Flus Professional Environmental Meters
Humidity, Temperature, IR, Sound, Light, Anemometer, Carbon Monoxide CO Thermocouple Data LoggerFlus Professional Environmental Meters
On this page:
Other related pages:
Flus Professional Environmental Meters
ET-951 Professional Humidity & Temperature Meter
Features:
- Temperature units: ℃/℉
- MAX record
- MIN record
- Data hold
- Dew Point Temperature
- Backlight
- Resolution 0.1%RH, 0.1℃
- Calibration function
Specifications:
Humidity | Measuring range | Accuracy |
0~ 100%RH | 40%~60%RH: ±2.0% | |
20%~40%RH;60%~80%RH: ±3.0% | ||
0~20%RH;80%~100%RH: ±4.0% | ||
Temp. |
-35℃~100℃ -31℉~212℉ |
-35℃~-10℃, 70℃~100℃: ±1.0℃ |
-10℃~70℃ : ±0.5℃ | ||
-31℉~+14℉,158℉~212℉: ±1.8℉ | ||
14℉~158℉: ±0.9℉ | ||
Dew Point Temp. |
-35~100℃ -31℉~212℉ |
25℃,40%~100%RH : ±1.0℃(±1.8℉) |
Response time | 1second | |
Sampling rate | 2 times per second | |
Resolution | 0.1%RH, 0.1℃ | |
Working Temp. | -30℃ to 60℃ | |
Power Resource | 9V battery | |
Dimension (L*W*H) | 185*66*33(mm) | |
Weight | 237g |
Datasheet on ET-951 Professional Humidity & Temperature Meter (pdf, opens in a new tab)
ET-952 Professional Light Meter
Features:
- Measuring range: 0Lux~400kLux/0Fc~40kFc (Measurement repeatability)
- Analog bar-graph indication
- Real time and date display
- High accuracy
- Data hold
- Meter corrected for spectral relative efficiency
- Automatically revise parameters for onstandard illumination
- Short rise and fall times
- Selectable measuring units: Lux or Fc
- Meter automatically shuts down after approx. 15 minutes of inactivity
- MAX/MIN record
- Large LCD display
- Peak-hold
- 4-level selectable measurement ranges
- Automatic measurement
- Low battery indication
Specifications:
Display | 4 digits LCD display |
Measuring range | 0 Lux~400k Lux;0Fc~ 40k Fc |
Spectral response | CIE photopic (CIE human eye response curve) |
Over range indication | LCD displays “-OL-” or “-LO-“ |
Spectral accuracy | CIE Vλ function(f1’≦6%,f2’≦2%) |
Accuracy |
±3% rdg±0.5%f.s.(<10,000Lux); ±4% rdg±10dgts.(>10,000Lux) |
Sampling rate | 2 times per second |
Photo detector | Silicon photo-diode with spectral response filter |
Power supply | One 9V battery, 006P, NEDA1604 or IEC6F22 |
Photo detector Lead Length | approx. 2.5m |
Dimension(L*W*H) | 185*66*33(mm) |
Weight | 308g |
Datasheet on ET-952 Professional Light Meter (pdf, opens in a new tab)
ET-953 Digital sound level meter
Features:
- Comply with IEC61672-1 CLASS2 Standard
- Max/Min Record
- Over range indication
- Under range indication
- A & C Weighting
- FAST & SLOW response
- Time and Date display
- Analog AC/DC outputs for connection to frequency analyzer or X-Y shaft recorder
Specifications:
Applied standard | IEC61672-1 CLASS2 |
Accuracy | ±1.4dB |
Frequency range | 31.5Hz~8kHz |
Dynamic range | 50dB |
Measuring level range | Lo:30dB~80dB |
Med:50dB~100dB | |
Hi:80dB~130dB | |
Auto:30dB~130dB | |
Frequency weighting | A & C |
Time weighting: | FAST 125ms;SLOW ( 1s ) |
Microphone | 1/2 inch electret condenser microphone |
Display | 4digits LCD display with a resolution of 0.1dB |
Sampling time | 2 times/sec |
Max Hold | MAX |
Min Hold | MIN |
HOLD: | Hold the readings |
Alarm function | “OVER”is when input is more than upper limit of range. |
“UNDER”is when input is less than lower limit of range. | |
Analog output |
AC/DC outputs from earphone outlet AC=1Vrms ,DC=10mV/dB |
Auto power off | Meter automatically shuts down after approx. 15 minutes inactivity. |
Power supply | One 9V battery, 006P or IEC 6F22 or NEDA 1604. |
Battery life | at least 30 hours |
Operating conditions | -20℃~60℃; 10%RH~90%RH |
Storage conditions | -20℃~60℃; 10%RH~75%RH |
Dimension (L*W*H) |
252*66 *33 mm |
Weight: | 262g |
Datasheet on ET-953 Digital sound level meter (pdf, opens in a new tab)
ET-955 Professional Anemometer
Features:
- C/f temperature selectable.
