Temperature
only loggers, with internal and external sensors, some with
Alarm LEDs, and/or LCD display
Temperature
and Humidity Loggers x
fbb
Prices
(Australian dollars) do not include GST and may change without notice.
Go
up one level to see other makes of data loggers, etc: click here
IP Ratings Chart: click here NEMA to IP Ratings
Batteries
for Escort Loggers: 3.6V Lithium half AA size (cylindrical), replaceable.
The top and bottom of the loggers unscrew from each other. The O-Ring
seal should be greased with silicon grease.
LS1450 Battery for Junior
and iLogs 1/2 AA lithium, 3.6v $32+GST 3/10
CR2450
Battery for Intelligent Mini data loggers 3 volt $30
40K memory for Esort Junior Loggers:
MEM40: Upgrade from 16K to 40K logger memory for standard Junior
loggers: $69+GST 3/10
(Not
available for thermocouple or high temperature loggers).
when ordered with new logger
Product code of 40K logger
is EJ-[XX]-[R(R)]-40-[Options].
Product code example: EJ-IN-D-40-L
D range: -40° to +70° C, average resolution 0.5° C
Graphs: Accuracy (.pdf file) Resolution (.pdf file)
-T
option: Logger-specific ISO 9002 Traceable Temperature Certification
for D Range loggers $POA
(3 points at -15°C,
0°C and +25°C).
The -T Option needs to be specified for the logger
when ordered.
The certificate is only valid for a single logger. (Product
code example, add -T at end: EJ-IN-D-16-L-T)
Note that the loggers
are actually calibrated (adjusted) during this procedure, it's not just a measurement.
Customers can return the loggers for recalibration every year as required.
NT11 NATA Certification one sensor, one temp point,-30
to +100 $90+GST These
prices need to be checked.
NT12 NATA Certification
one sensor, two temp point,-30 to +100 $103
NT13 NATA
Certification one sensor, three temp point,-30 to +100 $115
NT1H1
NATA Certification single temp point - -20C to + 60C & single point
Humidity $205
NT1H2 NATA Certification single temp
point - -20C to + 60C & two point Humidity 33% and 76% $240
NHSET
Reset Set Points in Humidity Logger to 33% and 76% $115
Download Escort Logger User Manual (.pdf 550KB): click here
Temperature and Humidity LoggersJump to:
EJ-HS
Temperature & Humidity logger: click here (separate page) fbb
There is one
Temperature and Humidity logger in the Escort Junior (EJ) range.
Escort iLog Loggers for Temperature & Humidity - iLog: 1 & 2 ch, have many extra features

Also
required with Escort Loggers:
Escort
Junior Interface and Windows software
Interface and
Software to read the data out of an Escort Junior logger
required
for all Escort Junior modules. See price list below.
EA-INT-U Serial Interface
for Escort Loggers, Universal
has a serial RS-232 connection and
works with
Escort iLog, Junior, Autoclave and Precision loggers
OR
EA-INT-USB Interface
for Escort Loggers, Universal, with USB interface
has a USB connection
and works with
Escort iLog, Junior, Autoclave and Precision loggers
JA-SWP-WIN Software for Escort Data Logger: free download: click here
Options:
JA-KEY
Escort Keyring magnet to start loggers $44+GST 3/10
Starting
an Escort Logger without a magnet: click here (jumps to end of this page)
EA-ALK
Escort Alarm Link,
triggers relay output upon
audible alarm of Junior or iLog, resembles interface
(Autoclave units also require an adaptor: TN-HJ-JA-INTACA. Autoclave loggers are discontinued)
EA-ALK New
version Alarm Link $243+GST 3/10
EA-INT-U
Universal Interface. $157
EA-INT-USB
Universal USB Interface. $180
JA-USB-SER USB to Serial Adaptor.
