Temperature
only loggers, with internal and external sensors, some with
Alarm LEDs, and/or LCD display
Temperature
and Humidity Loggers x
fbb
Prices
(Australian dollars) do not include GST and may change without notice.
Go
up one level to see other makes of data loggers, etc: click here
IP Ratings Chart: click here NEMA to IP Ratings
Batteries for Escort
Loggers: 3.6V Lithium half AA
size (cylindrical), replaceable.
The top and bottom of the loggers unscrew
from each other. The O-Ring seal should be greased with silicon grease.
JA-BAT 1/2 AA 3.6V Lithium battery for Junior
and iLog: $30+GST 8/07
40K
memory for Esort Junior Loggers:
MEM40: Upgrade from
16K to 40K logger memory for standard Junior loggers: $60+GST 8/07
(Not
available for thermocouple or high temperature loggers).
when ordered with new logger
Product code of
40K logger is EJ-[XX]-[R(R)]-40-[Options].
Product
code example: EJ-IN-D-40-L
D range: -40° to +70° C, average resolution 0.5° C
Graphs: Accuracy (.pdf file) Resolution (.pdf file)
-T
option: Logger-specific ISO 9002 Traceable Temperature Certification
for D Range loggers $POA
(3 points at -15°C,
0°C and +25°C).
The -T Option needs to be specified for the logger
when ordered.
The certificate is only valid for a single logger. (Product
code example, add -T at end: EJ-IN-D-16-L-T)
Note that the loggers
are actually calibrated (adjusted) during this procedure, it's not just a measurement.
Customers can return the loggers for recalibration every year as required.
NT11 NATA Certification one sensor, one temp point,-30
to +100 $90+GST These
prices need to be checked.
NT12 NATA Certification
one sensor, two temp point,-30 to +100 $103
NT13 NATA
Certification one sensor, three temp point,-30 to +100 $115
NT1H1
NATA Certification single temp point - -20C to + 60C & single point
Humidity $205
NT1H2 NATA Certification single temp
point - -20C to + 60C & two point Humidity 33% and 76% $240
NHSET
Reset Set Points in Humidity Logger to 33% and 76% $115
Download Escort Logger User Manual (.pdf 550KB): click here
Temperature and Humidity LoggersJump to:
EJ-HS Temperature & Humidity
logger: click here (jumps to separate page) fbb
There
is one Temperature and Humidity logger in the Escort Junior (EJ) range.
Escort iLog Loggers for Temperature & Humidity - iLog: 1 & 2 ch, have many extra features

Also
required with Escort Loggers:
Escort
Junior Interface and Windows software
Interface and
Software to read the data out of an Escort Junior logger
required for all Escort Junior modules.
EA-INT-U
Serial Interface for Escort Loggers, Universal: $137.12 +GST
has
a serial RS-232 connection and works with 8/07
Sp
Escort iLog, Junior, Autoclave
and Precision loggers
EA-INT-USB Interface
for Escort Loggers, Universal, with USB interface: $158.34 +GST 8/07
Sp
has a USB connection and works
with
Escort iLog, Junior, Autoclave and Precision loggers
JA-SWP-WIN Software for Escort Data Logger: free download: click here
Options:
JA-KEY
Escort Keyring magnet to start loggers $20+GST
Starting
an Escort Logger without a magnet: click here (jumps to end of this page)
EA-ALK
Escort Alarm Link,
triggers relay output upon
audible alarm of Junior or iLog, resembles interface $173.93 +GST 8/07
Sp
(Autoclave units also require an adaptor: TN-HJ-JA-INTACA. Autoclave loggers are discontinued)
Sensors
(thermistor type):
Temperature Ranges D -40/70° C,
accuracy ±0.3° C, resolution 0.1° C fbb
Graphs of D Range: Accuracy
(.pdf file) Resolution
(.pdf file)
External sensor only: C -20/100° C, accuracy ±0.3°
C, res 0.1° or 0.2°C
External sensor only: Z 0/150°
C, accuracy ±0.3° C, res 0.1° C
Pulse Count interface: P or Q, Records signals of pulse per units time. Special dedicated input.