- Measures air velocity in m/sec. ft/min. km/sec. knots or mph.
- Measures volume in CMM/CFM.
- 55mm hi-contrast LCD display with backlight and function indicators.
- Dual display for velocity and temperature.
- 12 segment bargraph for velocity.
- Average multiple readings for velocity or flow volume for the last 30 readings.
- Auto power off.
- Low battery indication.
Specifications:
Circuit | based on fast and high accurate MCU design |
Display | supper large LCD |
Sampling time | 1time/second |
Temperature measuring | High accuracy NTC resistance |
Temperature range | -30℃~60℃/ -22℉~140℉ |
Temperature accuracy | ±1.5℃/±2.7℉ |
Air velocity range | 0.3m/s ~ 45.0m/s |
Operation Temperature | -10℃~60℃/14℉~140℉ |
Operating Humidity | ≤90%RH(Non-condensation) |
Storage Temperature | -10℃~60℃/14℉~140℉ |
Air velocity level indication | level 1-12 by analog bar-graph, level 12 above by digits |
Measurement average | 0 points average for air flow |
Maximum / Minimum | MAX/MIN |
Reading freezing | Hold |
Area set | 0.001 ~9999 ㎡(0.001~ 9999ft²) |
Power Supply |
one 9V battery with type of 006P、 NEDA1604 or IEC6F22 |
Auto power off | Automatically power off after approx. 15 minutes of inactivity |
Resolution |
m/s:0.01、km/h:0.1、ft/min:1、knots:0.1 mph:0.1、cmm:0.001、cfm:0.001 |
Dimension(L*W*H) | 185* 66*33mm |
Weight | 311g |
Datasheet on ET-955 Professional Anemometer (pdf, opens in a new tab)
IR-810, IR-811, IR-812 Infrared Thermometer 12:1
Features:
- Distance to spot size ratio is 12 to 1 at the focal point.
- Unique flat surface,mini modern housing design.
- Class II laser to identify the centre point of the area being measured.
- Impact-resistant ABS case.
- Auto data hold when trigger released.
- Auto power off.
- Backlighting illuminates display for taking measurement at night or in areas with low background light levels.
- Fixed emissivity at 0.95.
Specifications:
Range |
-50℃~330℃ / -58℉~626℉————IR-810 -50℃~500℃/-58℉~932℉——-IR-811 -50℃~800℃/-58℉~1472℉-IR-812 |
Accuracy |
-50℃~0℃ / -58~32℉ :±4℃ / 7℉ 0℃~330℃ / -32~626℉ :±2% ±2℃ / 4℉————–IR-810 |
-50℃~0℃ / -58℉~32℉ :±4℃ / 7℉ 0℃~500℃/32℉~932℉:±2% ±2℃/4℉-IR-811 |
|
-50℃~0℃ / -58℉~32℉ :±4℃ / 7℉ 0℃~800℃/32℉~1472℉:±2% ±2℃/4℉———-IR-812 |
|
Field of View | D:S= Approx. 12:1 (D=distance, S=spot) |
Response Time | <1s |
Emissivity | fixed at 0.95 |
Resolution | 0.1℃/℉ |
Spectral Response | 8~14um |
Over-Range Indication |
“HI” indicates exceed upper temperature limitation. “LO” indicates exceed low temperature limitation. |
Polarity Display | Auto display, “-”indicates negative, while positive with no sign. |
Diode Laser | Output<1mW,630~670nm,class2(Ⅱ) |
Automatic Power Off | Meter shuts off automatically after 20 seconds of inactivity |
Operating Temperature | 0℃ ~50℃ / 32℉ ~ 122℉ |
Storage Temp | -20℃ ~ 60℃ /-4℉ ~ 140℉ |
Relative Humidity | Operating Humidity:10 to 95%RH;Storage Humidity:<80%RH |
Power Supply | one 9V battery |
Weight | 145g |
Dimensions (H*W*D) | 134*88.5*36mm |
Accessories: User’s Manual, 9V Battery, Blister Card and Clamshell
Datasheet on IR-810, IR-811, IR-812 Infrared Thermometer 12:1 (pdf, opens in a new tab)
IR-801 Infrared Thermometer -50 to 350°C 13:1
Data Hold, Auto power off
Features:
- Distance to spot size ratio is 13 to 1 at the focal point.