$87
MN-INT-E Interface Cable for both egg loggers and
Mini 2000 data loggers. Pin-jack connector to logger and Serial interface. $75
D8110B
Male to female serial cable connector
for Intelligent mini and Wireless Mini data loggers. $39
Accessories
MEM40
40k
memory upgrade option for all Junior Data loggers $94+GST 3/10
JA-TSN-K1-1-T
Temp. Probe.Jun.10k.A,B,D and
T range.1m.Tip. $116
JA-TSN-K2-1-T-HT Temp. Probe.Jun.100k.FandZrange.1m.Tip.
$141
JA-TSN-G4-1-T Temp. Probe.Jun.PT1000.N
range.1m.Tip. $15
JA-DFR Dust Filter Accessory for junior temperature and
humidity data logger, models EJ-HS-B16(L) $156
JA-KEY Junior Start Magnet on
Key Ring Chain $44
JA-SWP-CON Escort Console Professional Software v.2.06.09
on CD-Rom.
Features include calculating MKT, PHI, multi-link data logger charts.
Alternatively, can be downloaded $52
JA-SWP-UAP Escort Console
User Admin Package $884
JA-TSN-G4-1-T Junior Temp Sensor, PT1000, 1m, S/S tip,
N-range $156
JA-TSN-K1-1-T Temp Probe, 10K, MCX, PVC, 1m, S/S Tip $116
JA-TSN-K2-1-T-HT
Temp. Probe.Jun.100k.FandZrange.1m.Tip. $141
* For additional probe lengths
i.e. 3 metre, 10 metres etc. for standard and high temperature applications
(K-1-1-T and T-HT),
and un-tipped sensors, please request a quotation.
Sensors
(thermistor type):
Temperature Ranges D -40/70°
C, accuracy ±0.3° C, resolution 0.1° C fbb
Graphs of D Range: Accuracy
(.pdf file) Resolution
(.pdf file)
External sensor only: C -20/100° C, accuracy ±0.3°
C, res 0.1° or 0.2°C
External sensor only: Z 0/150°
C, accuracy ±0.3° C, res 0.1° C
Pulse Count interface: P or Q, Records signals of pulse per units time. Special dedicated input.
FAQ on Escort loggers: click here
Download
Windows Software Demo
which simulates interaction with an Escort logger:
click here
Download Escort User Manual: click here
EJ-IN
Temperature Loggers
Temperature Ranges:
A: -40° to
+40°C | B:
-20° to +60°C |
N: -100° to +40°C
C: -20°
to +100°C | D:
-40° to +70°C |
V: 0° to +125°C
F: +60°
to |
Y: +25° to +150°C | Z:
0° to +150°C
K5: 0 - 500°C | M:
+20° to +45°C | (U: Analogue)
(internal temp. sensor, 16K memory, Alarm
LEDs, -40/70°C,
average
resolution 0.5° C (range D) IP66 EJ-IN
data (.pdf file, opens new window)
EJ-IN-D-2 Junior
temp logger, int, D, 2K, min order 25 $210+GST
3/10
EJ-IN-D-40-L Junior Temp. Logger,
internal, -40°C ~ +70°, 40K, LCD, min order 10 $362
EJ-TS-D-2
Junior Entry Temperature Logger,
-40°C ~ +70°C, 2K, no L, min order 50 $201
MEM40 40k
memory upgrade option for all Junior Data loggers $94
JA-TSN-K1-1-T
Temp. Probe.Junior.10k. A,B,D and T
range.1m.Tip. $116
JA-TSN-K2-1-T-HT Temp. Probe.Junior.100k. FandZrange.1m.Tip.
$141
JA-TSN-G4-1-T Temp. Probe.Junior.
PT1000. N range.1m.Tip. $156
Batteries
LS1450 Battery for Junior
and iLogs 1/2 AA lithium, 3.6v $32
CR2450 Battery for Intelligent Mini data
loggers 3 volt $30
Internal temperature sensor, plus external temperature sensor which is optionally
thermistor or PT1000.
