The ELITEpro SP is a high accuracy poly-phase energy data logger, which measures and records many power parameters.
The PowerScout is a sophisticated power sensor with Modbus RS-485 output connection. It needs to be connected to a data logger / PLC / RTU / etc in order to extract and save the measured data.
Measure, log and analyze electrical
loads to manage energy usage. zwh
The
ELITEpro SP is a recording poly- phase energy meter,
capable of measuring up
to four single-phase loads,
or two three-phase Delta loads, or one three-phase
Wye load.
Ideal for allocating electrical costs by sub-metering process
lines, departments, tenant spaces, or entire buildings.
Includes 4-channels
of current (see current transformers below), and
three channels of voltage (600Vac or 850Vdc line to line).
Patented PhaseChek LED indicators ensure correct CT orientation at installation.
Will
measure, store and report:
Volts, Amps, Amp-Hrs (Ah),
kW, kWh, kVAR, kVARh, kVA,
kVAh, Displacement Power Factor (dPF).
All parameters for
each phase and for system total.
Accuracy: better than 1% (<0.2% typical)
for V, A, kW, kVAR, kVA, PF
Resolution: 0.01 Amp, 0.1 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF
It will calculate harmonics from DC through the 63rd then report
total harmonic distortion (THD), crest factor and peak voltage & current.
Communicate via USB port, internal telephone modem or via wired or wireless
LAN systems.
Prepare baseline studies to identify energy usage and consumption
- 'when and where',
Institute management protocols for conserving energy
based on data,
Measure performance to verify results toward reduced operating
costs,
Integrates with ELOG windows-based software for graphical analysis
and remote data collection.
NEW in 2012
ElitePro SP Data Sheet (5 pages), line-powered – no need for batteries or external power source.
(.pdf file, 877KB, opens in new tab or window, 2/12)
8MB non-volatile memory standard for up to months of recording time.
ElitePro SP Operators Guide & ELOG Software (.pdf file, 3.5MB, opens in new tab or window, 2/12)
ElitePro SP & ELOG Sw Quick Start Guide (.pdf file, 1.4MB, opens in new tab or window, 2/12)
Superceded
ElitePro Data Sheet A4 format, 4 pages portrait (on-screen text is easily readable, and prints well on A4 paper)
(.pdf file, opens in new tab or window)ElitePro Data Sheet A3 folded brochure format, 2 pages landscape (suitable for large screen, needs A3 printer)
(.pdf file, opens in new tab or window)ElitePro Performance Update Sheet - now line powered (.pdf file, opens in new tab or window)
(now standard with all ElitePro loggers sold in Australia.)Notes on line powering the ELITEpro (.pdf file, opens in new tab or window)
When connected to a computer,
a keystroke initiates the capture of one mains cycle: Amps, Volts & KW of
one phase.
This is then analysed up to the 63rd harmonic.
See Notes about ElitePro data storage
ElitePro logger Memory Details
The ElitePro logger has too many variables to be able to provide a quick & easy calculation as to memory capacity in days, hours & minutes.
ELOG software provides a convenient feature that calculates the length of time required to fill the memory for any setup table.
The feature is dynamic, so that any time any parameter in setup table affecting the memory duration is changed, the "Calculated Days Until Memory Exhausted" is updated.
This allows the operator to know in advance how long the memory will last.
The ElitePro Integration period affects the memory capacity. It has
integration periods of 1, 3, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes, & 1, 12, & 24 hours. * More about this below
The ElitePro has four (4) channels each of which will log up to six (6) parameters of volts, amps, kWatts, KVA, P.F. KVAr
Each of these parameters can have four measurements logged for each integration period.
They are min, max,average, instantaneous.
In addition the ElitePro has two (2) virtual summation channels (no external connections).
One of these is typically used to measure totals or averages of the individual phase parameters.
With all 6 channels activated and all parameters selected for min, max, average, & instantaneous,
the ElitePro will log a staggering 144 parameters.
In addition there are alarm settings for each parameter, channel descriptor, and channel comments,
VT ratio, CT ratio, that can be set, all using varying amounts of memory.