- Unique flat surface,mini modern housing design.
- Class II laser to identify the centre point of the area being measured.
- Max/min memory.
- Impact-resistant ABS case.
- Auto data hold when trigger released.
- Auto power off.
- Backlighting illuminates display for taking measurement at night or in areas with low background light levels.
- Fixed emissivity at 0.95.
Specifications:
IR-801 | IR-802 | IR-803 | |
Range | -50~350℃;-58~662℉ | -50~550℃;-58~1022℉ | -50~850℃;-58~1562℉ |
Accuracy | -50℃~0℃: ±4℃ | -50℃~0℃:±4℃ | -50℃~0℃:±4℃ |
0℃~350℃:±2% ±2℃ | 0℃~550℃:±2% ±2℃ | 0℃~850℃:±2% ±2℃ | |
Emissivity | fixed at 0.95 | ||
Optical Resolution | D:S=13:1 | ||
Resolution | 0.1℃(0.1℉) | ||
Spectral Response | 8~14um | ||
Polarity Display | Auto display, “-” indicates negative, while positive with no sign. | ||
Diode Laser | Output<1mW,630~670nm,class 2(Ⅱ) | ||
Auto Power Off | Auto shuts off after 20 seconds inactivity | ||
Operating Temp. | 0℃ to 50℃ / 32℉ to 122℉ | ||
Storage Temp. | -20℃ to 60℃ / -4℉ to 140℉ | ||
Relative Humidity | Operating:10~95%RH,Storage:<80%RH | ||
Power Supply | 9V battery | ||
Dimensions(L*W*H) | 155.5*98.8*27.5mm | ||
Weight | 176g |
Accessories: User’s Manual, 9V Battery, Tripod(Optional), Gift box with carrying pouch.
Datasheet on IR-801 Infrared Thermometer -50 to 350°C 13:1 (pdf, opens in a new tab)
IR-808 30:1 wide range infrared thermometer 30:1
Features:
- Distance to spot size ratio is 30 to 1 at the focal point.
- Unique flat surface, mini modern housing design.
- Class II laser to identify the centre point of the area being measured.
- Max/min memory.
- Impact-resistant ABS case.
- Auto data hold when trigger released.
- Auto power off.
- Backlighting illuminates display for taking measurement at night or in areas with low background light levels.
- Adjustable emissivity from 0.1 to 1.0.
- wide range temperature measurements.
Specifications:
|
IR-806 | IR-808 | IR-809 |
Range |
-50℃~650℃ -58℉~1202℉ |
-50℃~850℃ -58℉~1562℉ |
-50℃~1050℃ -58℉~1922℉ |
Accuracy |
-50℃~0℃/ -58℉~32℉:±4℃/9℉ |
-50℃~0℃/ -58℉~32℉:±4℃/9℉ |
-50℃~0℃/ -58℉~32℉:±4℃/9℉ |
0℃~650℃/ -32~1202℉: 1.5% ±2℃/4℉ |
0℃~850℃/ -32℉~1562℉: 1.5% ±2℃/4℉ |
0℃~1050℃/ -32℉~1922℉: 1.5% ±2℃/4℉ |
|
Optical Resolution | D:S=30:1 | ||
Emissivity | Adjustable: 0.10~1.0 | ||
Resolution | 0.1℃/0.1℉﹤1000 1℃/1℉≥1000 | ||
Response Time | ﹤250 ms | ||
Spectral Response | 8~14um | ||
Polarity Display | Auto display, “-” indicates negative, while positive with no sign. | ||
Diode Laser | Output<1mW,630~670nm, class 2(Ⅱ) | ||
Auto Power Off | Auto shuts off after 20Sec. of inactivity | ||
Operating Temp. | 0℃ to 50℃ / 32℉ to 122℉ | ||
Storage Temp. | -20℃ to 60℃ / -4℉ to 140℉ | ||
Relative Humidity |
Operating:10 to 95%RH Storage:<80%RH |
||
Power Supply | 9V battery | ||
Weight | 171g | ||
Dimensions (L*W*H) |
155.5*98.8*27.5mm |
Accessories: User’s Manual, 9V Battery, Tripod(Optional), Gift box with carrying case
Datasheet on IR-808 30:1 wide range infrared thermometer 30:1 (pdf, opens in a new tab)
IR-809 Infrared Thermometer -50° to 1050° – 30:1
Features:
- Distance to spot size ratio is 30 to 1 at the focal point.