FAQ on Escort loggers: click here
Download
Windows Software Demo
which simulates interaction with an Escort logger:
click here
Download Escort User Manual: click here
EJ-IN
Temperature Loggers
Temperature Ranges:
A:
-40/40° C, average resolution 0.3° C | B: -20/60°
C, average resolution 0.3° C |
D:
-40/70° C, average resolution 0.5° C | T: -5/20°
C, average resolution 0.1° C
(internal temp.
sensor, 16K memory, Alarm LEDs, -40/70°C, Sp
average resolution
0.5° C (range D) IP66 EJ-IN
data (.pdf file, opens new window)
EJ-TS-D-2 Junior
with internal "D" range sensor, 2K memory, IP65, no LEDs $180.80 +GST
8/07 Sp
EJ-IN-D-2
Junior with internal "D" range sensor,
2K memory $189.17+GST
EJ-IN-D-16
Junior with internal "D" range sensor, IP65,
LEDs $221.21 +GST
EJ-IN-D-16-L
Junior with internal "D" range sensor, IP65, LEDs and display
$282.46 +GST
Internal temperature sensor, plus external temperature sensor
which is optionally thermistor or PT1000.
Alternatively the logger can be
configured to measure thermocouple (K type)
or analog signals
(0~10V/0~1V/0~20mA) but without internal temperature sensor. EJ-1E
data (.pdf file, opens new window)
All have LEDs, -L versions have LCD Display
EJ-1E-D-16 Junior
with internal and external D range sensor, IP51,LEDs $390.84
8/07 Sp
EJ-1E-D-16-L
Junior with internal and external D range sensor, IP51
,LEDs & LCD display $376.45
EJ-1E-DC-16 Junior
with internal D range and external C range sensor, IP51,LEDs $366.02
EJ-1E-DC-16-L Junior with internal D range and external C range sensor,
IP51,LEDs & LCD display $438.04
EJ-1E-DN-16 Low
Temperature Range Junior, external -100°C to +40°C, 16K memory $420.21
EJ-1E-DN-16-L Low Temperature Range Junior, external -100°C to +40°C,
16K memory, IP51, LEDs and LCD $527.32
EJ-2E data (.pdf file, opens new window)
EJ-2E-C-16 Junior
with two external C range sensors, IP51, LEDs $592.92
+GST 8/07 Sp
EJ-2E-C-16-L
Junior with two external C range sensors, IP51,LEDs & LCD display $660.53
EJ-2E-D-16 Junior with two external D range
sensors, IP51, LEDs $537.71
EJ-2E-D-16-L Junior with two external D range sensors, IP51,Leds &
LCD display $590.92
with LEDs
EJ-HS-B-16 Junior with "B" range air temperature sensor and standard
humidity sensor, IP51, with LEDs
with LEDs and LCD display
EJ-HS-B-16-L
Junior with "B" range air temperature sensor and standard humidity sensor,
IP51, with LEDs and LCD
Jump to separate
page on Temp. & Humidity loggers
Required accessories: Interface
EA-INT, Console Software JA-SWP-WIN
and key ring JA-KEY.
EJ-OE-K5-16
Thermocouple Junior for K-Type
Thermocouple sensor input via adapter, measuring 0°C to 500°C,
no internal sensor, IP51, LED's $644.37
+GST 8/07 Sp
EJ-OE-K5-16-L
Thermocouple
Junior for K-Type Thermocouple sensor input via adapter, measuring 0°C
to 500°C,
no internal sensor, IP51, with LCD and LEDs $734.95
EJ-OE-M-16-L Body Temperature Range Junior, 20°C
to +45°C, with LEDs and LCD,
16K memory, IP51 $909.89
EJ-OE-U-16
Analogue Junior for recording of power or current
via screw terminal adapter, no internal sensor,
16K memory, IP51, LEDs $567.16
EJ-PS-D-16
Pulsecount Junior for recording pulses, internal
D range temperature sensor,
16K memory, IP51, LEDs $411.56
Thermocouple Loggers EJ-OE-K data (.pdf file, opens new window)
Note: these require JA-INT Interface and software (as do all the Escort Juniors), see above.
TE-D-28-KK-30
Thermocouple wire (about 1mm dia) , 30m, with plug, welded junction
exposed $55+GST
TW-T32-TXTW K-type teflon twisted
wire, when purchased with logger, per metre: $6+GST
Also
required with Escort Loggers:
Escort
Junior Interface and Windows software
Interface and
Software to read the data out of an Escort Junior logger
required for all Escort Junior modules.
