Microsoft website, in your OS language.

Operating systems:     Windows XP, Vista, 7, 8 (32 and 64 bit)
Data management:     Missions sorted by start date and logger serial number
Data display:     Graph (with zoom) and table (exportable into Excel),
        markers for process start and end and printed report of all the data
Multi Graph Display:     Two or more missions can be displayed on a single graph
Real time display:     With the radio function it displays real time the temperature graph and the F0 or PU graph of up to 4 loggers choosed among all the loggers received.
F0 and PU:     Automatically calculates the F0 and PU and the Z and N parameters of the formula can be set
CFR21 Part 11 compatibility:     Data cannot be changed
Communication:     Serial (RS232) or USB
Languages:     English, Italian, French, German, Spanish

 

SterilCyl Radio and PasteurCyl Radio Loggers

 

Thermochron high-temp loggers - to 125 or 140°C

The Thermocron temperature logger is an incredibly small and easy to use device that is a fraction of the price of every other temperature logger on the market.
Their small size and sturdy construction make them ideal for wet and rough conditions.
Their low price make them ideal for tracking everything from individual fridges to individual shipments.
They can be housed in the iButton Capsule (see below) in adverse environments.
Standard devices have temperature ranges:
     -40° to 85°C,     +15°C to +140°C,     or     -5°C to 25°C for fridge loggers.

ThermochronHigh Temperature Thermocron, to 125 or 140°C

TCU Ultra model, +15°C to 140°C,
Resolution 0.5°C/0.0625°C,    8000/4000 readings: $199+GST
Accuracy between +110°C to +140°C is ±1.5°C.
For the remaining range it is ±7°C. Please enquire.

TCX Extreme model, 0°C to 125°C,
Resolution 0.5°C/0.0625°C,    8000/4000 readings: $140+GST

Also required:

eTemperature Kit, includes USB interface and software: $155+GST

    Detailed data sheet on DS1922E (opens new tab or window)

To get started all you need is: one Kit which includes the reader, software and case, plus
your choice of Thermocrons (generic, fridge, or room/body temperature)
Optionally: fobs to assist in the handling of the Thermocrons.

    FAQ on Thermocron Loggers (this site, opens new tab)

    Other Thermochron loggers and more information about Thermochrons (this site, opens new tab)

iButton Capsule mechanical enclosure

The iButton® Capsule is a mechanical enclosure to protect Temperature Logger iButtons (DS1921 and S1922 series) from moisture, solvents and pressure.
The device consists of a base with the cavity for a F5 iButton, a screw-in plug with O-ring to seal the enclosure, and a top with two stainless-steel screws to mount the iButton Capsule to a cable, e.g., to measure temperature at different levels within a liquid.
The cable is inserted into the notch of the plug where it is held in place by the matching protrusion of the top piece.
    Data sheet on iButton Capsule (.pdf file, opens new tab or window)

Note that the logger cannot be connected to a PC whilst in the capsule – it must be removed from the capsule for setup and downloading data.

Applications: Autoclave Sterilization, Seawater temperature profiling
Monitoring of beverage production, Scientific research

iButton® Capsule: $79+GST for small quantities, currently in stock in Australia.

 

 

Computer Products

Communication Products

Measurement Products

Lab Products

 

Contact us for more info:

Phone: +61 2 9481 7420