* The default integration period is fifteen minutes. The choices are 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20 and 30 minutes; 1 and 12 hours; 1 day.
This tells the logger at what time intervals data is to be stored in the memory.
For example, if the integration period is set for 30 minutes and average watts is being monitored, then every 30 minutes the logger records the average power use (watts) for that channel over the preceding 30 minute interval, based on about 600 measurements of the monitored power draw. If Maximum (and/or Minimum) values are being recorded the highest (and/or lowest) of those 600 readings are also saved.
Price includes Logger, ELOG software, coms cable, high voltage leads, Hi volt alligator clips, instruction manual
Prices do not include GST and may change without notice.
New model:
ElitePro-SP Energy Logger package: $2350+GST 2/12
1.8 Million data storage points, USB interface,
includes Hi Voltage probes, serial coms cable, latest ELOG software & hardcover instruction manual,
8 MB Memory,
Line Power,
USB Cable,
Carrying Case.
See brochure for choice of voltage clips: Croc clips, fused croc clips, shark clips, unterminated leadset, or none.
Also requires current transformers
The ELITEpro comes complete in a carry case, and includes everything required to do a logging audit, except the CTs.
The carry case has enough spare room to include the CTs chosen.
Below is a list of the inclusions in the ELITEpro SP:
1 x ELITEpro SP energy logger
4 x fused high voltage alligator clips
4 x HV high quality silicon leads
1 x USB interface cable
1 x hardcover quick start manual
1 x ELOG11 software CD
1 x 9 volt plug pack wall power supply
1 x Carry case to accommodate logger & all accessories incl. CTs.
Weather Proof Enclosure Kit to protect ELITEpro SP $ 620.00 + GST delivery 14 days.
The following are superceded by the ElitePro-SP above
ElitePro 128K Energy Logger Package
typical use: 15m integration period sampling,
3phase individual phase Amps, Volts, PF & total KW (without max/min) for 31 daysElitePro 512K Energy Logger Package
Selecting a current transformer (pdf, aemc site)
Brochure on Dent Current Transformers (.pdf file, opens in new tab or window)
Prices do not include GST and may change without notice.
Split core Current Transformers for fixed installation ( look like C I ):
0.4" 1cm Opening Data sheet 20amp hinged Data sheet 50amp hinged
CT-HSC-020-U split core hinged current transformer 20 amp $52.00 ea. + GST 3/12
CT-HSC-050-U split core hinged current transformer 50 amp $52.00 ea. + GST
3/4"
1.9cm square opening Data sheet
CT-SCS-005A (small) split core current transformer 5
amp $ 125.00 ea. +GST 2/12
CT-SCS-015A (small) split
core current transformer 15 amp $ 125.00 ea. +GST
CT-SCS-050A (small)
split core current transformer 50 amp $ 125.00 ea. +GST
CT-SCS-100A
(small) split core current transformer 100 amp $ 125.00 ea. +GST
1" opening
New CT, (the small white one you see in the EP-SP brochure) -
Data sheet 100amp hinged Data sheet 200amp hinged
CT-HMC-100-U split core hinged current transformer 100 Amp, 25mm: $85+GST 2/12
CT-HMC-200-U split core hinged current transformer 200 amp $ 85.00 + GST
1.25"
square opening Data sheet
CT-SCM-100A (medium) split core current transformer 100
amp $ 155.00 ea. +GST
CT-SCM-200A (medium) split core current transformer
200 amp $ 155.00 ea. +GST
CT-SCM-400A (medium) split core current transformer
400 amp $ 155.00 ea. +GST
CT-SCM-600A (medium) split core current transformer
600 amp $ 155.00 ea. +GST
2" square opening Data sheet
CT-SCL-600A
(large) split core current transformer 600 amp $ 195.00 ea. +GST
CT-SCL-800A
(large) split core current transformer 800 amp $ 195.00 ea. +GST
High
accuracy split core suitable for secondary current monitoring
CT-SHS-005A
high accuracy split core transformer 5 amps $ 295.00 ea. +GST
CT-SHS-015A
high accuracy split core transformer 15 amps $ 295.00 ea. +GST
Clamp-on
handheld tongs with spring Data sheet 150amp 500amp 1000amp
CT-CON-0150A clamp-on current transformer
150 amps $ 332.00 ea. +GST
CT-CON-0500A clamp-on current transformer
500 amps $ 395.00 ea. +GST
CT-CON-1000A clamp-on current transformer
1000 amps $ 485.00 ea. +GST
Output 1 to 333mVAC, 1Class
1, 1% accuracy
Flexible Current Transformers 91cm length Data sheet
CT-FLN-3000A flexible Rowgoski dual range current transformer 300/3000 amps $
795.00 ea. +GST 2/12
CT-FLN-6000A flexible Rowgoski dual range current transformer
600/6000 amps $ 980.00 ea. +GST
These do not require external power.