Alternatively the logger can be configured to measure
thermocouple (K type)
or analog signals (0~10V/0~1V/0~20mA) but
without internal temperature sensor. EJ-1E
data (.pdf file, opens new window)
All have LEDs, -L versions have LCD Display
EJ-1E-D-16 Junior
Temp. Logger, int/ext,-40°C ~ +70°C, 16K $427+GST
3/10
EJ-1E-D-16-L Junior
Temp. Logger, int/ext, -40°C ~ +70°C, 16K, LCD $494
EJ-1E-DC-16
Junior Temperature int./ext. Logger, - 20°C
~ +100°C, 16k $489
EJ-1E-DC-16-L Junior Temp int/ext logger,
-20/+100C, 16K, LCD $543
EJ-1E-DN-16-L
Junior Temperature int./ext. Logger, -100°C~+40°C, 16K $587
EJ-2E data (.pdf file, opens new window)
EJ-2E-C-16 Junior
Temperature external Logger, - 20°C ~ +100°C, 16K $643+GST 3/10
EJ-2E-C-16-L
Junior Temperature external logger, - 20/+100C, 16K, LCD $741
EJ-2E-D-16
Junior Temperature external Logger, - 40°C ~
+70°C, 16K $581
EJ-2E-D-16-L Junior logger, 2 ext.temp, -40°/+70°C,
16K, LCD $660
with LEDs
EJ-HS-B-16
Junior with "B" range air temperature sensor and standard humidity sensor,
IP51, with LEDs
with LEDs and LCD display
EJ-HS-B-16-L Junior with
"B" range air temperature sensor and standard humidity sensor, IP51,
with LEDs and LCD
Jump to separate
page on Temp. & Humidity loggers
Required accessories: Interface
EA-INT, Console Software JA-SWP-WIN
and key ring JA-KEY.
EJ-OE-K1-16
Thermocouple Junior for K-Type
Thermocouple sensor input via adapter, measuring 0°C to 1000°C,
no internal sensor, IP51, 16K, LED's
EJ-OE-K5-16
Thermocouple
Junior for K-Type Thermocouple sensor input via adapter, measuring 0°C
to 500°C,
no internal sensor, IP51, 16K, LED's
EJ-OE-K5-16-L
Thermocouple
Junior for K-Type Thermocouple sensor input via adapter, measuring 0°C
to 500°C,
no internal sensor, IP51, with LEDs and LCD
EJ-OE-M-16-L
Body Temperature Range Junior, 20°C to +45°C, with
LEDs and LCD,
16K memory, IP51
EJ-OE-U-16
Analogue Junior
for recording of power or current via screw terminal adapter, no internal
sensor,
16K memory, IP51, LEDs
EJ-PS-D-16
Pulsecount Junior
for recording pulses, internal D range temperature sensor,
16K
memory, IP51, LEDs
Thermocouple Loggers EJ-OE-K data (.pdf file, opens new window)
Prices:
EJ-OE-K1-16
Junior Thermocouple Logger, 0°C ~ +1000°C, 16K $784+GST
3/10
EJ-OE-K5-16 Junior Thermocouple
Logger, 0°C ~ +500°C, 16K $701
EJ-OE-K5-16-L Junior
Thermocouple logger, 0-500°C, 16K, LCD $803
EJ-OE-U-16
Junior Analogue Input Logger, 0-1V, 0- 20mA,
16K $614
EJ-PS-D-16 Junior Pulsecount Input Logger, -40°C ~ +70°C, 16K $450
Note: these require JA-INT Interface and software (as do all the Escort Juniors), see above.
TE-D-28-KK-30
Thermocouple wire (about 1mm dia) , 30m, with plug, welded junction
exposed $55+GST
TW-T32-TXTW K-type teflon twisted
wire, when purchased with logger, per metre: $6+GST
Also
required with Escort Loggers:
Escort Junior
Interface and Windows software
Interface and Software
to read the data out of an Escort Junior logger
required
for all Escort Junior modules.