- Unique flat surface,mini modern housing design.
- Class II laser to identify the centre point of the area being measured.
- Max/min memory.
- Impact-resistant ABS case.
- Auto data hold when trigger released.
- Auto power off.
- Backlighting illuminates display for taking measurement at night or in areas with low background light levels.
- Adjustable emissivity from 0.1 to 1.0.
- wide range temperature measurements.
Specifications:
|
IR-806 | IR-808 | IR-809 |
Range |
-50℃~650℃ -58℉~1202℉ |
-50℃~850℃ -58℉~1562℉ |
-50℃~1050℃ -58℉~1922℉ |
Accuracy |
-50℃~0℃/ -58℉~32℉:±4℃/9℉ |
-50℃~0℃/ -58℉~32℉:±4℃/9℉ |
-50℃~0℃/ -58℉~32℉:±4℃/9℉ |
0℃~650℃/ -32~1202℉: 1.5% ±2℃/4℉ |
0℃~850℃/ -32℉~1562℉: 1.5% ±2℃/4℉ |
0℃~1050℃/ -32℉~1922℉: 1.5% ±2℃/4℉ |
|
Optical Resolution | D:S=30:1 | ||
Emissivity | Adjustable: 0.10~1.0 | ||
Resolution | 0.1℃/0.1℉﹤1000 1℃/1℉≥1000 | ||
Response Time | ﹤250 ms | ||
Spectral Response | 8~14um | ||
Polarity Display | Auto display, “-” indicates negative, while positive with no sign. | ||
Diode Laser | Output<1mW,630~670nm, class 2(Ⅱ) | ||
Auto Power Off | Auto shuts off after 20Sec. of inactivity | ||
Operating Temp. | 0℃ to 50℃ / 32℉ to 122℉ | ||
Storage Temp. | -20℃ to 60℃ / -4℉ to 140℉ | ||
Relative Humidity |
Operating:10 to 95%RH Storage:<80%RH |
||
Power Supply | 9V battery | ||
Weight | 171g | ||
Dimensions (L*W*H) |
155.5*98.8*27.5mm |
Datasheet on IR-809 Infrared Thermometer -50° to 1050° – 30:1 (pdf, opens in a new tab)
IR-866 Infrared Thermometer IR-866 -50° to 2250° – 50:1
Features:
- C/f setting
- Built-in laser point increase the target increase
- Automatic data hold
- Auto power off
- White backlit LCD display
- Overrange indication
- High temperature
- MAX,MIN,DIF,AVG record
- High/low alarm,trigger lock
- Adjustable emissivity
- Data record
Specifications:
Range | -50~1150℃ | -50~1350℃ | -50~1650℃ | -50~1850℃- | -50~2250℃ | |
-58~2102℉ | -58~2462℉ | -58~3002℉ | 58~3362℉ | -58~4082℉ | ||
Assumes ambient operating temperature of 23~27℃ (73 ~80℉) | ||||||
Accuracy | -50℃~0℃(-58℉~32℉):±3℃(5.4℉) | |||||
0℃~500℃(32℉~932℉):1.0% ±1℃(1.8℉) | ||||||
500℃~1000℃(932℉~1832℉):1.5%±2℃(4℉) | ||||||
Above 1000℃/1832℉:2.0%±2℃(4℉) | ||||||
Optical Resolution | D:S=50:1 | |||||
Emissivity | Adjustable: 0.10~1.0 | |||||
Resolution | 0.1℃(0.1℉)﹤1000;1℃(1℉)﹥1000 | |||||
Response Time | ﹤250ms | |||||
Spectral Response | 8~14um | |||||
Polarity Display | Auto display, “-” indicates negative, while positive with no sign. | |||||
Diode Laser | Output<1mW,630~670nm, class 2(Ⅱ) | |||||
Automatic Power Off | Meter shuts off automatically after 20 seconds | |||||
Operating Temp. | 0℃~50℃(32℉~122℉) | |||||
Storage Temp. | -20℃~60℃(-4℉~140℉) | |||||
Relative Humidity | Operating:10 to 95%R;Storage:<80%RH | |||||
Power Supply | 9V battery | |||||
Weight | 290g | |||||
Dimensions(L*W*H) | 191.5*126*60mm |
CO-910 Mini Carbon Monoxide Meter
The meter indicates the presence of CO by a reading on the LCD and a beeper tone.