Data
on CT-FLN-3000A (.pdf file, opens in new tab or window)
RoCoil
mV current transformers - Rogowski Coil
The DENT RoCoil mV Flexible
Current Transformers have been designed for
accurate measurement of AC current
with a safe, millivolt output.
These require external power, see below for
details.
Data
on RoCoil mV (.pdf file, opens in new tab or window)
RoCoil Specs RoCoil mV Specs Rogowski Appnote Rogowski_Principles_AppNote
ELITEpro SP
The following four items are only for use with new ELITEpro SP
CT-R16-1310 flexible RoCoil current transformer 5000 amps @ $ 175.00 + GST 2/12
CT-R24-1310 flexible RoCoil current transformer 5000 amps @ $ 221.00 + GST
CT-R36-1310 flexible RoCoil current transformer 5000 amps @ $ 310.00 + GST
CT-R72-1310 flexible RoCoil current transformer 5000 amps @ $ 495.00 + GST
The older ElitePro models only accept CT's with a 0-333mV output. Hence all of the above Split Core and Clamp-On Current Transformers can be used with the older ElitePro models.
The 300/3000 Amp and 600/6000 Amp Rogowski coils which have a built-in battery powered preamplifier can also be used.
In addition the RoCoil CT's below are also suitable for the older ElitePro but require external power via the CT-INTER-BOX.
Rogowski Coil Current
Transformers (only for use with older ElitePro 128K & 512K)
Rogowski Coil Current
Transformers have no metal cores which make them extremely flexible and light
weight.
Because they lack a metal core, Rogowski coils have very low phase
shift error, can be used on very high currents, and are suitable for highly distorted
AC waveforms.
These "rope" style CTs are designed to take measurements where
standard current sensors cannot.
The following 5 items are only for use with older ElitePro 128K & 512K
CT-RMV-16-1000 flexible RoCoil current transformer 1000 amps $ 345.00 +GST 2/12
CT-RMV-24-2000 flexible RoCoil current transformer 2000 amps $ 395.00 +GST
CT-RMV-36-3000 flexible RoCoil current transformer 3000 amps $ 515.00 +GST
CT-RMV-72-6000 flexible RoCoil current transformer 6000 amps $ 685.00 +GSTAlso required:
CT-INTER-BOX interface box to connect RoCoils together $ 185.00 ea. +GST
These provide power to the RoCoil transformers above.
The ELITEpro's DC power output is only available when running in "line powered" mode.
To operate in "line powered" mode, the ELITEpro's voltage probes must be connected to a circuit (as per the .pdf sheet).Notes on line powering the old model ELITEpro (pdf file, opens in new tab or window) superceded.
Otherwise a separate plug pack (5 to 24VDC out, 30mA max per coil) must be used to power the RoCoils.
Networked Power MetersDependable Instruments for Precise Energy Measurement
Dent's PowerScout™ Series networked power meters are submetering devices designed to provide timely and accurate consumption data necessary to gain the upper hand on electrical costs in today's escalating energy market.
These meters can capture kWh/kW energy and demand data as well as virtually all relevant energy parameters for diagnostics and monitoring on three-phase or single phase circuit installations.
The PowerScout's™ flexibility, size, and ease-of-use make them ideal tools for gathering detailed consumption information in commercial, industrial, government and retail environments.