EA-INT-U
Serial Interface for Escort Loggers, Universal: $137.12 +GST
has
a serial RS-232 connection and works with 8/07
Sp
Escort iLog, Junior, Autoclave
and Precision loggers
EA-INT-USB Interface
for Escort Loggers, Universal, with USB interface: $158.34 +GST 8/07
Sp
has a USB connection and works
with
Escort iLog, Junior, Autoclave and Precision loggers
JA-SWP-WIN Software for Escort Data Logger: free download: click here
JA-KEY Escort Keyring magnet to start loggers $20+GST
HJ-IN-V data (.pdf file, opens new window) See also ACR Nautilus Logger: 10°C to 135°C
HJ-1E-VZ-16
High Temp. Junior, internal and external sensor, 16K memory,
IP51, LEDs DISCONTINUED
HJ-AC-ZY-2-SI
See more descriptions below.
High Temperature Logger for
ovens and autoclaves rated to 150°C at 5 bar for 30 minutes or 60 minutes
at
normal pressure (if starting from room temperature), external sensor in
50mm stub probe, stainless
steel/PEEK case, IP68, 2K memory DISCONTINUED
HJ-FP-V-16-CI
High Temp Junior logger with two external sensors, both
encapsulated (axial probe 60mm with M6 thread,
radial probe 25mm), stainless
steel case, IP68, 16K memory $1,258.59 S
HJ-IN-V-16 High
Temp. Junior, internal sensor, 16K memory, IP65, LEDs
HJ-IN-V-16-CEI
High Temp Junior, stainless steel case, IP68, internal sensor in encapsulated
80mm stub probe (exchangeable),
16K memory $1,045.17
8/07
HJ-IN-V-16-CI High Temp Junior, stainless
steel case, IP68, internal sensor in 25mm stub probe (exchangeable), 16K mem $1,045.17
HJ-IN-V-2 High Temp. Junior, internal sensor, 2K memory. LEDS $66.66 8/07 Sp
HJ-PD-V-16 High
Temp. Junior with internal and encapsulated external sensor for fast response
times or immersion, with
LED's, 16K memory DISCONTINUED
HJ-SRV-AC-BAT Battery replacement service for HJ-AC-ZY-2-SI $550.00 8/07 S
HJ-AC-ZY-2-SI
High temperature 150°Autoclave logger
DISCONTINUED
used for
autoclave compliance verification testing. Data
sheet: click here (.pdf file, opens new window)
Logger designed to
sit inside autoclave during operation. Stainless steel. Data
sheet (mfr site)
Pressure and temperature tested to withstand autoclave
temperatures and pressures (up to +150°C / 5 bar).
For further technical
information, see the Autoclave logger.
External rigid stub probe sensor
is used for sampling environment under test.
+25~150°
C, accuracy ±0.5° C, resolution 0.5° C
Stub
probe temperature response T90 of less than 4 minutes in moving air
Internal
sensor measuring range of 150° C used for diagnostic purposes only.
HJ-AC-ZY-2-SI High temperature Autoclave logger. See above for price.
Autoclaves
work by allowing steam to enter, then maintaining the pressure at 103 kPa (15
psi).
This causes the steam to reach 121 °C, and this is maintained for at
least 15 minutes.
Modern autoclaves operate at higher temperature and pressures.
See also ACR Nautilus Logger: 10°C to 135°C
Special Interface
Adapter:
JA-INT-SSC Interface Adapter for
Stainless Steel Case Loggers is no longer required.
The Autoclave loggers fit
the new versions of the standard interfaces, see below.
JA-KEY Escort Keyring magnet to start loggers $20

Also
required with Escort Loggers:
Escort
Junior Interface and Windows software
Interface and
Software to read the data out of an Escort Junior logger
required for all Escort Junior modules.