EA-INT-U Serial Interface
for Escort Loggers, Universal
has a serial RS-232 connection and
works with
Escort iLog, Junior, Autoclave and Precision loggers
OR
EA-INT-USB Interface
for Escort Loggers, Universal, with USB interface
has a USB connection
and works with
Escort iLog, Junior, Autoclave and Precision loggers
JA-SWP-WIN Software for Escort Data Logger: free download: click here
JA-KEY Escort Keyring magnet to start loggers $44+GST 3/10
HJ-IN-V data (.pdf file, opens new window) See also ACR Nautilus Logger: 10°C to 135°C
HJ-FP-V-16-CI High
Temp Junior logger with two external sensors, both encapsulated (axial probe 60mm
with M6 thread,
radial probe 25mm), stainless steel case, IP68, 16K memory
HJ-IN-V-16-CEI High Temp Junior,
stainless steel case, IP68, internal sensor in encapsulated 80mm stub probe (exchangeable),
16K memory
High Temperature Data
Loggers
HJ-FP-V-16-CI Food Pasteurisation Logger,
Vrange, 16k, SS, 25mmRA/60mmAX.Probes. $1,455+GST 3/10
HJ-IN-V-16-CEI
High Temp.Logger, V range, 16k, SS, 25mm Axial Probe. $1,208
HJ-1E-VZ-16
High Temp. Junior, internal and external sensor, 16K memory,
IP51, LEDs DISCONTINUED
HJ-AC-ZY-2-SI
See more descriptions below.
High Temperature Logger for
ovens and autoclaves rated to 150°C at 5 bar for 30 minutes or 60 minutes
at
normal pressure (if starting from room temperature), external sensor in
50mm stub probe, stainless
steel/PEEK case, IP68, 2K memory DISCONTINUED
HJ-IN-V-16
High Temp. Junior, internal
sensor, 16K memory, IP65, LEDs
HJ-IN-V-16-CI
High Temp Junior, stainless steel case, IP68, internal sensor in 25mm
stub probe (exchangeable), 16K mem $1,045.17
HJ-IN-V-2 High
Temp. Junior, internal sensor, 2K memory. LEDS
HJ-PD-V-16
High Temp. Junior with internal
and encapsulated external sensor for fast response times or immersion, with
LED's,
16K memory DISCONTINUED
HJ-SRV-AC-BAT Battery replacement service for HJ-AC-ZY-2-SI $550.00 8/07 S
HJ-AC-ZY-2-SI
High temperature 150°Autoclave logger
DISCONTINUED
used for
autoclave compliance verification testing. Data
sheet: click here (.pdf file, opens new window)
Logger designed to
sit inside autoclave during operation. Stainless steel. Data
sheet (mfr site)
Pressure and temperature tested to withstand autoclave
temperatures and pressures (up to +150°C / 5 bar).
For further technical
information, see the Autoclave logger.
External rigid stub probe sensor
is used for sampling environment under test.
+25~150°
C, accuracy ±0.5° C, resolution 0.5° C
Stub
probe temperature response T90 of less than 4 minutes in moving air
Internal
sensor measuring range of 150° C used for diagnostic purposes only.
HJ-AC-ZY-2-SI High temperature Autoclave logger. See above for price.
Autoclaves
work by allowing steam to enter, then maintaining the pressure at 103 kPa (15
psi).
This causes the steam to reach 121 °C, and this is maintained for at
least 15 minutes.
Modern autoclaves operate at higher temperature and pressures.
See also ACR Nautilus Logger: 10°C to 135°C
Special Interface Adapter:
JA-INT-SSC Interface Adapter for Stainless Steel Case
Loggers is no longer required.
The Autoclave loggers fit the new versions of
the standard interfaces, see below.
JA-KEY Escort Keyring magnet to start loggers

Also
required with Escort Loggers:
Escort Junior Interface and Windows software
Interface and Software to read the data out of an Escort Junior
logger
required for all Escort Junior modules.
EA-INT-U
Serial Interface for Escort Loggers, Universal
has
a serial RS-232 connection and works with
Escort iLog, Junior,
Autoclave and Precision loggers
EA-INT-USB Interface
for Escort Loggers, Universal, with USB interface
has a USB connection
and works with
Escort iLog, Junior, Autoclave and Precision loggers
JA-SWP-WIN Software for Escort Data Logger: free download: click here
Options:
JA-KEY
Escort Keyring magnet to start loggers $44+GST 3/10
Starting
an Escort Logger without a magnet: click here (jumps to end of this page)
EA-ALK
Escort Alarm Link,
triggers relay output upon
audible alarm of Junior or iLog, resembles interface
JA-BAT-EJH130 Replacement battery for High Temp loggers
Escort User Admin Software
for compliance with the US Food and Drug Admin Title 21, Part 11: Click
here
JA-SWP-CON
Standard software package More
info. $236.85 8/07 Sp
JA-SWP-UAP User Admin Package upgrade from the standard SW package.