Features:
- Sensor: Stabilized electro-chemical Gas-specific
- Measurement range: 0 ~ 1000 PPM
- High accuracy
- Large LCD display
- Accuracy is not affected by humidity
- Sensor drift is small, so that the measurement reading is stable
- Compact, light and easy to carry
- Low battery consumption, long battery life.
Specifications:
Accuracy | 5%±10PPM |
Measurement Resolution | 1PPM |
Data update | 2 times/second |
Fast sampling Time | 2 times/second |
Response Time | ﹤30S |
Zero Drift | ﹤5PPM |
Repeatability | ±2% |
Long-time stability | <5%/year |
Operating Conditions | -20~50℃; 15% ~90%RH |
Storage Conditions | -30~50℃; 0%~80%RH |
Audible Alarm | ≧35PPM and ≧200PPM |
Auto zero | √ |
Backlight | auto shut off after 30 secs of inactivity |
Auto power off | after 15 minutes of inactivity |
Typical sensor life | About 5 year |
Accessories: User’s manual, 9V battery, carrying case, gift box*
ET-959 / ET-959B K-type / J-type Thermocouple Thermometers
Features:
- User selectable C/F
- Type K/j thermocouple
- Single/Dual thermocouple input
- Wide variety of interchangeable thermocouple probes
- Max/Min/AVG record
- differential temperature
- Scan function
- LCD display with backlight
Specifications:
Range | Type K | -200℃ ~1370℃(-328℉~2498℉) |
Type J | -200℃ ~ 1100℃(-328℉~2012℉) | |
Accuracy | Type K | -200℃~0℃(-328℉~32℉);±(0.5%rdg+2℃/3.6℉) |
0℃~1000℃(32℉~1832℉);±(0.15%rdg+1℃/1.8℉) | ||
1000℃~1370℃(1832℉~2498℉);±(0.5%rdg+1℃/1.8℉) | ||
Type J | 200℃~0℃(-328℉~32℉);±(0.5%rdg+2℃/3.6℉) | |
0℃~1000℃(32℉~1832℉);±(0.15%rdg+1℃/1.8℉) | ||
1000℃~1100℃(1832℉~2012℉);±(0.5%rdg+1℃/1.8℉) | ||
Resolution | 0.1℃/ ℉ <1000 , 1℃ / ℉ / > 1000 | |
AVG | The average value for latest 10 readings | |
Power Supply | 9V battery | |
Power Life | At least 30 hours | |
Operating conditions | -20℃~60℃,10%RH~90%RH | |
Storage conditions | -20℃~60℃,10%RH~75%RH | |
Dimensions(L*W*H) | 185*66 *33 mm | |
Weight | 245g |
Accessories: User’s manual, 9V battery, type K/J temperature probe, USB cable, adaptor, software, tripod (optional), carrying case
ET-960 / ET-961 K-type / J-type Thermocouple Thermometers with Data Logger
Features:
- User selectable C/F
- Type K /j thermocouple
- Single/Dual /four thermocouple input
- wide variety of interchangeable thermocouple probes
- Max/Min/AVG record, data hold
- differential temperature
- Scan function
- LCD display with backlight
Specifications:
Range | Type K | -200℃ ~1370℃(-328℉~2498℉) |
Type J | -200℃ ~ 1100℃(-328℉~2012℉) | |
Accuracy | Type K | -200℃~0℃(-328℉~32℉);±(0.5%rdg+2℃/3.6℉) |
0℃~1000℃(32℉~1832℉);±(0.15%rdg+1℃/1.8℉) | ||
1000℃~1370℃(1832℉~2498℉);±(0.5%rdg+1℃/1.8℉) | ||
Type J | -200℃~0℃(-328℉~32℉);±(0.5%rdg+2℃/3.6℉) | |
0℃~1000℃(32℉~1832℉);±(0.15%rdg+1℃/1.8℉) | ||
1000℃~1100℃(1832℉~2012℉);±(0.5%rdg+1℃/1.8℉) | ||
Resolution | 0.1℃/ ℉ <1000 , 1℃ / ℉ / > 1000 | |
AVG | The average value for latest 10 readings | |
Power Supply | 9V battery | |
Power Life | At least 30 hours | |
Operating conditions | -20℃~60℃,10%RH~90%RH | |
Storage conditions | -20℃~60℃,10%RH~75%RH | |
Dimensions (L*W*H) |
185*66*32.8mm | |
Weight | 245g |