The PowerScout is not a data logger, but a sophisticated power sensor with Modbus RS-485 output connection.
It needs to be connected to a data logger / PLC / RTU / etc in order to extract and save the measured data.Data loggers that can connect to the PowerScout include the Datataker DT80 series,
and the RLog (please enquire) which also provides remote data upload via GSM/GPRS (emailed or via remote web server).Also note that the PowerScout needs its voltage terminals to be wired up to the mains by a licensed electrician – it is powered from these terminals, and also takes voltage measurements from them. It does not come with voltage leads & probes.
By comparison, the ElitePro (described above) has an internal battery, so it can be used with or without the voltage connections (see info on line powered feature). It comes with fused voltage leads and alligator clips.
Industry Standard Communications
Communications to the PowerScout™ is through an RS-485 serial connection, 9600bps, using the industry standard Modbus protocol.
Up to 254 PowerScout™ meters may be connected to a single RTU or datalogger for monitoring and recording power usage at
multiple locations within a single site.
DENT's proprietary ViewPoint™ software utility allows you to easily configure the PowerScout™ for the connected CTs and to check readings.
Technical Specifications
Service Type: Single Phase, Split Phase, Three Phase, Three Phase Delta, Four Wire (WYE)
Power: From L1 Phase to Neutral Wire. 0.5 Watts; Internal fuse protection
3 Voltage Channels: 60-600 Volts AC, Higher AC voltages can be measured with a Potential (voltage) Transformer
3 Current Channels: 0-5,000+ Amps depending on current transformer
Measurement Type: True RMS using high-speed digital signal processing (DSP)
Line Frequency: 50 and 60Hz
Waveform Sampling: 13 kHz voltage and current
Measurements: Volts, Amps, kW, kWh, kVAR, kVARh, kVA, kVAh
Apparent Power Factor (aPF)
Displacement Power Factor (dPF)
All parameters for each phase and for system total
Accuracy: Better Than 1% (<0.5% typical) for V, A, kW, kVAR, kVA, PF excluding sensor
Resolution: Adjustable, 0.1 Amp, 0.1 Volt, 1 watt, 1 VAR, 1 VA, 0.01 Power Factor typical
Indicators:
3 LEDs for setup, 1 per phase: Green when voltage and current on the on the same phase, Red when incorrectly wired
(PhaseChek™, patent pending), a 4th LED for Power On and communication indication
PowerScout Brochure - including current transformers PS18-N PowerScout™ 18 (circuit board only)
PS18-D PowerScout™ 18 (indoor enclosure)
PS3-D PowerScout™ 3 (indoor enclosure, pictured above right)
Current Transformers are ordered separately
PowerScout's™ Flexible Choice of Current Transformers
All DENT current transformers are internally shunted and, therefore, inherently safe
compared to other commercially available CTs.
Choose from three types: Split-Core, RōCoil™ and Clamp-On (not pictured).

| High Accuracy SHS-0005 |
Small Split Core SCS-0050, SCS-0100 |
Medium Split Core SCM-0100, -0200, SCM-0400, -0600 |
Large Split Core SCL-0600, 1000 |
RōCoil™ R16, R24, R36 |
|
| Window size | 1.0 cm (0.4") | 1.9 cm (.75") | 3.2 cm (1.25") | 5.1 cm (2.0") | 16": 13 cm (5.") 24": 19 cm (7") 36": 26 cm (10") |
| Output signal | 333mV at 5A | 333mV at50A, 100A | 333mV at 100, 200, 400, 600 A |
333mV at 600, 1000A | 131mV/1000A @ 60 Hz 110mV/1000A @ 50 Hz |
| Useful current range | 0.05-7 Amps | 5-65, 10-130 Amps | 10-130, 20-260, 40-520, 60-780 Amps |
60-780, 100-1200 A | 0-3500 Amps (PowerScout™) 15-20,000A (depending on meter compatibility) |
See PowerScout Brochure - including current transformers for details
Keycode: zwh
Free Phone Consultation!
Call Now: +61 2 9481 7420
Email: (JavaScript required)