More info $POA
ESCORT
Cool Down LoggerEC-OE-C-L Escort Cool Down Logger with
LCD for monitoring of cooling process 2h, 4h and 6h
after falling below +60°C.
Integrated interface (DB9). IP51.
Special software tool required.
JA-SWP-EC Escort Cool Down Logger Software CD
with special software for setting time and preferences for Cool Down Logger,
as well as download and saving of last recorded Cool
Down process.
ESCORT
ThermoCheck TC-MKV ThermoCheck - Portable, handheld temperature meter
and temperature S
Unit
includes rechargeable batteries and interface cable for communication to PC
with attached cable that can be connected to standard 12V /500mA DC Power Adaptor
(not supplied) for battery charging.
TC-MKV
ThermoCheck: $1,462.44 8/07 S
Thermocouple sensor must be ordered separately.
ESCORT ThermoCheck Accessories
TC-DB ThermoCheck data base and communication software for
installing product/location/corrective
action database in ThermoCheck and
downloading recorded data for analysis and record keeping. $251.59
+GST 8/07 Sp
TC-TSN-K0112
K-Type Thermocouple Hypodermic Needle Probe for ThermoCheck $214.55 +GST
8/07 Sp
TC-TSN-K0234 K-Type Thermocouple General Purpose Probe for ThermoCheck
$199.60
TC-TSN-K0454 K-Type Thermocouple Surface
Probe for ThermoCheck $202.03
TC-TSN-K0834 K-Type Thermocouple Air/Between Pack Probe for ThermoCheck
$192.07
TC-TSN-T0112 T-Type Thermocouple Hypodermic Needle Probes
,shaft 60mm,diameter 2mm for ThermoCheck $331.29
TC-TSN-T0234 T-Type
Thermocouple General Purpose Probe shaft 120mm diameter 3mm for ThermoCheck $315.32
TC-TSN-T0454 T-Type Thermocouple Surface Probe,shaft 120mm,diameter
5mm for ThermoCheck $315.32
TC-TSN-T0834 T-Type
Thermocouple Air/Between Pack Probe shaft 120mm,diameter 3mm flat end $319.28

Hazard Analysis and Critical Control Points (HACCP) is a systematic preventive approach to food safety and pharmaceutical safety that addresses physical, chemical, and biological hazards as a means of prevention rather than finished product inspection.
For details see http://en.wikipedia.org/wiki/HACCP
There is no such thing
as HACCAP accreditation or approval for specific equipment.
If applicable, please check the HACCAP manual to see what specifications are appropriate
for your application.
ChartReader for Junior and plastic case High Temp loggers
EJ-CR-MEM
Junior ChartReader for downloading and printing logger data. Memory 1MB, IP51.
Interface to logger attached. PC interface required for data transfer and configuration.
$1,069.95 +GST 8/07 S
JA-CHR-INT-E ChartReader Interface for PC, i.e. PC Interface for ChartReader $49.89 +GST 8/07 Sp
With the juniors and iLogs you can start the logger via programming stage in Console without a magnet.
When you go to Program and Configure
>> select In 0 days
.
option (rather than Wait
.after magnet start).
See
screen shot. This is where you put in a start delay.
On the iLog models, a start delay timer will actually count down on the LCD screen.
On Junior LCD display models, you see: p_ _ _ _ _t on the screen
On iLog LCD display models,
you will
see timer: 0:01 (or whatever the delay is)
On Juniors it will just
count down from internally,
and activation beeps will be heard,
followed by the flashing green active light.
* You have to put some sort of delay in to start the logger. (You can put 1 minute as a minimum).