EA-INT-U
Serial Interface for Escort Loggers, Universal: $137.12 +GST
has
a serial RS-232 connection and works with 8/07
Sp
Escort iLog, Junior, Autoclave
and Precision loggers
EA-INT-USB Interface
for Escort Loggers, Universal, with USB interface: $158.34 +GST 8/07
Sp
has a USB connection and works
with
Escort iLog, Junior, Autoclave and Precision loggers
JA-SWP-WIN Software for Escort Data Logger: free download: click here
Options:
JA-KEY
Escort Keyring magnet to start loggers $20+GST
Starting
an Escort Logger without a magnet: click here (jumps to end of this page)
EA-ALK
Escort Alarm Link,
triggers relay output upon
audible alarm of Junior or iLog, resembles interface $173.93+GST 8/07
Sp
JA-BAT-EJH130 Replacement battery for High Temp loggers $109.74 +GST 8/07
Escort User Admin Software
for compliance with the US Food and Drug Admin Title 21, Part 11: Click
here
JA-SWP-CON
Standard software package More
info. $236.85 8/07 Sp
JA-SWP-UAP User Admin Package upgrade from the standard SW package.
More info $POA
ESCORT
Cool Down LoggerEC-OE-C-L Escort Cool Down Logger with
LCD for monitoring of cooling process 2h, 4h and 6h
after falling below +60°C.
Integrated interface (DB9). IP51. $208.80 +GST 8/07
Sp
Special software tool required.
JA-SWP-EC Escort Cool Down Logger Software CD
with special software for setting time and preferences for Cool Down Logger,
as well as download and saving of last recorded Cool
Down process. $62.92+GST 8/07 Sp
ESCORT
ThermoCheck TC-MKV ThermoCheck - Portable, handheld temperature meter
and temperature S
Unit
includes rechargeable batteries and interface cable for communication to PC
with attached cable that can be connected to standard 12V /500mA DC Power Adaptor
(not supplied) for battery charging.
TC-MKV
ThermoCheck: $1,462.44 8/07 S
Thermocouple sensor must be ordered separately.
ESCORT ThermoCheck Accessories
TC-DB ThermoCheck data base and communication software for
installing product/location/corrective
action database in ThermoCheck and
downloading recorded data for analysis and record keeping. $251.59
+GST 8/07 Sp
TC-TSN-K0112
K-Type Thermocouple Hypodermic Needle Probe for ThermoCheck $214.55 +GST
8/07 Sp
TC-TSN-K0234 K-Type Thermocouple General Purpose Probe for ThermoCheck
$199.60
TC-TSN-K0454 K-Type Thermocouple Surface
Probe for ThermoCheck $202.03
TC-TSN-K0834 K-Type Thermocouple Air/Between Pack Probe for ThermoCheck
$192.07
TC-TSN-T0112 T-Type Thermocouple Hypodermic Needle Probes
,shaft 60mm,diameter 2mm for ThermoCheck $331.29
TC-TSN-T0234 T-Type
Thermocouple General Purpose Probe shaft 120mm diameter 3mm for ThermoCheck $315.32
TC-TSN-T0454 T-Type Thermocouple Surface Probe,shaft 120mm,diameter
5mm for ThermoCheck $315.32
TC-TSN-T0834 T-Type
Thermocouple Air/Between Pack Probe shaft 120mm,diameter 3mm flat end $319.28

Hazard Analysis and Critical Control Points (HACCP) is a systematic preventive approach to food safety and pharmaceutical safety that addresses physical, chemical, and biological hazards as a means of prevention rather than finished product inspection.
For details see http://en.wikipedia.org/wiki/HACCP
There is no
such thing as HACCAP accreditation or approval for specific equipment.
If applicable, please check the HACCAP manual to see what specifications
are appropriate for your application.
ChartReader for Junior and plastic case High Temp loggers
EJ-CR-MEM Junior ChartReader for downloading and printing logger data. Memory
1MB, IP51.
Interface to logger attached. PC interface required for data transfer
and configuration. $1,069.95 +GST 8/07 S
JA-CHR-INT-E ChartReader Interface for PC, i.e. PC Interface for ChartReader $49.89 +GST 8/07 Sp
With the juniors and iLogs you can start the logger via programming stage in Console without a magnet.
When you go to Program and Configure
>> select In 0 days
.
option (rather than Wait
.after magnet start).
See
screen shot. This is where you put in a start delay.
On the iLog models, a start delay timer will actually count down on the LCD screen.
On Junior LCD display models, you see: p_ _ _ _ _t on the screen
On iLog LCD display models,
you will
see timer: 0:01 (or whatever the delay is)
On Juniors it will just
count down from internally,
and activation beeps will be heard,
followed by the flashing green active light.
* You have to put some sort of delay in to start the logger. (You can put 1 minute as a minimum).